Performance
Data Sheet
SmartWater Filtration System
GSWF Cartridge
This system has been tested according to NSF/ANSI 42/53 for reduction of the substances listed below.
The concentration of the indicated substances in water entering the system was reduced to a concentration
less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42/53.*
(100% safety factors built in for unmetered usage)
Standard
No. 42: Aesthetic
Effects
Parameter
Influent Challenge
Effluent
Chlorine
T&O
Particulate**
99.91%
Parameter
Turbidity
Cysts
Lead at pH 6.5
Lead at pH 8.5
Lindane
Atrazine
USEPA
MCL
USEPA
Influent
Average
1.845 mg/L
143,333 #/mL
Concentration
Average
2.0 mg/L÷10%
< 0.05 mg/L
at least 10,000 porticles/mL
29.83 #/mL
Standard No. 53: Health Effects
Maximum
0.05 rng/L
140 #/m L
Influent
Average
> 97.29%
99.98%
%Reduction
Minimum
96.43%
Influent Challenge
Effluent
% Reduction
MCL
1 NTU***
99.95% Reduction
0.015 mg/L
0.015 mg/L
0.0002 mg/L
0.003 mg/L
Average
10.3 NTU***
200,000 #/L
0.15 mg/L
0.14 mg/L
0.0216 mg/L
0.008 mg/L
Concentration
1+1 NTU***
Hinirnurn 50,000 L
0.15 mg/L+10%
0.15 mg/L÷10%
0.002 mg/L+10%
0.009 mg/L÷10%
Average
0.106 NTU
0
< 0.001 mg/L
0.001 mg/L
< 0.00002 mg/L
< 0.002 mg/L
Maximum
0.14 NTU
0
< 0.001 mg/L
0.003 mg/L
< 0.00002 mg/L
< 0.002 mg/L
Average
98.97%
> 99.99%
> 99.33%
> 99.29%
99.07%
> 76.12%
Minimum
98.61%
> 99.99%
> 99.33%
97.86%
98.75%
> 66.67%
Min. Required
Reduction
> 50%
>85%
Min. Required
Reduction
0.5 NTU
> 99.95%
0.010 mg/L
0.010 mg/L
0.0002 mg/L
0.003 mg/L
* Tested using a flow rate of 0.5 gpm; pressure of 60 psig; pH of 7.5 ± 0.5; temp. of 68 ° ++_ 5°F (20 ° ± 5°C)
** Measurement
in Partides/mL
Particles used were 0.5-1 microns
*** NTU=Nephelometric
Turbidity
units
Operating
Specifications
• Capacity: certified for up to 750 gallons (2,838 I);up to six months
• Pressure requirement: 40-120 psi (2.8-8.2 bar)
• Temperature: 33-100% (0.6-38°C)
• Flow rate: 0.5 gpm (1.9 Ipm)
General Installation/Operation/Maintenance
Requirements
• Flush new cartridge at full flow for 3 minutes to purge out trapped air.
• Replace cartridge when flow becomes too slow.
Special Notices
• Installation instructions, parts and service availability, and standard warranty are included with the product when shipped.
• This drinking water system must be maintained according to manufacturer's instructions, including replacement of filter
cartridges.
• Do not use with water that is microbiologicallg unsafe or of unknown quality without adequate disinfection before or after
the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts.
• The contaminants or other substances removed or reduced bg this water treatment system are not necessarily in gout water,
• Check for compliance with the state and local laws and regulations.
• Note that while the testing was performed under standard laboratorg conditions, actual performance may varg, Systems
must be installed and operated in accordance with manufacturer's recommended procedures and guidelines.
System tested and certified by NSF International against Standard 42 for the reduction of
chlorine, taste and odor, particulate Class I and Standard 53 for the reduction of cyst, lead,
Lindane, Atrazine and turbidity.
Manufactured for: General Electric Company, Louisville, KY40225