Base Grille Water Filtration System
Model WF-LC400V/LC400V
Capacity
400 Gallons
(1514 Liters)
(_
System
tested and certified
by NSF International
against
NSF/ANSI
Standard
42 for the reduction
of Chlorine
Taste and Odor, Nominal Particulate
Class I*;
and against
NSF/ANSl
Standard
53 for the reduction
of Lead, Mercury,
Atrazine,
Benzene,
Toxaphene,
p-dichlorobenzene,
2, 4-D, Cysts, Turbidity
and
Asbestos.
This system has been tested according to NSF/ANSl Standards 42 and 53 for the reduction of the substances
listed below. The
concentration
of the indicated substances in water entering the system was reduced to a concentration
less than or equal to the
permissible
limit for water leaving
the system,
as specified
in NSF/ANSI
Standards
42 and 53.
Substance
Reduction
NSF Reduction
Average
Influent Challenge
Maximum
Product
Minimum %
Average %
Aesthetic
Effects
Requirements
Influent
Concentration
Effluent
Water
Reduction
Reduction
Chlorine Taste/Odor
_>50%
2.1 mg/L
2.0 mg/L _+10%
0.06 mg/L
0.05 mg/L
97.1%
97.6%
Nominal Particulate Class I*
_>85%
5,366,667/mL
Atparticles/mLleast
10,000
4,100/mL**
2,300/mL
99.3%
99.9%
Contaminant
NSF Reduction
Average
Influent Challenge
Maximum
Product
Minimum %
Average %
Reduction
Requirements
Influent
Concentration
Effluent
Water
Reduction
Reduction
Lead: @ pH 6.5
0.01 mg/L
0.16 mg/L1-
0.15 mg/L _+10%
0.001 mg/L
0.001 mg/L
99.3%
99.35%
Lead: @ pH 8.5
0.01 mg/L
0.15 mg/L1-
0.15 mg/L _+10%
0.001 mg/L
0.001 mg/L
99.2%
99.31%
Mercury: @ pH 6.5
0.002 mg/L
0.0061 mg/L
0.006 mg/L _+10%
0.0004 mg/L
0.0003 mg/L
93.5%
96.7%
Mercury: @ pH 8.5
0.002 mg/L
0.0057 mg/L
0.006 mg/L _+10%
0.0008 mg/L
0.00051 mg/L
85.8%
91.2%
Benzene
0.005 mg/L
0.0138 mg/L
0.015 _+10%
0.0005 mg/L
0.005 mg/L
96.3%
96.3%
o-dichlorobenzene
0.075 mg/L
0.220 mg/L
0.225 _+10%
0.0005 mg/L
0.0005 mg/L
99.7%
99.7%
Toxaphene
0.003 mg/L
0.014 mg/L
0.015 _+10%
0.0014 mg/L
0.001 mg/L
90%
92.96%
Atrazine
0.003 mg/L
0.009 mg/L
0.009 mg/L _+10%
0.0013 mg/L
0.00036 mg/L
85.6%
85.6%
2, 4-D
0.07 mg/L
0.197 mg/L
0.215 _+10%
0.058 mg/L
0.0137 mg/L
70.6%
93.06%
Asbestos
99%
26 x 107
107to 10_fibers/Ll-1 -
0.18 x 107 mg/L
0.18 x 107 mg/L
99.93%
99.93%
Cysts$
99.95%
111,000/mL
50,000/L min.
1 mg/L
1 mg/L
99.99%
99.99%
Turbidity
0.5 NTU
11.08 NTU
11 _+1 NTU
0.13 NTU
0.078 NTU
98.8%
99.3%
Test Parameters: pH = 7.5 _+0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure =
Temp. = 63°F (17.2°C).
It is essential that operational, maintenance, and filter
replacement requirements be carried out for the product to
perform as advertised.
Flush for 5 minutes prior to use.
Model WF-LC400V:
The filter monitor
system
measures
the
amount
of water that passes
through the filter and alerts you to
replace the filter. When 90% of the filter's rated life is used, the
filter indicator
light changes
from green to yellow. When 100% of
the filter's rated life is used, the filter indicator
light changes
from
yellow to red, and it is recommended
that you replace the filter.
Use replacement
cartridge
LC400V, part #9010. 2007 suggested
retail price of $39.99 U.S.A. Prices are subject to change without
notice.
The product
is for cold water use only.
Do not use with water that is microbiologically
unsafe or of
unknown
quality without
adequate
disinfection
before or after the
system.
Systems
certified
for cyst reduction
may be used on
disinfected
waters
that may contain
filterable
cysts.
Refer to the front cover or "Accessories"
section
for the
Manufacturer's
name, address and telephone
number.
60 psig (413.7 kPa).
Refer to the "Warranty"
section
for the Manufacturer's
limited
warranty.
Note that while the testing
was performed
under standard
laboratory
conditions,
actual
performance
may vary.
Application
Guidelines/Water
Supply
Parameters
Water Supply
City or Well
Water Pressure
30 - 120 psi (207 - 827 kPa)
Water Temperature
33 ° - 100°F (0.6 ° - 37.8°C)
Service
Flow Rate
0.5 gpm (1.89 L/min.)
@ 60 psi
*Class I particle size: >0.5 to <1 um
**Test requirement
is at least 100,000 particles/mL
of AC Fine Test Dust.
1-These contaminants
are not necessarily in your water supply. Performance
may vary based on local water conditions.
1-1-Fibers greater than 10 um in length
SBased on the use of Cryptosporidium
parvum oocysts
® NSF is a registered trademark
of NSF International.
24