Table of Contents

Advertisement

Through-the-Wall
Installation
Instructions--Optional
The case may be installed
through
the wall
in both existing
and new construction.
Read completely,
then
follow
step-by-step.
[] IMPORTANT
Through-the-wall
installation
is not
appropriate
if any of the side louvers in the
case will be obstructed
by the wall.
All side louvers in the case must project on
the outdoor side of the wall.
The room side of the case must project into
the room at least 13A " from the finished wall.
The case must be installed level from side-
to-side and with a slight tilt from front to
rear. Use a level; about a 1/2 bubble will be
the correct case slant to the outside.
[]
Remove
the air conditioner
from the case.
For specific
instruction,
refer to the Window
Installation
Instructions.
[]
Make certain that a wall receptacle
is
available
close to the hole location
or make
arrangements
to install a receptacle.
[]
Place the case in the wall opening
and
secure with
12 1" long #10 wood
screws.
NOTE: Drill pilot holes, if necessary,
for
proper
installation.
If the frame
is oversized,
use shims to prevent
case distortion.
[] FINISH THE WALL OPENING
Caulk all four sides on the outdoor
side of
the case to prevent
moisture
from getting
through
to the interior
wall. Use of flashing
(drip rail) will further
prevent
water from
dripping
inside the wall and down
the
outside
of the building.
//
_ I-- Plaster line
Lintel angle (if required_
L
Trim molding
Caulk,ng
_P_J
II[
(if desired)
OUTSIDE
INSIDE
Air louvers
(must project on
the outdoor
side
of the wall)
/
Bottom
rail
Wood Filler and Caulking_
(above and below the flashing)
/
I(_/II/I._.
_
Flashing
(Drip rail)
T
4.5 cm (13/4") min.
15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ash18Asv24Asw24Asn24Asl24Asf24 ... Show all