TROUBLESHOOTING
CHART #5
CHART4
CHART4
YES
_
YES
POSSIBLY
MIXTURE
TOO LEAN!
CHECK
GAS LINES DOWNSTREAM
OF GAS
VALVE FOR BLOCKAGE.
ARE GAS LINES CLEAR?
IS GASNENTURI
VALVE
CORRECT
SIZE?
SEE REPAIR PARTS DIAGRAM.
YES
POSSIBLY
MITURE
TOO RICH!
CHECK
FLUE PASSAGES
IN BOILER PER
"MAINTENANCE
AND CLEANING".
ARE
FLUE
PASSAGES
IN BOILER CLEAN?
,_YES
CHECK MIXER AND BURNER
FOR
BLOCKAGE
PER MAINTENANCE
AND
CLEANING
INSTRUCTIONS.
ARE AIR
PASSAGES
IN MIXER AND BURNER
CLEAN?
r
4,
CHECK
AIR ORIFICE
AT BURNER
INLET
FOR CORRECT
SIZE. SEE REPAIR PARTS
DIAGRAM.
IS ORIFICE
CORRECT
SIZE?
CLEAN/REPLACE
GAS LINES.
BE SURE TO USE CORRECT
GASNENTURI
VALVE SIZE.
CLEAN BOILER FLUE PASSAGES
PER MAINTENANCE
AND CLEANING
INSTRUCTIONS
CLEAN MIXER AND BURNER
PER MAINTENANCE
AND
CLEANING
INSTRUCTIONS
REPLACE
BURNER
I
DOES MAIN BURNER
RUN UNTIL CALL FOR
HEAT ENDS OR HI
LIMIT AQUASTAT
CONTACTS
OPEN?
CHART6
NO #1
NO#2
NO#3
7
* IF THE ANSWER
IS NO.
CHOOSE
THE APPROPRIATE
PATH (#1, #2, OR #3) BASED ON
SYMPTOMS
SHOWN.
CHART
6
CHART 6
7
RUNS SMOOTHLY
FOR ABOUT
6
SECONDS
THEN SHUTS OFF.
INDICATES
POOR
FLAME SIGNAL.
CHECK
IGNITER/SENSOR
POSITION.
TIP SHOULD
BE
SLANTED
TOWARDS
BURNER
,YES
CHECK
FLAME SIGNAL >0.6uA?
CONSULT
BOILER MFGR. FOR
SPECIFIC
INSTRUCTIONS.
REQUIRES
SPECIAL
TOOLS.
,YES
REPLACEIBC
NO_
RESTORE
NO
IGNITER/SENSOR
TO CORRECT
POSITION.
DO NOT RELOCATE.
J
OXIDE COATING
ON
IGNITER PREVENTING
FLAME SIGNAL.
REPLACE
IGNITERJSENOR,