1. Consult localwater treatmentspecialistfor wa-
ter treatmentrecomendations if your waterpH lev-
els are belowof 7.0 or hardnessis above 7 grains
hardness.
a. This boileris designedfor use in a closed
hydronicheatingsystemONLY!
b. Excessivefeedingof fresh make-up
water
to the boiler may lead to premature
failure
of
the boiler sections.
2. Use clean fresh tap water for initial fill and peri-
odic make-up
of boiler.
a. A sand filter must be used if fill and make-
up water from a well is to be used.
b. Consideration
should be given to cleaning
the heating
system,
particularly
in retrofit sit-
uations,
where a new boiler is being installed
in an older piping system.
c. In older
systems,
obviously
discolored,
murky, or dirty water, or a pH reading
below
7, are indications
that the system
should
be
cleaned.
d. A pH reading between
7 and 8 is preferred.
3. Antifreeze,
if needed, must be of a type specifically
designed
for use in closed hydronic heating systems
and be compatible
with type 356 T6 aluminum
at op-
erating temperatures
between 20°F and 250°F.
a. Use of antifreeze
must be in accordance
with local plumbing
codes.
b. Pure
glycol
solutions
are very corrosive,
therefore
hydronic
system
antifreeze
typi-
cally
contains
corrosion
inhibitors.
Different
brands
of hydronic
system antifreeze
contain
different
types
of corrosion
inhibitors.
Some
brands
have corrosion
inhibitors
that break
down
more rapidly
or become
ineffective
at
higher
temperatures
when
used with alumi-
num. This could
lead to premature
failure
of
the aluminum
boiler.
Consult
the antifreeze
manufacturer
on the
compatibility
of their
product
with aluminum.
c. Follow
the antifreeze
manufacturer's
in-
structions
on determining
proper ratio of an-
tifreeze
to water
for the expected
low tem-
perature
conditions,
and for maintaining
the
quality of the antifreeze
solution from year to
year. Improperly
maintained
antifreeze
solu-
tions will gradually
lose their ability to protect
the aluminum
boiler from corrosion.
d. The recommended
premixed
antifreeze
solution
is
INTERCOOL
NFP-50.
This
product is sold direct to distributors
by the
antifreeze
manufacturer.
Please
contact In-
terstate Chemical
Company,
New York Cus-
tomer Service at 1-800-422-2436
or your dis-
tributor for more information.
Use of an alternate
manufacturer's
premix
antifreeze
is acceptable
if the product
speci-
fications
are comparable
with those
of the
recommended
premix antifreeze
and the an-
tifreeze
is compatible
with type 356 T6 alu-
minum.
Use of incompatible
antifreeze
could
damage
the heat exchanger
and will void the
product warranty.
The antifreeze
must
be maintained
per the
specifications
of the manufacturer.
Failure
to
do so will result in the warranty
being voided.
Follow the antifreeze
manufacturer's
instruc-
tions on determining
the proper
ratio of an-
tifreeze
to water
for the expected
low tem-
perature
conditions
and for maintaining
the
antifreeze
solution from year to year.
e. DO NOT USE AUTOMOTIVE
ANTIFREEZE,
as the type of corrosion inhibitors used will coat
the boiler's heat transfer surfaces and greatly re-
duce capacity and efficiency.
f. Use of antifreeze
in any boiler will reduce
heating
capacity
by as much
as 10-20%,
due to differing
heat transfer
and pumping
characteristics.
This must be taken into con-
sideration
when
sizing the heating
system,
pump(s)
and expansion
tank.
Consult
anti-
freeze
manufacturer's
literature
for specific
information
on reduced
capacity.
g. Water content of the boiler is 2,6 gallons
(10 liters).