Euphonix System 5 Operation Manual page 56

Digital audio mixing system
Hide thumbs Also See for System 5:
Table of Contents

Advertisement

System 5 Digital Audio Mixing System Operation Manual
Changing Sample Rate
To change the sample rate, you must first activate a Mixer Model with the desired sam-
ple rate as described in the previous section.
1.
Change the sample rate of the studio master digital sync generator.
This must be done before changing the Sync Source on the DF64 digital cores.
This makes it easier to tell when the controller cards are set to the correct Sync
Source option.
2. Locate the controller card in each DF64. Each card has a section labeled Sync
Source with a recessed button allowing cycling through the sync options; a pa-
per clip can be used to press the button.
3.
Select the required sync source and sample rate. The 1x modes are used for 44.1
and 48 kHz, and the 2x modes are for 96 kHz.
The order is:
4.
Power off the console, pilots, and digital cores and reboot.
AES 1x
Word 1x
Internal 44.1
Internal 48
AES 2x
Word 2x
Internal 96
56