Using The Electronic Indicator System - Craftsman 113.247440 Owner's Manual

12-inch electronic band saw
Table of Contents

Advertisement

USING
THE
ELECTRONIC
INDICATOR
SYSTEM
1 Setting the Bevel Angle Reference
Point
Whenever
the battery
is installed or a new zero
point is desired,
it is necessary
to set the zero
reference
Normally
the zero reference is set with
the blade vertical to the table
When the blade is
in the desired position
for the zero point do the
following
a Press the
_
key if display is off
b Press the _
key, then the _
key,
c. Display should read: _'_
£'1
ri}
U. UJ
2. Selecting
Blade Tension
a Press the _
key if display is off
b Press the _
key
c The digital
display
will show one of seven
tension settings
Turn the tension knob until
the correct
read-out
appears for the blade or
sanding
belt you have selected
Read-out
_a-tescorrect
tension for:
L
Loose - no tension
S
Sanding
Belt
.125
1/8" blade
.250
1/4" blade
.375
3/8" blade
.500
1/2" blade
E
Overtensioned
3 Blade Speed
The
digital
display
wilt read out one of two
starting
speeds, depending
on where the motor
belt is positioned
on the pulleys
The two starting
speeds are 3000 FPM and 1500 FPM The speed
ranges for each starting
point are:
3000
1500
2800
1400
*2600
"1300
2400
1200
2200
1100
2000
I000
The band saw motor will stall if the blade speed
drops two steps* below operating
speed
NOTE:
It is important
to maintain
maximum
cutting efficiency
by keeping the blade speed as
fast as possible
Do not feed the work piece too
rapidly
It will overload
the motor and stall the
blade
18

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents