Appendix B Installation Procedure; Creation Of Logical Disks; Binding Logical Disk - NEC S1400 NF1400-SR40E User Manual

Disk array unit
Table of Contents

Advertisement

Appendix B Installation Procedure

1. Creation of Logical Disks

The logical disk must be created according to your environment before using the disk array unit.
The following procedure is required to create a logical disk.
Bind the logical disk.

1.1 Binding Logical Disk

To create a logical disk, 2-step procedure consisting of POOL bind and LD bind is required.
The POOL bind requires the specification of a RAID type. Select the RAID type carefully because it
has certain influences on system performance and capacity. See Section 2.6 "RAID Configuration" for
details.
The LD bind requires the specification of capacity. The specified capacity defines the number of
logical disks in a single POOL. Select the capacity carefully because the unused area remaining may
affect the performance on the capacity. See "3. Logical Disk Capacity" in Appendix A for details.
See "Individual Settings (Bind/Unbind of Logical Disk)" in "NEC Storage Series Configuration
Guide" for the use of the management software (WebSAM NEC Storage Manager).
B-1
F

Advertisement

Table of Contents
loading

Table of Contents