Fedders Split System Air Conditioner Installation & Operation Manual

Fedders Split System Air Conditioner Installation & Operation Manual

1.5 through 5 ton split system air conditioner

Advertisement

Installation, Operation and Maintenance
1.5 Through 5 Ton
Split System Air Conditioner

TABLE OF CONTENTS

INTRODUCTION ..............................................................................1
NOTES TO INSTALLER ....................................................................1
CODES ............................................................................................1
INSPECTION AND UNPACKING ......................................................1
Clearances ..........................................................................2
Support ..............................................................................2
Exposure ............................................................................2
Proximity to Evaporator....................................................2
ELECTRICAL CONNECTIONS ..........................................................2
Braze Joints ..............................................................................3
Evacuation ................................................................................3
Opening the Service Valve (Step Valve) ................................3
CONNECT REFRIGERANT PIPING ..................................................4
Precautions ................................................................................4
Liquid Line Sizes........................................................................4
Suction Line Sizes......................................................................4
SUBCOOLING CHARGING ............................................................5
OPERATION INSTRUCTIONS ..........................................................5
MAINTENANCE INSTRUCTIONS ....................................................5
CONDENSING UNIT NOMENCLATURE ..........................................6
LIMITED WARRANTY ....................................................................7
NOTE:
THESE INSTRUCTIONS ARE INTENDED AS AN AID TO QUALIFIED
SERVICE PERSONNEL FOR PROPER INSTALLATION, ADJUSTMENT
AND OPERATION OF THIS EQUIPMENT. READ THE ENTIRE
INSTRUCTION MANUAL THOROUGHLY BEFORE ATTEMPTING
INSTALLATION OR OPERATION.

Advertisement

Table of Contents
loading

Summary of Contents for Fedders Split System Air Conditioner

  • Page 1: Table Of Contents

    Installation, Operation and Maintenance 1.5 Through 5 Ton Split System Air Conditioner TABLE OF CONTENTS INTRODUCTION ...1 NOTES TO INSTALLER ...1 RECOGNIZE SAFETY SYMBOLS, WORDS AND LABELS ...1 CODES ...1 INSPECTION AND UNPACKING ...1 INSTALLATION Clearances ...2 Support ...2 Exposure ...2 Proximity to Evaporator...2...
  • Page 2: Introduction

    INTRODUCTION You have made a major investment in a fine piece of equipment. Keep your investment sound by reading these instructions before installing this unit. This will ensure that the full potential of this equipment is achieved. It will also be helpful in avoiding any needless service costs or operational problems.
  • Page 3: Installation

    INSTALLATION Condensing Unit Location The condensing unit should be located outdoors as close as possible to the evaporator. Consider the following factors: Clearances The air inlet should be located at least 12" from a wall or other obstruction for unrestricted air flow. The air outlet should be located so as to direct discharged air away from the building.
  • Page 4: Service Valve Connections Braze Joints

    Electrical Connections (cont.) Connect Control Wiring 1. Route 24 volt control wires through control wiring grommet and connect leads to control wiring. 2. Use No. 18 AWG color coded, insulated wire. If thermostat is located more than 100 ft. from unit, as measured along the control voltage wires, use No.
  • Page 5: Connect Refrigerant Piping

    CONNECT REFRIGERANT PIPING The following guidelines should be followed when installing refrigerant piping. Comply with all local, state, and federal codes and/or regulations pertaining to this type of equipment and its installation. Run the tubing by the most direct route and support every few feet.
  • Page 6: Subcooling Charging

    Model OPERATION INSTRUCTIONS 1. If the furnace and air conditioner are on separate thermostats, turn the furnace thermostat off during the cooling season to prevent simultaneous operation of the heating and cooling systems. Reverse the procedure during the heating season.
  • Page 7: Condensing Unit Nomenclature

    Chassis Size B = 21 1/2” W x 21 1/2” D x H C = 29 1/2” W x 29 1/2” D x H Brand F= Fedders Fitting Type V = Sweat Electrical Designation 1 = 208/230 Volts, 1 Phase, 60 Hz...
  • Page 8: Limited Warranty

    LIMITED WARRANTY LIMITED FIVE YEAR WARRANTY: Fedders will provide a replacement part or component that proves to be defective in material or workmanship. WARRANTY LIMITATIONS: • Limited Warranty does not include allowances for labor or travel expense connected with the installation of...

This manual is also suitable for:

C18abd1vfC24abd1vfC36acd1vfC48acd1vfC60acd1vfC30abd1vf ... Show all

Table of Contents