Important
Safety
Instructions°°
ooooooooooooooooooooooooooooo
Electrical
Shock
Hazard
1. Plug unit
only into grounded
electrical
outlet.
2. Do not use an extension
cord or plug adaptor
with
this unit.
3. Do not operate
unit with filter removed.
Failure to follow
the above precautions could result in
electrical shock, fire or personal injury,
If the dehumidifier
has a serial plate rating of 115 volts
and up to and including
7.5 amps the unit may be on
a fuse or circuit
breaker
with other
devices.
However, the
maximum amps of all devices on that fuse or circuit breaker
can not exceed the amps of the fuse or circuit breaker.
Notice
Do not operate
this dehumidifier
without
proper
time
delay circuit
protection.
Refer to serial plate for proper
power
supply
requirements.
RECOMMENDED
CIRCUIT
WIRE SIZES
(As installed
per
building
code)
PROTECTOR
SIZE
WIRE GAUGE
15 AMP
#14
MINIMUM
20 AMP
#12
MINIMUM
30 AMP
#10
MINIMUM
@©©@
I I5V
230V
230V
230V
15A
15A
20A
30A
For Your Safety:
Do not store
or use gasoline
or other
flammable
vapors
and liquids
in the vicinity
of this or any other
appliance.
The fumes
can create a fire hazard
or explosion.
Power Supply:
Outlet Requirement:
Grounding
Type:
Minimum Wire Size:
Circuit Protector:
llSV,
60HZ
AC Only 1-Phase
3-Prong
125 V, 1S Amp
#14 (A.W.G.)
3-Wire
Use Copper Wire
Only
15 Amp Time Delay Fuse
or Circuit
Breaker
important
Grounding
Requirements
Your Dehumidifier
will operate on any 115 volt, 3-pronged
(grounded),
60 Hz circuit. A separate line is not required, but
it is advisable not to overload the circuit with heavy duty
appliances
such as washing machines,
etc. For your safety,
this dehumidifier
is equipped with a 3-pronged,
grounding
plug and must be plugged into a properly grounded
outlet
(Figs. 1 & 2). If your outlet is not of the proper type, it is your
responsibility
to have the outlet and wiring changed to the
correct type. DO NOT cut off the third (grounding)
prong.
DO NOT USE AN ADAPTER.
Grounded
three-prong
wall receptacle
Three-prong
grounding plug >
_
Single outlet
grounding
wall receptacle
Close Windows
and Doors
To assure
efficient
dehumidification,
close
all windows
and
doors
in the
area
where
the
dehumidifier
is to
operate
(Fig.3).
Plug In
Once
you
have
assembled
your
dehumidifier
and
installed
it in an appropriate
location,
plug the cord into
a properly
grounded
outlet
as indicated
in the electrical
requirement
(Fig. 4).
Important:
If the unit has been transported or stored in any
position
other than upright, you should wait three
hours before strarting unit