Download Print this page

Advertisement

English
6.
Dipstick
insertion
and oil level check
Use a screwdriver
or similar tool to remove the plastic
cap on the lower part of the cylinder
(Fig. 3).
linder
Fig. 3
Insert the accessory
dipstick all the way to the bottom.
Remove the dipstick and make sure the oil level is
within
the range of the dipstick
notches (Fig. 4).
ipstick
[j
MAX.
_J_MIN.
Fig. 4
When the oil volume
is insufficient,
refer to the section
"Oil change-oil
topping
off" on page 11 for a descrip-
tion of howto
supply the oil.
,
Air coupler
installation
Screw in the air coupler to the joint (Refer to Fig. 1
and Fig. 5.). The screw size of the joint is 3/8". Use an
air coupler which
has the same screw size.
OPERATION
1.
Start up
Insert the plug into the receptacle and start the
compressor
by turning
the knob of the pressure
switch, to "AUTO".
(Refer to Fig. 1 and Fig. 5).
AkWARNING:
Do not stop or start the compressor
by use of the plug. Always use
"AUTO/OFF"
knob located on the
pressure switch.
The operation
of the compressor
is automatic
and is
controlled
by the pressure switch which stops it when
the pressure in the air-tank reaches the maximum
level and restart it when the air pressure drops during
use to the restart level.
The motor of the compressor
is fitted with a thermal
protection
inside-the wrap, which stops the
compressor
when the temperature
is too high. Should
this be tripped, the compressor
will restart automati-
cally after 15-20 minutes.
.
Adjustment
of working
pressure
Unlock the knob of the pressure reducer
pulling
it up,
adjust the pressure to the required
level by turning
the
knob clockwise
to increase and counterclockwise
to
decrease.
A pressure
gauge is provided
to know when the
required
pressure
is reached, lock the knob by
pushing it down firmly
(Fig. 5).
AkWARNING:
Check the manufacturer's
maximum
pressure rating for nailers, staplers
and accessories. Compressor outlet
pressure must be regulated so as to
never exceed the maximum
pressure
rating of the nailers, staplers and
accessories.
Knob
of the
Knob of the pressure reducer
pressure switch
/
__
Joint
Pressure gauge
.
Fig. 5
Shutdown
(1) Turn the knob of the pressure switch to "OFF". (Fig. 1)
(2) Unplug
the plug from power source.
(3) Open the drain cock located at the lower part of
the tank (Fig. 6).
Tank
Drain cock
Fig. 6
10

Advertisement

   Also See for Hitachi EC 10SC

This manual also for:

Ec 10sb

Comments to this Manuals

Symbols: 0