Custom Control Tmswitch; Clearing Blockages; Lubrication; Emptying Dirt Cup - Hoover SAVVY U8155-900 Owner's Manual

Hide thumbs Also See for SAVVY U8155-900:
Table of Contents

Advertisement

Lubrication
The cleaner is equipped
with bearings
that contain sufficient lubrication
for the
life of the cleaner. The addition of lubri-
cant could cause damage. Therefore,
do not add lubricant to any bearings.
Thermal
protector
An internal thermal protector has been
designed
into your cleaner to protect it
from overheating.
When the thermal
protector activates,
the suction motor will stop running,
however the agitators
will continue to
run. If this happens, proceed as follows:
1. Turn the cleaner OFF and discon-
nect it from the electrical outlet.
2. Check dirt cup pre-filter, HEPA
cartridge filter and final filter for dirt
accumulation.
3. Refer to "Clearing blockages"
section.
4. When the motor cools, the thermal
protector automatically
resets and
cleaning may continue.
If the thermal protector continues to
activate after following the above steps,
your cleaner may need servicing (see
"Service" section).
Hoover
Cleaning
Performance
This Hoover Cleaning Performance Sys-
tem is for comparing
the relative pro-
gressive performance
of Hoover
uprights only and not for comparison
with any other brands. The majority of
this rating is based upon the ASTM
International Carpet Cleaning
Effective-
ness Test (ASTM Test F608). Other per-
formance factors include Hose Power
(ASTM Test F558), Surface Litter Clean-
ing, Hard Floor Cleaning, Edge Clean-
ing, Cleaning Width, and Air Filtration.
If a minor problem occurs, it usually can
be solved quite easily when the cause is
found by using the check list below.
Possible cause
Possible solution
• Not firmly plugged in
• Plug unit in firmly
• No voltage in wall plug
• Check fuse or breaker
• Blown fuse or tripped breaker
• Replace fuse or reset breaker
• Thermal protector activated
• Allow cleaner to cool (this will reset the
thermal protector)
(see pg. 12).
• Brush roll shut-off tripped
• Turn cleaner OFF, clear brush rolls.
Turn cleaner back ON.
Possible cause
Possible solution
• Custom Control
TM
switch set on
BARE FLOOR position,
• Set switch to carpet position
• Agitators are obstructed.
• Clear obstruction
-
- .
-
Possible cause
Possible solution
• Thermal protector activated
• Allow cleaner to cool (this will reset the
thermal protector)
(see pg. 12).
• Agitator brush rolls worn
• Replace brush rolls
• Dirt cup full
• Empty dirt cup
• Incorrect carpet height setting
• Move nozzle control knob to lower
setting
• Blockage in air flow passage
• Clear blockage
• HEPA cartridge filter clogged
• Clean HEPA cartridge filter by either
tapping the side of the dirt cup or
removing the cartridge
filter as de-
scribed in the "Filter assembly"
section.
• Pre-filter clogged
• Clean pre-filter as described in
"Filter assembly" section.
• Dirt cup not properly installed
• Position dirt cup properly (Fig. 3-5).
• Dirt cup lid not positioned properly
or missing
• Ensure that dirt cup lid is properly
positioned.
• Filter assembly
not assembled
properly
• Ensure that filter assembly is
positioned
properly (Figs. 3-9 to 3-11).
"
se
"H
"_l"
I_
p
9
Possible cause
Possible solution
• Incorrect carpet height setting
• Move nozzle control knob to a
higher setting
Possible cause
Possible solution
• Blockage in hose
• Clear blockage.
Possible cause
Possible solution
• Filter assembly not installed
properly
• Remove filter assembly from dirt cup
and ensure that HEPA cartridge
filter is
properly attached to pre-filter screen
and that entire filter assembly is
properly repositioned
inside dirt cup.
(Figs. 3-6 through 3-11).
Note: Heavy debris may settle to the
bottom of the dirt cup and prevent the
dirt from spinning without affecting
cleaning performance.
The cleaner can
continue to be used even if the dirt is not
spinning inside the dirt cup.
However, if the dirt does stop spinning
AND there is a noticeable
decrease of
performance,
check the items under
"Cleaner won't pick up".
Possible cause
Possible solution
• Too much pressure being applied to
tool
• Continue using tool applying light
pressure.
• Blockage in turbine channel
• Remove blockage.
• Broken or worn belt
• Replace belt
• Low cleaner suction
• Check items under "Cleaner won't pick
up
".
11

Advertisement

Table of Contents
loading