Whirlpool GZ25FSRXYY0 User Instructions page 19

Table of Contents

Advertisement

Available languages

Available languages

Interior Water Filtration System
Model UKF8001AXX-200
Capacity
200 Gallons (757 Liters)
(_
System tested and certified
by NSF International
against
NSF/ANSI
Standard
42 for the reduction
of
Chlorine
Taste and Odor, Particulate
Class I*; and against
NSF/ANSI
Standard
53 for the reduction
of
Lead, Mercury, Atrazine,
Benzene,
p-Dichlorobenzene,
Carbofuran,
Toxaphene,
Cysts,
Turbidity,
Asbestos,
O-Dichlorobenzene,
Ethylbenzene,
Chlorobenzene,
Endrin, Tetrachloroethylene
and Lindane.
This system
has been tested
according
to NSF/ANSI
Standards
42 and 53 for the reduction
of the substances
listed
below.
The
concentration
of the indicated
substances
in water
entering
the system
was reduced
to a concentration
less than or equal to the
permissible
limit for water
leaving
the system,
as specified
in NSF/ANSI
Standards
42 and 53.
Substance
Reduction
NSF Reduction
Average
Influent Challenge
Maximum
Average
Minimum%
Average%
Aesthetic
Effects
Requirements
Influent
Concentration
Effluent
Effluent
Reduction
Reduction
Chlorine Taste/Odor
50% reduction
2.00 mg/L
2.0 mg/L _+10%
0.06 mg/L
**
0.050625 mg/L
97.00%
97.52%
Particulate Class I*
85% reduction
14,000,000 #/mL
At least 10,000
370,000 #/mL
196,666 #/mL
97.40%
99.00%
particles/mL
Contaminant
NSF Reduction
Average
Influent Challenge
Maximum
Average
Minimum%
Average%
Reduction
Requirements
Influent
Concentration
Effluent
Effluent
Reduction
Reduction
Lead: @ pH 6.5
0.010 mg/L
0.150 mg/U
0.15 mg/L + 10%
< 0.001 mg/L
< 0.001 mg/L
>99.30%
>99.30%
Lead: @ pH 8.5
0.010 mg/L
0.150 mg/U
0.15 mg/L _+10%
< 0.001 mg/L
< 0.001 mg/L
>99.30%
>99.30%
Mercury: @ pH 6.5
0.002 mg/L
0.006 mg/L
0.006 mg/L + 10%
0.0005 mg/L
0.0003 mg/L
91.70%
95.00%
Mercury: @ pH 8.5
0.002 mg/L
0.0059 mg/L
0.006 mg/L _+10%
0.0018 mg/L
0.00073 mg/L
69.20%
88.10%
Benzene
0.005 mg/L
0.0133 mg/L
0.015 mg/L _+10%
0.0005 mg/L
0.0005 mg/L
96.10%
96.30%
p-Dichlorobenzene
0.075 mg/L
0.210 mg/L
0.225 mg/L _+10%
< 0.0005 mg/L
< 0.0005 mg/L
>99.80%
>99.80%
Carbofuran
0.040 mg/L
0.0753 mg/L
0.08 mg/L _+10%
0.027 mg/L
0.008 mg/L
64.60%
73.45%
Toxaphene
0.003 mg/L
0.015 mg/L
0.015 _+10%
< 0.001 mg/L
< 0.001 mg/L
>93.3%
>93.3%
Atrazine
0.003 mg/L
0.0102 mg/L
0.009 mg/L _+10%
0.0027 mg/L
0.00105 mg/L
76.30%
89.40%
Asbestos
>99%
126.5 MF/L
107to 108fibers/L t_
< 0.17 MF/L
< 0.17 MF/L
>99.99%
>99.99%
Live Cysts _
>99.95%
122,500 #/L
50,O00/L min.
< 1 #/U
< 1 #/U
>99.99%
>99.99%
Turbidity
0.5 NTU
10.5 NTU
11 _+1 NTU
0.30 NTU
0.125 NTU
97.30%
98.80%
Lindane
0.0002 mg/L
0.0019 mg/L
0.002 _+10%
< 0.00016 mg/L
0.000035 mg/L
91.80%
97.90%
Tetrachloroethylene
0.005 mg/L
0.015 mg/L
0.015 mg/L _+10%
< 0.0005 mg/L
< 0.0005 mg/L
>96.6%
>96.6%
O-Dichlorobenzene
0.6 mg/L
1.7 mg/L
1.8 mg/L _+10%
< 0.5 mg/L
< 0.5 mg/L
>99.9%
>99.9%
Ethylbenzene
0.7 mg/L
2.2 mg/L
2.1 mg/L _+10%
0.0048 mg/L
0.11 mg/L
99.80%
99.90%
Chlorobenzene
0.1 mg/L
2.0 mg/L
2.0 mg/L _+10%
0.0038 mg/L
0.0008 mg/L
99.80%
99.90%
Endrin
0.002 mg/L
0.007 mg/L
0.006 mg/L _+10%
0.0004 mg/L
0.0002 mg/L
94.30%
96.80%
Test Parameters:
pH = 7.5 _+0.5 unless
otherwise
noted.
Flow = 0.55 gpm
(2.08 Lpm). Pressure
= 60 psig (413.7
kPa).
5°F (20°C + 3°C).
It is essential
that operational,
maintenance,
and filter
replacement
requirements
be carried
out for the product
to
perform
as advertised.
The disposable water filter should be replaced at least every
6 months.
The filter monitor system measures the amount of water that
passes through the filter and alerts you to replace the filter.
When 90% of the filter's rated life is used, the yellow (Order)
light comes on. When 100% of the filter's rated life is used, the
red (Replace) light comes on, and it is recommended
that you
replace the filter. For models without filter status lights,
replace the filter every 6 months. Use replacement filter
model UKF8001AXX-200.2011
suggested retail price of
$44.99 U.S.A./S49.95 Canada. Prices are subject to change
without notice.
The product is for cold water use only.
Do not use with water that is microbiologically
unsafe or of
unknown quality without adequate disinfection before or after
the system. Systems certified for cyst reduction may be used
on disinfected waters that may contain filterable cysts.
Temp. = 68°F _+
Refer to the "Water Filtration System" section for the
Manufacturer's
name and telephone number.
Refer to the "Warranty" section for the Manufacturer's
limited
warranty.
Application
Guidelines/Water
Supply
Parameters
Water Supply
City or Well
Water Pressure
35 - 120 psi (241 - 827 kPa)
Water Temperature
33 ° - 100°F (1 o _ 38oC)
Service
Flow Rate
0.55 gpm
(2.08 L/min.)
@ 60 psi
*Class I particle size: >0.5 to <1 um
**Test requirement
is at least 100,000 particles/mL
of AC Fine Test Dust.
tThese contaminants
are not necessarily in your water supply. Performance may vary based on local water conditions.
ttFibers greater than 10 um in length
_Based on the use of Cryptosporidium
parvum oocysts
® NSF is a registered trademark
of NSF International.
19

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gz25fdrxyy0Wrx735sdbm00

Table of Contents