T & P Valve And Pipe Insulation; Temperature Pressure Relief Valve - Kenmore 153.339111 HA Owner's Manual

Power miser 9 gas water heater
Table of Contents

Advertisement

Property
Damage
Hazard
, Avoid water
heater damage
• Install thermal
expansion
tank if necessary.
Do not apply heat to cold water inlet
Contact
qualified
installer
or Sears
Service
CenteL
Figure
15 shows
the typical
attachment
of the water
piping
to
the water
heater.
The water
heater
is equipped
with
3/4" NPT
water
connections.
INSTALLATmON COMPLETED
US{NG
mNSTALLATION K{T
FLEXIBLE
WATER
CONNECTORS
HOT WATER
COLDWATER
OUTLET
INLET
l
t
SHUTOFF
VALVE
THREADED
TO
THREADED
TO
flexible
connectors,
connect
the cold water
pipe to the cold
water
inlet of the water
heater.
NOTE:
This
water
heater
is super
insulated
to minimize
heat
moss from
the tank.
Further
reduction
in heat
loss
can
be accomplished
by insulating
the
hot water
lines
from
the water
heater.
T & P Valve and Pipe _nsu_ation
Remove
insulation
for T & P valve
and pipe connections
from
carton.
PBPE
_NSULATUON
FLUE PIPE
DRAFTHOOD
FIGURE15.
NOTE:
mfusing
copper
tubing,
solder
tubing
to an adapter
before
attaching
the
adapter
to the
cold
water
inlet
connection.
Do not somder the cold water
suppmy mine directly
to the cored water
inlet.
It will harm
the dip tube
and damage
the tank.
Look at the top cover
of the water
heater. The water
outlet is
marked
"HOT".
Put two or three turns
of teflon
tape around
the threaded
end of the threadedoto-sweat
coupling
and
around
both
ends
of the 3/4" NPT
threaded
nipple.
Using
flexible
connectors,
connect
the hot water
pipe
to the hot
water
outlet
on the water
heater.
Look at the top of the water
heater.
The cold water
inlet is
marked
"COLD".
Put two or three turns of teflon tape around
the threaded
end of the threadedoto-sweat
coupling
and
around
both
ends
of the 3/4" NPT
threaded
nipple.
Using
FIGURE 15A.
Fit pipe insulation
over the incoming
cold ,water line and the hot
water
line.
Make
sure
that
the insulation
is against
the top
cover
of the heater.
Fit T & P valve insulation
over valve. Make sure that the insulation
does
not interfere
with the lever of the T & P valve.
Secure
al! insulation
using tape.
Temperature-Pressure
Relief Valve
13
Expmosion Hazard
• Temperature-pressure
relief valve
must comply
with ANSi
Z21.22
and ASME code.
• Properly
sized
temperature-
pressure
relief
valve
must
be
installed in opening provided.
• Can result
in overheating
and
excessive
tank pressure•
• Can cause serious injury or death•
This
heater
is provided
with
a properly
certified
combination
temperature
- pressure
relief valve
by the manufacturer.
The
valve
is certified
by a nationally
recognized
testing
laboratory
that maintains
periodic
inspection
of production
of
listed
equipment
of materials
as meeting
the requirements
for
Relief Valves
and Automatic
Gas Shutoff
Devices
for Hot Water
Supply
Systems,
ANSI
Z21.22
and the code
requirements
of
ASME.