Craftsman 113.201170 Owner's Manual page 12

300 amp high frequency arc stabilizer attachment
Table of Contents

Advertisement

STAINLESS
STEEL
AC-HF
DC-SP
TUNGSTEN
WELDING
WELDING
SHIELDING
FILLER
ME3`AL
TYPE OF
ELECTRODE
CURRENT
CURRENT
GAS-ARGON
ROD
THICKNESS
WELD JOINT
DIAMETER
(AMPS)
(AMPS)
CU, FT,/HR.
DIAMETER
3/64
(_046-)
Square
Groove
t/16"
(.052")
65-100
50-80
10
1/16 '_ (.062"')
3/64" (,046)
Fillet
1/16" (.062")
65-100
50-80
10
1/16" (.062")
1/t6"
(.062")
Square
Groove
1/16'" (,062-)
80-130
65-t05
t2
t/16"
(.062")
1/16" (.062")
Fillet
t/16"
(,062")
95-t55
75-125
t2
t/16"
(,062")
3/32" (.093")
Square
Groove
1/16" (.062")
t05-155
85-125
12
3/32" (.093-)
3/32" (,093')
Fitlet
1/t6"
(,062")
120-170
95-135
12
3/32" (,093")
1/8" (,t25")
Square Groove
1/16" (.062)
125-170
t00-135
12
3/32 _ (,093")
118" (.125")
Fillet
1/16" (.062")
145-180
t 15-145
12
3/32" (.093")
3/16" (. 187-)
Square Groove
3/32" (.093")
t 90-200
t 50-200
15
1/8'* (. t 25"}
MAGNESIUM
ALLOYS
AC-HF
DC-SP
3`'UNGSTEN
WELDING
WELDING
SHIELDING
FfLLER
METAL
TYPE OF
ELECTRODE
CURRENT
CURRENT
GAS-ARGON
ROD
THICKNESS
WELD JOIN3"
DIAMETER
(AMPS)
(AMPS)
CU, FT./HR.
DIAMETER
1/32" (,031')
Square
Groove
1/16'" (,062")
25-40
--
t5
3/32" (,093")
t/32"'
(.03t _)
Fillet
1!t6"
(,062-)
30-45
--
15
3/32" (,093")
1/16"' (.062 _)
Square Groove
t/16 _' (°062")
45-60
--
15
3/32'
(.093")
1/16" (,062")
Fillet
1/t6"
(.062")
45-60
--
15
3/32" (,093")
3/32 _ (.094)
Square Groove
1/16" (.062")
70-90
--
t5
3/32" (.093"}
3/32" (,094)
Fillet
!/16
(.062")
70-90
--
t5
3/32" (.093")
1/8" (.125")
Square Groove
3/32" (,093")
95-1 t5
--
25
1/8" (.125")
t/8"
(.125")
Fillet
3/32" (,093")
95-1t5
_
25
1/8
(,125")
3/16" (.187'")
Vee Groove
1/8" (,!25")
95-115
--
25
t/8'" (.125")
3/t6"
(,187")
Fitter
1/8 "_(.125")
95_1t5
--
25
1/8" (. t25")
1/5- (,250)
Vee Groove
1/8 _ (,125")
1 t0-130
_
25
3/16'
(,t8T)
1/4" (.250")
Fillet
1/8" (,t25")
110-!30
--
25
3/t6"
(.187 '_)
3/8" (,375-)
Vee Groove
t/8'
(.125")
135-165
--
30
3/16'
(.187")
3/8" (.375")
Fillet
t/8
(,125)
!35-165
--
30
3/16" (, 187")
AC-HF
(ALTERNATING
CURRENT-HIGH
FREQUENCY
STABILIZATION)
DC-SP (DlRECT
CURRENT-STRAiGHT
POLARITY)
Using the High Frequency Arc Stabilizer
t.. Set the welder to the current
recommended
for
the work being done, then turn "On" the welder
and Arc Stabilizer
switches.
2. Turn on the gas and set the flowmeter
to the
recomntended
gas flow
3. Lower the torch toward the work slowly until the
arc is established.
CAUTION." Do not touch the work with the tungsten
electrode_
4. When the arc is established
the torch should be
held so the tungsten tip is positioned at an angle
of approximately
75 degrees to the surface
of
the work.
12