Kenmore 110,84182 Use & Care Manual page 6

240-volt compact electric dryer
Hide thumbs Also See for 110,84182:
Table of Contents

Advertisement

Available languages

Available languages

Installation
Clearances
The location must be large enough to allow the dryer door to
open fully.
Dryer Dimensions
31 "t
(79.7
cm)
L
*Most installations require a minimum 51/2 '' (14.0 cm) clearance
behind the dryer for the exhaust vent with elbows. See "Venting
Requirements."
Minimum
installation
spacing for recessed area and closet
installation
The following dimensions shown are for the minimum spacing
allowed when the unit is to be operated with, or without, the
Stack Stand Kit. To purchase a Stack Stand Kit, please call
1-800-4-MY-HOME
®(1-800-469-4663).
Additional spacing should be considered for ease of
installation and servicing.
Additional clearances might be required for wall, door, and
floor moldings.
Additional spacing of 1" (2.5 cm) on all sides of the dryer is
recommended
to reduce noise transfer.
For closet installation with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are
acceptable.
Companion appliance spacing should also be considered.
Recessed or closet installation - Dryer only
114"
(35.6cn"
,-1_1
(7.6crn)
A
19"(49J_
0"-_-I'_'-
"-_-I'_'-0"
(ocm)
(ocm)
B
A. Side view - closet or confined area
B. Recessed area
Recessed or closet installation - Stacked
12" Z
(30.5cm)
DRYER
12" _
(3&5 cm)
WASHER
m
0"..-_1_,_ .- ..-=,q4-0"
(o era)
(o era)
A
m
m
1" ..-D,- I I"_--
(2.5cm)
B
A. Recessed area
B. Side view - closet or confined area
C. Closet door with vents
(154.9 cm2)
L
3"
(7.¢cm)
t
Mobile Home - Additional
Location Requirements
This dryer is suitable for mobile home installations. The
installation must conform to the Manufactured
Home
Construction
and Safety Standard, Title 24 CFR, Part 3280
(formerly the Federal Standard for Mobile Home Construction
and Safety, Title 245, HUD Part 280).
Mobile home installations require:
Metal exhaust system hardware which is available for
purchase from your local Sears store or Sears Service Center.
Special provisions must be made in mobile homes to
introduce outside air into the dryer. The opening (such as a
nearby window) should be at least twice as large as the dryer
exhaust opening.
It is your responsibility
To contact a qualified electrical installer.
To be sure that the electrical connection is adequate and in
conformance
with the National Electrical Code, ANSl/NFPA
70-latest edition and all local codes and ordinances.
The National Electric Code requires a 4-wire supply
connection for homes built after 1996, dryer circuits involved
in remodeling after 1996, and all mobile home installations.
A copy of the above code standards can be obtained from:
National Fire Protection Association, One Batterymarch
Park,
Quincy, MA 02269.
To supply the required 3 or 4 wire, single phase, 120/240-volt,
60-Hz., AC-only electrical supply (or 3 or 4 wire, 120/208-volt
electrical supply, if specified on the serial/rating
plate) on a
separate 30-amp circuit, fused on both sides of the line. A
time-delay fuse or circuit breaker is recommended.
Connect
to an individual branch circuit. Do not have a fuse in the
neutral or grounding circuit.
Do not use an extension cord.
If codes permit and a separate ground wire is used, it is
recommended
that a qualified electrician determine that the
ground path is adequate.