,_,_,A,,._Y Precautions - Kenmore 153.336152 Owner's Manual

Gas water heater
Table of Contents

Advertisement

Safety
Precautions
I
_,WARNING
1
Improper
installation,
adjustment,
alteration,
service or |
maintenance
can cause DEATH,
SERIOUS
BODILY /
INJURY, OR PROPERTY
DAMAGE.
Refer to this manu- /
al for assistance
or consult
your local Sears Service|
Center
for further information.
/
_,WARNING
WATER
HEATERS
EQUIPPED
FOR ONE TYPE
GAS
ONLY:
This water
heater
is equipped
for one type gas
only. Check the model rating
plate near the gas contrel
valve for the correct
gas. DO NOT USE THIS WATER
HEATER
WITH
ANY
GAS OTHER
THAN
THE ONE
SHOWN
ON THE MODEL
RATING
PLATE. Failure to
use the correct gas can cause problems which can result in
DEATH,
SERIOUS
BODILY
INJURY,
OR PROPERTY
DAMAGE.
If you have any questions or doubts consult
your gas supplier or local utility.
_,WARNING
INSTALLATIONS IN AREAS WHERE FLAMMABLE LIQ-
UIDS (VAPORS) ARE LIKELY TO BE PRESENT OR
STORED (GARAGES, STORAGE, AND UTILITY AREAS,
ETC): Flammable liquids (such as gasoline, solvents,
propane (LP) or butane, etc.), all of which emit flammable
vapors, may be improperly stored or used in such areas.
The gaswater heater pilot light or main burner can ignite
such vapors. The resulting flashback and fire can cause
death or serious burns to anyone in the area, as well as
property damage.
If installation in such areas is your only option, then the
installation must be accomplished in a way that the pilot
flame and main burner flame are elevated from the floor
at least 18 inches. While this may reduce the chances of
flammable vaporsfrom a floor spill being ignited, gasoline
and other flammable substancesshouldnever be stored or
used in the same room or area containing a gas water
heater or other open flame or spark producingappliance.
NOTE: Flammable vapors may be drawn by air currents
from other areas of the structure to the appliance.
_WARNING
If this water heater will be used in beauty shops, barber
shops, cleaning establishments,
or self-service laundries
with dry cleaning equipment,
it is imperative
that the
water heater or water heaters be installed so that com-
bustion and ventilation
air be taken from outside these
areas. Refer to the "Locating
The New Water
Heater"
section of this manual and also the latest edition of the
National Fuel Gas Code, ANSI Z223.1, also referred to as
NFPA 54 for specifics provided concerning air required.
AWARNING
A fire can start if combustible materials such as clothing,
cleaningmaterials, or flammable liquidsare placedagainst
or next to the water heater.
AWARNING
At the time of manufacture
this water heater was pro*
vialed with a combination
temperature-pressures
relief
valve certified
by a nationally recognized
testing labora-
tory that
maintains
periodic inspect.lon of production of
listed equipment
or materials,
as meeting the require-
ments
for
Relief Valves
and Automatic
Gas Shutoff
Devices for Hot Water
Supply Systems, and the latest
edition
of ANSI
Z21.22
and the code requirements
of
ASME.
If replaced,
the valve must meet the require-
ments of local codes, but not less than a combination
temperature
and pressure relief valve certified as meet-
ing the requirements
for Relief Valves and Automatic
Gas Shutoff
Devices
for Hot Water
Supply Systems,
ANSI Z21.22 by a nationally
recognized
testing laborato-
ry that maintains
periodic
inspection
of production
of
listed equipment
or materials.
The valve must be marked with a maximum
set pressure
not to exceed the marked
hydrostatic working pressure
of the water
heater
(150 Ibs./sq. in.) and a discharge
capacity
not less than the water
heater
input rate as
shown on the model
rating
plate.
(Electric
heaters
-
watts divided by 1000 x 3415 equal BTU/Hr. rate.)
Your local jurisdictional
authority,
while mandating
the
use of a temperature-pressure
relief
valve complying
I with ANSI Z21.22 and ASM, E, may require
a valve model
different from the one furnished with the water heater.
Compliance
with such local requirements
must be satis-
fied by the installer or end user of the water heater with
a locally prescribed
temperature-pressure
relief
valve
installed in the designated opening in the water heater in
place of the factory furnished valve.
For safe operation
of the water heater, the relief valve
must not be removed
from it's designated
opening or
plugged.
The temperature-pressure
relief valve must be installed
directly into the fitting of the water heater designated for
the relief valve. Position the valve downward and provide
tubing so that any discharge will exit only within 6 inches
above, or at any distance below the structural floor. Be
certain
that no contact
is made with any live electrical
part. The
discharge
opening must
not be blocked
or
reduced
in size under
any circumstances.
Excessive
length, over 30 feet, or use of more than four elbows can
cause restriction
and reduce
the discharge capacity of
the valve.
No valve or other obstruction
is to be placed between
the relief
valve and the tank. Do not connect
tubing
directly to discharge drain unless a 6" air gap is provided.
To prevent bodily injury, hazard to life, or property dam-
age, the relief valve must be allowed to discharge water
in quantities
should circumstances
demand.
If the dis-
charge pipe is not connected to a drain or other suitable
means, the water
flow may cause property
damage.
The Discharge Pipe:
Must not be smaller in size than the outlet pipe size of
the valve, or have any reducing
couplings or other
restrictions.
Must not be plugged or blocked.
Must be of material listed for hot water distribution.
Must be installed so as to allow complete
drainage of
both the temperature.pressure
relief
valve, and the
discharge pipe.
Must terminate
at an adequate drain.
Must not have any valve between the relief valve and
tank.
2

Hide quick links:

Advertisement

Table of Contents
loading