PRODUCT DATASHEETS
Base Grille Water
Filtration
System
Model WF-NL240/NL240
Capacity 240 Gallons (908 Liters)
Model WF-L400/L400
Capacity 400 Gallons (1514 Liters)
Tested and certified
by NSF International
against ANSI/NSF
Standard
42 for the reduction
of Chlorine Taste and Odor,
Particulate
Class II*; and against ANSl/NSF
Standard
53 for the
reduction
of Lead.
This system has been tested according to ANSl/NSF 42/53 for the reduction of the substances
listed below. The concentration
of
the indicated substances
in water entering the system was reduced to a concentration
less than or equal to the permissible limit for
water leaving the system, as specified in ANSI/NSF 42/53.
Substance
Reduction
NSF Reduction
Average
Influent Challenge
Maximum
Average
Minimum %
Average %
Aesthetic Effects
Requirements
Influent
Concentration
Effluent
Effluent
Reduction
Reduction
Chlorine Taste/Odor
_>50%
2.0 mg/L _+10%
0.05 mg/L
0.05 mg/L
97.4%
97.4%
Particulate Class II*
At least 10,000
100,000/mL**
88.0%
40,667/mL
95.1%
833,333/mL
_85%
1.9 mg/L
particles/mL
Contaminant
NSF Reduction
Average
Influent Challenge
Maximum
Average
Minimum %
Average %
Reduction
Requirements
Influent
Concentration
Effluent
Effluent
Reduction
Reduction
Lead: @ pH 6.5
0.01mg/L
0.15 mg/L***
0.15 mg/L _+10%
0.001 mg/L
0.001 mg/L
99.3%
99.3%
0.003 mg/L
mg/L
97.9%
Lead: @ pH 8.5
0.01 mg/L
0.15 mg/L***
0.15 mg/L _+10%
0.001
99.0%
Test Parameters:
pH = 7.5 + 0.5 unless
otherwise
noted.
Flow = 0.5 gpm
(1.9 Lpm). Pressure
= 60 psig (413.7 kPa). Temp. = 63°F
(17.2°C).
It is essential that operational, maintenance,
and filter
replacement requirements be carried out for the product to
perform as advertised.
Model WF-NL240:
Change cartridge at least every 6 months.
Use replacement
cartridge NL240, part #4396508.
2005 suggested retail price of $32.99 U.S.A./S44.95 Canada.
Prices are subject to change without notice.
Model WF-L400: The filter monitor system measures the
amount of water that passes through the filter and alerts you
to replace the filter. When 90% of the filter's rated life is used,
the filter indicator light changes from green to yellow. When
100% of the filter's rated life is used, the filter indicator light
changes from yellow to red, and it is recommended
that you
replace the filter. Use replacement cartridge L400, part
#4396508. 2005 suggested retail price of $32.99 U.S.A./
$44.95 Canada. Prices are subject to change without notice.
The product is for cold water use only.
Do not use with water that is microbiologically
unsafe or of
unknown quality without adequate disinfection before or after
the system.
Refer to the front cover or "Assistance
or Service" section for
the Manufacturer's
name, address and telephone number.
Refer to the "Warranty" section for the Manufacturer's
limited
warranty.
Application Guidelines/Water Supply Parameters
Water Supply
City or Well
Water Pressure
30 - 120 psi (207 - 827 kPa)
Water Temperature
33 ° - 100°F (0.6 ° - 37.8°C)
Service Flow Rate
0.5 gpm (1.9 Lpm) @ 60 psi.
* Class II particle size: >1 to <5
** Test requirement
is at least 100,000 particles/mL
of AC Fine Test Dust.
*** These contaminants
are not necessarily in your water supply. Performance
may vary based on local water conditions.
® NSF is a registered trademark
of NSF International.
12