Downdraft Vent (cont.)
wire.
Power supply
wiring is not
provided.
oonn_tor
white
conduit
connector
1171
supply
CaDle
Thread the power supply cable through the
conduit connector. Tighten the screws on the
conduit connector.
Disconnect power supply,
Connect the two white wires together with twist-
on wire connector.
Connect the black wire from the power supply
cable to the black wire of the control with a twist-
on wire connector.
Connect the three green ground wires together
with a twist-on on wire connector.
Attach the wiring box to the
front of the blower box under
the control using the four
screws removed in Step 2.
19-
.
.
Numbers
correspond
to
steps.
11.
If downdraft vent is being installed in a separate
cutout, it may have to be lifted out of the opening
a few inches to do this.
19 }
Turn power supply on. Place control
knob securely over stem. Check the
operation of the blower and speed
control. If one does not operate, disconnect
power source and check that wire connections
have been made correctly.
20•,
Insert grease filter and place gdllein
1
J position.
If downdraft vent is installed between two
appliance.,
attach a support brace to each side
of the downdraft ventcover.
f
To get the most efficient
use from your
new downdraft
vent, read the Use and
Care information
section
on the back
cover. Keep Installation
Instructions
and Use en_Care
Guide close by for, I
easy reference.
'!
18