HOW TO OPERATE YOUR HAND VACUUM
Plug into 120V outlet.
1. Hold the hand vacuum firmly with your hand on the Handle (4).
2. Push the On/Off Power Switch (2) to "On" position.
3. Start vacuuming.
CAUTION:
The Hand Vacuum is a very powerful unit. Make sure that
you hold it firmly, otherwise it can slip out of your hand
and cause injury.
USING THE UNIT WITH FLOOR-TO-CARPET ATTACHMENT
1. Slide the narrow end of one of the extension tubes (14) into the wide end of the
other extension tube.
2. Slide the narrow end of the long extension tube inside the Floor-to-Carpet
attachment (15).
3. Slide the wide end of the assembled extension tube (14) into the round end of the
Curved Hose / Wand Extension (16).
4. Slide the narrow, oval side of the Curved Hose/Wand Extension (16) into the
suction hole (3) of the vacuum unit.
5. Attach the shoulder strap (5) to the vacuum unit and hang it from your shoulder.
6. You can now proceed to vacuum your carpet or hard floor.
Please Note:
To vacuum wooden floors, press Floor-to-Carpet Lever (15A) down, to lower the bristles
down.
To vacuum carpets, press Floor-to-Carpet Lever (15A) up, to raise the bristles up. Very flat
carpets can sometimes be vacuumed with the bristles down.
Please Note: If floor nozzle does not move easily, we suggest that you reduce
suction power on the variable suction control (16A).
Please Note:
The Variable Suction Control (16A) will allow you to adjust the amount of suction by sliding it
up or down.
Note: Variable length can be obtained by using one, or both of the extension tubes.
4
USING THE CONVERTIBLE BRUSH & BRISTLE BRUSH (12 & 13)
In order to vacuum high, hard to reach places such as ceilings, curtains/drapes, etc., use
the Convertible Brush and Bristle Brush (12 & 13) as follows:
1. Remove the Floor - to - Carpet attachment (15).
2. Insert the Convertible Brush (12).
3. If you need a brush action, slide on the Bristle Brush (13) onto the
Convertible Brush (12).
4. When vacuuming drapes/curtains, we recommend adjusting the variable suction
control (16A).
CHANGING & CLEANING THE DUST CUP FILTER
Warning: Always unplug from electrical outlet before opening the Dust Cup
(container) (10).
1. To open the Dust Cup (container) (10), push button (1) and pull out the Dust Cup
(container ) (10), (fig. 1).
2. Pull out the Dust Cup Filter (8), (fig. 2).
3. Empty the dust from the Dust Cup Filter (8).
4. Rinse the Dust Cup Filter (8) in cold water, and then wait until it dries completely
before replacing it into the Dust Cup (container) (10).
5. Place the Dust Cup Filter (8) carefully into the Dust Cup (container) (10).
6. Attach the Dust Cup (container) (10) to the Hand Vacuum.
Fig. 1
CAUTION:
The suction hole (3) must be open, free of any obstructions at
all times. Otherwise, the motor will overheat and could
become damaged.