ADDiTiONAL THINGS YOU SHOULD KNOW
Now that you understand
the basic operation
functions, here are more control features
with which you should became
familiar.
The "cool" circuit has an automatic
3 minute time delayed
start if the unit is turned off and on quickly. This prevents
overheating
of the compressor
and possible circuit breaker
tripping.
The fan will continue to run during
this time.
There is a 2-Second
delay
for the compressar
shutting dawn when selecting
FAN ONLY/HEAT.
This is to cover the
possibility
of having
to roll through to select another
mode.
The control will maintain
the set temperature
within 2 degrees
Fahrenheit,
between
60°F and 90°F (in cool mode),
55°F and 80°F (in heat mode).
The control is capable
of displaying
temperature
in degrees
Fahrenheit
or degrees
Celsius. To convert
from one to the
other and back, press and hold bath the "TEMP/TIMER"
Up(A)
and Dawn (v)
buttons for 3 seconds.
FAULTCODES :
If the display reads "HS", "ES" or "AS", a sensor has failed. Contact 1 -800-4-MY-HOME®
for repair.
Heat sensor
Evaporator
coil sensor
Air temperature
sensor
AUTO RE-START :
After
a power outage, the unit will remember
the last setting and return the unit to the same setting
once power is restored.
FRESH AiR VENT CONTROL
( On 253.79184
model )
1. Pushed In (Fig. 1) - Recirculates inside air
2. Partially
Pulled Out (Fig. 2) - Draws fresh air into room
3. Fully Pulled Out (Fig. 3) -
Exhausts air from room and draws fresh
air into room
Figure 1 (VENT CLOSED )
Figure 2 ( VENT OPEN )
Figure 3 ( VENT & EXHAUST OPEN )