4 Place in operation t heappliance beinginspected. Follow
the lightinginstructions. Adjustthermostat so appliance
willoperate continuousl_z
5. Testfor spillage atthe drafthoodreliefopening after5
minutes o fmainburner o peration. Use theflame ofa match
or candle, or smoke froma cigarette, cigaror pipe
6. Afterit hasbeendetermined t hateachappliance remain-
ing connected to the common ventingsystem properly
vents when testedas outlinedabove,return doors,
windows, exhaust fans,fireplace dampers andanyother
gas-burning a ppliance totheirprevious c onditions o fuse
7 Any_mproper operation of the common ventingsystem
shouldbecorrected sothe installation conforms w iththe
National Fuel GasCode, ANSI Z 223.1 -latest revision. When
resizing anyportionof the common venting system, t he
common venting system shouldbe resized to approach
the m_n_mum sizeas determined usingthe appropriate
tablesin Part11 in the National FuelGasCode,ANSI
Z223.1 -latest r ewsion.
For boilers for connection
to gas vents or chimneys,
vent installations
shall be in accordance with Part 7,
Venting of Equipment,
of the National Fuel Gas Code,
ANSI Z223.1-1atest
revision and applicable provisions
of the local building codes,
Vent connectors
serving appliances vented by natural
draft shall not be connected into any portion of mech-
anical draft systems operating under positive pressure.
ROOF
RIDGE
3/4 HT MAXIMUM
HT
MUST
SLOPE
UP
AT LEAST
1/4 INCH
PER FOOT
OF
HORIZONTAL
RUN
HORIZONTAL INSTALLATION
TO FURNACE
VENT
TO CHIMNEY
OR BOILER
DAMPER
INSTALL VENT DAMPER WITH
ACTUATOR
TO SIDES OF
VENT ONLY, DO NOT MOUNT
ABOVE OR BELOW VENT.
VERTICAL INSTALLATION
TO CHIMNEY
[_
FLOW
VENT
DAMPER
ACTUATOR
MAY BE
TO FURNACE N
INSTALLED
IN ANY POSITION
OR BOILER
U
TYPICAL
INSTALLATION
FOR VENT DAMPER
NOTE CAUTION
AND FOOTNOTES
1. Install the vent damper to service only the single appliance for
which it is intended, ff improperly installed,a hazardous condition,
such as an explosion or carbon monoxide poisoning, could result.
2. Do not install the vent damper on vent pipe curve.
3. DO not run wiras near high temperature surfaces. Use stand-off
brackets it necessary