Performance Data Sheet - GE CFCP1NIYASS Owner's Manual And Installation Instructions

Bottom freezer models 21 and 25
Table of Contents

Advertisement

Available languages

Available languages

Performance
Data Sheet
SmartWater Filtration System
MWF Cartridge
This system
has been
tested
according
to NSF/ANSI
42/53
for reduction
of the substances
listed
below.
The concentration
of the indicated
substances
in water
entering
the system
was
reduced
to a concentration
less than or equal
to the permissible
limit for water
leaving
the system,
as specified
in NSF/ANSI
42/53.*
!00%
safety factors built in for unmetered
usage)
Standard No. 42: Aesthetic Effects
Parameter
USEPA
Influent
MCL
Challenge Concentration
Chlorine
-
2.0mg/L± 10%
T&O
-
-
Particulate**
-
_> 10,000particles/mL
Influent
Average
1,96 mg/L
6,400,000 #/mL
Effluent
Average
Maximum
0.06mg/L
0,11mg/L
58,833 #/mL
150,000 #/mL
% Reduction
Average
Minimum
96.77%
94.74%
99.14%
97.97%
Standard No. 53: Health Effects
Parameter
Effluent
Turbidity
Cysts
Asbestos
Leadat pH65
Leadat pH8.5
Mercuryat pH6.5
Mercuryat pH8.5
Alachlor
Lindane
2,4-D
Toxaphene
Benzene
Carbofuran
1,4dichlorobenzene
Atrazine
USEPA
MCL
0,5NTU
_> 99.95% Reduction
_> 99%Reduction
0,015mg/L
0,015mg/L
0.002mg/L
0.002mg/L
0.002mg/L
0.0002mg/L
0.070mg/L
0.003mg/L
0.005mg/L
0.040mg/L
0.075mg/L
0.003mg/L
Influent
Challenge Concentration
11+ 1 NTU***
Minimum50,000L
107 to 108 fibers/L; > 10pm
0.15mg/L+ 10%
0.15mg/L+ 10%
0.006mg/L+ 10%
0.006mg/L+ 10%
0.04mg/L+ 10%
0.002mg/L+ 10%
0.210mg/L+ 10%
0.015mg/L+ 10%
0.015mg/L+ 10%
0.080mg/L+ 10%
0.225mg/L+ 10%
0.009mg/L+ 10%
Influent
Average
105 NTU
118,750 #/L
57MF/L
0.1567mg/L
0.1433mg/L
0.0059mg/L
0.0057mg/L
0.0367mg/L
0.0020mg/L
0.2033mg/L
0.0160mg/L
0.0145mg/L
0.0830mg/L
0.2283mg/L
0.0087mg/L
Average
0.14NTU
< 1#/L
0.996MF/L
< 0.001mg/L
< 0.001mg/L
0.000350 mg/L
0.000325 mg/L
0.00023 mg/L
<0.00002 mg/L
0.00337 mg/L
0.00100 mg/L
0.000500 mg/L
0.001000 mg/L
0.000500 mg/L
< 0.0005mg/L
Maximum
028 NTU
4#/L
< 1 MF/L
< 0.001mg/L
< 0.001mg/L
0.0007mg/L
0.0006mg/L
0.0004mg/L
<0.00002 mg/L
0.011000 mg/L
0.001000 mg/L
0.000500 mg/L
0.001000 mg/L
0.000500 mg/L
< 0.0005mg/L
% Reduction
Average
Minimum
9854%
97.20%
> 99.99%
> 99.99%
99.60%
99.39%
99.36%
99.29%
99.30%
99.29%
94.70%
87.50%
93.20%
89.29%
99.34%
98.67%
99.00%
98.95%
98.32%
94.50%
93.44%
91.67%
9651%
95.83%
98.78%
98.65%
99.78%
99.77%
94.22%
93.33%
Tested using a flow rate of 0.50 gpm; pressure of 60 psig; pH of 7.5 +_0.5; temp. of 68 ° +_5°F (20° +_3°C)
** Measurement in Particles/ml. Particles used were 0.5-1 microns
*** NTU=Nephelometric Turbiditg units
Min. Required
Reduction
> 50%
_> 85%
Min. Required
Reduction
0.5NTU
_> 99.95%
_> 99%
0.010mg/L
0.010mg/L
0.002mg/L
0.002mg/L
0.002mg/L
0.0002mg/L
0.070mg/L
0,003mg/L
0.005mg/L
0.04mg/L
0.075mg/L
0.003mg/L
Operating
Specifications
[] Capacity:
certified for up to 500 gallons (1!55 I); up to six months
for models without
a replacement
filter indicator
light;
up to one gear for models
with a replacement
filter indicator
light
[] Pressure requirement:
40-120
psi (2.8-8.2 bar), non-shock
[] Temperature:
55-100°F
(0.6-58°C)
[] Flow rate: 0.5 gpm (1.9 Ipm)
General
Installation/Operation/Maintenance
Requirements
[] Flush new cartridge
at full flow for 5 minutes to purge out trapped
air.
[] Replace cartridge
when the indicator
light flashes or water flow rate is reduced on non-indicator
units.
Special
Notices
[] Installation
instructions,
parts
and service
availability,
and standard
warranty
are included
with the product
when
shipped.
[] This drinking water system must be maintained
according to manufacturer's
instructions, including replacement
of filter cartridges.
[] Do not use with water that is microbiologicallg
unsafe or of unknown
quality without
adequate
disinfection
before or after the
system. Systems certified for cyst reduction
may be used on disinfected
water that may contain filterable
cysts.
[]The
contaminants
or other substances
removed or reduced bg this water treatment
system are not necessarily
in your water.
[] Check for compliance
with the state and local laws and regulations.
[] Note that while the testing was performed
under standard
laboratory
conditions,
actual performance
may vary. Systems must
be installed
and operated
in accordance
with manufacturer's
recommended
procedures
and guidelines.
Standard No. 42: Aesthetic Effects
Chemical Unit
Chlorine Taste and Odor
Mechanical Filtration Unit
Particulate Reduction, Class I
System Tested and Certified by NSF International against ANSI/NSF Standard 42 & 53 for the reduction of:
Standard No. 53: Health Effects
Chemical Reduction Unit
Alachlor and Atrazine Reduction
Benzene and Carbofuran Reduction
1,4 dichlorobenzene and 2,4-D Reduction
Lead and Lindane Reduction
Mercury and Toxaphene Reduction
Mechanical Filtration Unit
Turbidity Reduction
Cyst and Asbestos Reduction
Manufactured for: General Electric Company, Louisville, KY40225
EPA EST.No. 070595-MN-001
43

Advertisement

Chapters

Table of Contents
loading

Table of Contents