Download Print this page

Maytag 3RMED4905TW0 Use & Care Manual page 8

Electric
Hide thumbs Also See for 3RMED4905TW0:

Advertisement

Available languages

Available languages

Installation
spacing
for
recessed
area or closet
installation
The following
spacing
dimensions
are recommended
for this dryer. This dryer has been tested
for spacing
of 0 cm (0") clearance
on the sides and rear. Recommended
spacing
should
be
considered
for the following
reasons:
Additional
spacing
should
be considered
for ease of installation
and servicing.
Additional
clearances
might be required
for wall,
door and floor
moldings.
Additional
spacing
should
be considered
on all sides of the dryer to reduce noise transfen
For closet installation,
with
a door, minimum
ventilation
openings
in the top and bottom
of the door are required.
I ouvered
doors with equivalent
ventilation
openings
are
acceptable.
Companion
appliance
spacing
should
also be considered.
45.7 cm*_
_1_
*'t_
2.5cm
68.6 cm 2.5cm
(1 ")
(27")
(1")
A
_,[
3b.scm"
Ig
1(14 max)
÷1 I_
2.5 cm* 74.3 c m 12.7 c m
(1")
(29_ ")
(5")
B
310 c m 2.- _
-
(48 in!)
24cm 2.
(155in_.)
- NNNN_I_
A. Recessed
area
B. Side view - closet
or confined
area
C. Closet door
with
vents
*Additional
spacing
recommended
m
7.6cm*
(3" o re)
{
7.6cm*
_- 13' cml
[
IMPORTANT:
Observe
all governing
codes and ordinances.
It is your
responsibility
1o contact
a qualified
electrical
installer
to assure that the electrical
installation
is
adequate
and is in conformance
with
all local codes and ordinances.
[b supply
the required
2 wire, single phase, 230 volt, 50 Hz., AC only electrical
supply
on a separate 30-amp
circuit.
A time-delay
fuse or circuit
breaker is recommended.
Connect
to an individual
branch
circuit.
NOTE: In accordance
with
the European
EMC Directive
(89/336/EEC)
the maximum
electricity
supply
system impedance
to which
the electric
dryer should
be connected
is
declared
to be 0.302
Ohm
+ j0.189
Ohm.
Electrical
Shock
Hazard
Electrical
earthing
is required
on this
dryer.
Do net earth
to a gae pipe.
Do not change
the power
supply
cord plug. if it does
not fit the outlet,
have
a proper
outlet
installed
by a
qualified
electrician.
Do not have
a fuse
in the neutral
or earthing
circuit.
Do not use an extension
cord
with
this
dryer.
Check
with
a qualified
electrician
to be sure
the dryer
is
properly
earthed.
Do not connect
plug
end of power
supply
cord
into a
live receptacle
before
connecting
power
supply
cord
to
dryer
terminal
block.
Do not reuse
old power
supply
cord.
Failure
to follow
these
instructions
could
result
in
death,
fire, or serious
injury.
lb minimize
possible
shock hazard,
the cord must be plugged
into a mating
receptacle.
Be sure wall
receptacle
is within
reach of dryer's final location.
8

Advertisement

loading