4.
Q549.2E LA
4.2

Service Positions

For easy servicing of this set, there are a few possibilities
created:
The buffers from the packaging.
Foam bars (created for Service).
4.2.1

Foam Bars

Required for sets
1
42"
Figure 4-4 Foam bars
The foam bars (order code 3122 785 90580 for two pieces) can
be used for all types and sizes of Flat TVs.
See
Figure 4-4
for details. Sets with a display of 42" and larger,
require four foam bars [1]. Ensure that the foam bars are
always supporting the cabinet and never only the display.
Caution: Failure to follow these guidelines can seriously
damage the display!
By laying the TV face down on the (ESD protective) foam bars,
a stable situation is created to perform measurements and
alignments. By placing a mirror under the TV, you can monitor
the screen.
4.3

Assy/Panel Removal

4.3.1
Rear Cover
Warning: Disconnect the mains power cord before you remove
the rear cover.
Note: it is not necessary to remove the stand while removing
the rear cover.
Removing the Piezo Touch Control Panel PWB requires
special attention. Refer to
details.
1. Remove all screws of the rear cover.
2. Lift the rear cover from the TV. Make sure that wires and
flat coils are not damaged while lifting the rear cover from
the set.
4.3.2
Speakers
Each speaker unit is mounted with two screws. A sticker on the
the unit indicates if it is the right ("R") or left ("L") box, seen from
the front side of the set.
When defective, replace the whole unit.
2009-May-08
Mechanical Instructions
1
E_06532_018.eps
171106
Piezo Touch Control Panel
for
4.3.3

Ambi Light

Each Ambi Light unit is mounted on a subframe. Refer to
Figure 4-5
for details.
Figure 4-5 Ambi Light unit
1. Remove the Ambi Light cover [1].
2. Unplug the connector(s).
3. The PWB can now be taken from the subframe.
When defective, replace the whole unit.
Note: the screws that secure the AmbiLight units are longer
than the other screws.
4.3.4
Main Supply Panel
1. Unplug all connectors.
2. Remove the fixation screws.
3. Take the board out.
When defective, replace the whole unit.
4.3.5
IR & LED Board
Refer to
Figure 4-6
for details.
2
Figure 4-6 IR & LED Board
1
18310_212_090318.eps
090319
2
2