ICP 84 Series Operating And Maintenance Instructions Manual
ICP 84 Series Operating And Maintenance Instructions Manual

ICP 84 Series Operating And Maintenance Instructions Manual

84 series sizes 007-015 packaged terminal air conditioner with electric heat and heat pump units

Advertisement

Quick Links

CONTENTS
Page
PRODUCT INFORMATION ...........................
1
INTRODUCTION
...................................
1
SAFETY CONSIDERATIONS
.........................
1
UNIT INSPECTION
................................
1 3
I. Front Panel .................................
2
ELECTRICAL
DATA ...............................
3,4
...................................
3
II. Voltage Supply ..............................
4
INSTALLATION ...................................
4-6
I. Chassis Installation ..........................
4
Installation ...................
6
.....................................
7,8
I. Comfort Controls ............................
7
II. Operating Controls ..........................
7
III. Operating Modes ............................
8
........................
8,9
I. Indoor-Air Inlet Filters ........................
8
II. External Parts ...............................
8
III. Internal Parts ...............................
9
PREVENTATIVE
MAINTENANCE
.....................
9
..............................
10
ACCESSORIES ...................................
11
WARRANTY
.....................................
12
FOR SERVICE
CALL TOLL-FREE
1-877-875-3362
IMPORTANT:
Read
entire
installation
instructions
before
installing
unit.
PRODUCT INFORMATION
If you have problems
or questions
concerning
your Air" Con-
ditioner
or Heat
Pump
unit,
you will
need
the
following
information.
Model and serial numbers
are on tire nameplate
of the cabinet.
Model No.
Serial No.
Date of Purchase
Dealer's
Address
Dealer's
Phone Number
Cancels:
OM 84 07 1
OM 84 07 2
4/15/03
INTRODUCTION
The
84
series
of packaged
terminal
air
conditioning
units
(PTAC)
offers
3 units:
842
cooling
unit,
840 cooling
unit
with
electric
heat
and
841
heat
pump
unit
with
electric
heat.
Units
are
available
in 4 different
capacity
sizes:
7000,
9000,
12,000,
and
15,000
Btuh.
Units
are
available
in 208/230
and
265 voltages.
SAFETY CONSIDERATIONS
The 84 series
PTAC traits meet
strict
safety
and
operating
standards.
It is important
to install
or service
the system
so
it operates
safely
and
efficiently
For safe installation
and
trouble-free
operation,
carefully
read
the
Installation
Instructions
before
beginning.
Follow each installation
step
exactly
as shown.
Observe
all local, state,
and national
dec-
trical
codes.
Pay close attention
to all warning
and caution
notices given in this manual.
The Warning
symbol
refers
to a hazard
or unsafe
practice
which
can result
in severe
personal
injury
or death.
The
Caution
symbol
refers
to a hazard
or unsafe
practice
which
can result
in personal
injury or product
or property
damage.
The information
in these
instructions
is applicable
for most
sites
and
maintenance
conditions.
It is recom
mended
that
this
unit
be installed
properly
by qualified
installation
technicians
in accordance
with
the Installation
Instructions
provided
with the unit,
IMPORTANT:
Before
installation,
check that
the voltage
of
the electric
supply
is the same
as the voltage
shown
on the
nameplate.
UNIT INSPECTION
Examine
unit for" damage
incurred
during
shipment.
File a
claim
immediately
with
the transit
company
if damage
is
found.
The data
information
plate
(Fig. 1), located
on fi'ont of unit
under
front
panel,
lists
the model
numbeL
voltage
ranges,
and other" important
electrical
information
about
this prod
uct. Reading
and understanding
this material
is important
for proper
use of this unit.
To access
the information
plate,
the front panel
must be removed;
see Fig. 2.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 84 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for ICP 84 Series

  • Page 1: Table Of Contents

    Cancels: OM 84 07 1 OM 84 07 2 4/15/03 CONTENTS INTRODUCTION Page series of packaged terminal conditioning units (PTAC) offers 3 units: cooling unit, 840 cooling unit with PRODUCT INFORMATION ......electric heat heat pump unit with electric heat. INTRODUCTION ........
  • Page 2: Front Panel

    I. FRONT PANEL MODEL 840ADXO12003AAAA To remove fl'ont panel: SERIAL 2802X77609 Grasp panel firmly near" bottom of both sides. DATE OF HFG 07°08°02 Pull panel forward then upward to release magnetic VOLT RANGE 239-292 latches partition hooks. VOLTS NOTE: Front panel be secured to chassis...
  • Page 3: All Units

    84 0 A Series Designation Chassis Options PTAC (Packaged Terminal Air Conditioner) AA - Standard CP - Corrosion Protection ModeU RC - Wall Thermostat Control (Not available 2 - Cooling Only on cooling only units) RP - Wall Thermostat Control with 0 - Cooling with Electric...
  • Page 4: Voltage Supply

    II. VOLTAGE SUPPLY Table 3 -- Retrofit Wall Sleeves Check voltage supply at outlet. For satisfactory results, MANUFACTURER WALL SLEEVE PART NUMBER voltage range must always be within the ranges found on the Metal Sleeve GAB71 General Electric data information plate (Fig.
  • Page 5 BOTTOM SEAL VENT SHIPPING VENT DOOR Fig. 7 -- Remove Bottom Seal from GE Plastic Sleeve DOOR TAPE CABLE Fig. 9 -- Location of Shipping Tape on Vent Door B. Install Chassis in Sleeve (See Fig. 8-11) 1. Inspect foam gaskets (top, bottom,...
  • Page 6: Wall Thermostat Installation

    NOTE: Terminal connector be removed replaced MANUFACTURER simplify thermostat wiring. MOUNTING HOLES Connect wires fl'om terminals on the thermostat © terminals on chassis terminal board connector. CARRIER/BRYANT Fig. 13 and _AMANA/TRANE Reinstall cover'. ©WARNNG ° Set desired fan speed using fan switch (unit will...
  • Page 7: Operation

    OPERATION VENT HANDLE IMPORTANT: When unit is first started, high humidity con- ditions can cause condensation to form on discharge grille, Keep doors windows closed. When room humidity decreases, the moisture will evaporate. MAGNET I. COMFORT CONTROLS A. Adjust Airflow Direction The discharge air grille is mounted...
  • Page 8: Operating Modes

    B. Outdoor Thermostat (Heat Pump Units Only) If the setscrew is left at the factow setting (in the heat pump M 0 [)I position), unit will operate in the reverse cycle heating [[ H!>[ RA [kJkl mode. Fig. 16. When temperature of the outdoor...
  • Page 9: Internal Parts

    III. INTERNAL PARTS Internal parts should be cleaned at least once during year. The outdoor vent filter should be cleaned at least once during a cooling or heating season. Internal parts that should be cleaned include the following {see Fig. 8, 20, and 21): •...
  • Page 10: Troubleshooting

    TROUBLESHOOTING POSSIBLE CAUSES SOLUTIONS UNIT DOES NOT START Unit may have become unplugged • Check that plug is securely in wall receptacle. Fuse may have blown • Replace the fuse. See Note 1. Circuit breaker may have been tripped • Reset circuit breaker. See Note 1. Unit mode dial may be set to the OFF position •...
  • Page 11: Accessories

    ACCESSORIES ACCESSORY FORM NUMBER PART NUMBER DESCRIPTION 42-SLEEVE-1 Non-Insulated Plastic Wall Sleeve, 1 per pack 52S-48SI 42-1NSUL-1PK Insulated Plastic Wall Sleeve, 1 per pack 52S-50SI 42-STEEL-1 PK Insulated Metal Wall Sleeve, 1 per pack Wall Sleeves 52S-49S1" 42-EXT24-1 PK Extended Metal Wall Sleeve for Deep Wall Applications (24 in, deep), 1 per pack Friedrich wall sleeve extension to retrofit PTAC unit into Friedrich 111/2-in.
  • Page 12: Installation

    84 Series Packaged Terminal Air Conditioner Warranty CAC/BDP WILL NOT BE RESPONSIBLE FOR: FULL ONE-YEAR WARRANTY -- During the first year after purchase, CAC/BDP will, through its authorized independent servicing dealers or service stations*, CLEANING REQUIRED PRIOR TO WARRANTY REPAIR. free of charge to the user or subsequent users, repair or replace any parts which Standard...

This manual is also suitable for:

840adxo12003aaaa

Table of Contents