Installation instructions
CONNECTING
AN ELECTRIC DRYER (skip for gas dryers)
TOOLS AND MATERIALS
YOU
WiLL NEED FOR CONNECTING
THE ELECTRICAL
SUPPLY
[] Flat- or straight-blade
screwdriver
(may
be
needed
for cord strain
relief)
[]#2
Phillips-head
screwdriver
(for terminal
connections)
[] UL-listed
strain
relief
(may
be supplied
with
cord)
[] UL-listed
power
cord
- 3O-amp
- 240V
- #10 AWG
minimum
copper
conductor
- Closed-loop
or forked
terminals
with
upturned
ends
- 3-wire
(for construction
before
1996) or
4-wire
(for construction
after
1996)
FOR YOUR SAFETY:
WARNING
Before
making
the electrical
connection,
turn
off the circuit
breaker(s)
or remove
the
dryer's
circuit
fuse(s)
at the electrical
box.
Be sure the dryer
cord
is unplugged
from
the wall.
NEVER LEAVE THE ACCESS
COVER
OFF THE TERMINAL
BLOCK.
ELECTRICAL
CONNECTION
INFORMATION
FOR ELECTRIC
DRYERS
WARNING - Toreduce therisk
of fire, electrical
shock
and personal
injury:
,, Do not use an extension
cord
or an adapter
plug with
this appliance.
,, The dryer
must
be electrically
grounded
in accordance
with
local codes
and
ordinances,
or in the absence
of local
codes,
in accordance
with
the NATIONAL
ELECTRICAL
CODE, ANSI/NFPA
NO. 70.