Troubleshooting - LG LUV300 Owner's Manual

Hide thumbs Also See for LUV300:
Table of Contents

Advertisement

Available languages

Available languages

TROUBLESHOOTING
Review this chart to find do-it-yourself
solutions for minor performance problems.
Any service or repair needed, other than as described in this User's Guide, should be performed through
_our local LGE service center.
, WARNING
Electrical
shock
and personal
injury
hazard.
Always
unplug
the vacuum
cleaner
before
servicing.
Failure
to do so could
result
in electrical
shock
or personal
injury.
Vacuum cleaner will
. Unplugged at wall outlet
. Make sure cord is plugged into a functioning
outlet.
not run
. Batteries are dead
. Replace batteries. [See page 19]
. Thermal protector activated
. Allow the vacuum cleaner to cool down.
[See page 14]
Poor dirt pickup
. Full or clogged dust tank
. Dust tank improperly installed
Agitator
does not
turn
Dust escapes
the
dust tank
Cleaner
picks up
moveable
rugs or is
hard to push
Agitator
on pet hair
turbine
tool will not
run when attached
o Clogged hose or wand
. Belt broken/not installed properly
o Agitator motor overload protection
activated
. Hole in hose
. Worn agitator
. Use lower power level
. Switch is off (unit is in bare floor
mode)
. Cleaner is in upright position
. Agitator motor overload protection
is tripped (brush is jammed)
• Belt broken
. Dust tank improperly installed
. The dust tank lid not closed
• The bottom plate is not latched
. Wrong pile height setting
. Dirty agitator or agitator supports
. Obstruction
in turbine air path
• Low suction from vacuum cleaner
. Main wand still connected to body
base
. Empty dust tank and clean filters. [See page 16-17]
. Make sure all dust tank components
and filters are
installed correctly.
. Check for clogs. [See page 19-20]
. Check belt and replace if needed. [See page 18-19]
. Unplug the vacuum cleaner and check the agitator for
obstructions.
Press the reset button. [See page 14]
. Inspect hose carefully. Replace if needed.
. Contact service.
. Increase the power level. [See page 10]
. Turn on agitator power switch. [See page 10]
. Press the Body release and tilt unit back.
[See page 10]
. Unplug the vacuum cleaner and check the agitator for
obstructions and reset the unit. [See Page 14]
• Replace belt. [See page 18-19]
° Make sure all dust tank components
and filters are
installed correctly.
° Check the dust tank lid.
• Make sure the bottom plate is closed and latched.
° Adjust pile height. [See page 11]
° Clean the inside of the pet hair turbine tool.
[See page 18]
° Clean the inside of the pet hair turbine tool.
[See page 18]
° Check for clogs. [See page 19-20]
Accessory
has no
. Remove wand. [See page 13]
suction when using
with the handle
Handle controls
not
. Batteries need replacement
. Replace batteries in handle. [See page 19]
working
Dust tank feels
. This is normal
. The vacuum is designed like this prevent the tank from
loose when lifting by
separating from the main body while carrying.
the carry handle.

Advertisement

Table of Contents
loading

Table of Contents