   Related Manuals for KitchenAid 50

   Summary of Contents for KitchenAid 50

  • Page 1

    ICE MAKER Model 50 -_I, ., . ; / i,&.rT+.~-:- * .“:*, -A:‘,:. ~“~~$i+&~~,~-~~~~ ‘..*...;?& \*l?~.<.‘. ,.. _ -.:T.$z.*: .>a : k ~;P-f&-.;‘~.-&p&+~~.~ :~ ;- ~,, _, .‘ ;G.,;;,. ::? : ,:i i’. * ‘Al *;, &!g ;‘p$c**,; :; :, ”...

  • Page 2

    Changing the bin door Thermostat calibrations panel If ice maker is installed above two thousand feet of altitude, the bin and evaporator thermostats must be adjusted to a warmer setting. Disconnect electricity, The storage bin door is designed to accept an optional remove thermostat and follow the directions for turn-...

  • Page 3

    ,.>, ._;,- . . - . . - . ; 2. Area should be well ventilated with temperature 4. Remove all tape and packaging material from the above 55OF and below 11 OOF. Best results are ob- outside and inside of the cabinet. See Figure 4. tained between 7O’JF and 9OOF.

  • Page 4

    FIGURE 5 RIGHT END VIEW BACK VIEW -17.7/w*- WATER INLET SOLENOID VALVE 4” LONG 5/8” I.D. RUBBER 34-13132 DRAIN TUBE - RUN TO 7.112” HOLE FOR FIELD -Lt- SUPPIED WATER BEND FIELD SUPPLIED WATER LINE TO CONNECT TO WATER VALVE FITTING l-1/2”...

  • Page 5

    For the Alternate grounding method electrician DO NOT, UNDER ANY CIRCUMSTANCES, REMOVE THE POWER SUPPLY CORD GROUND PRONG. Electrical requirements If changing and properly grounding the wall receptacle A 115 Volt, 60 Hz, AC only, 15 Amp fused electrical is impossible and where local codes permit (consult supply is required (time delay fuse or circuit breaker your electrical inspector), a temporary adapter may be...

  • Page 6

    How it works As the room and water temperatures vary, so will the amount of ice produced. This means that higher . Compressor runs operating temperatures will result in reduced ice production. 9 Condenser fan runs The unit will shut off when ice in the storage bin Water pump runs (circulates water) touches the bin thermostat well and will automatical-...

  • Page 7

    Unit wiring diagram CUBELET CUTTER GRIDS This model operates at 115 volts except for the cutter grid circuit which operates at 8.5 volts at 1 amp. The compressor runs at all times except when the bin thermostat becomes satisfied and opens up. This de- energizes the system except for the transformer cutter grid.

  • Page 8

    HOME .% APPLIANCES Making your world a little easier. In the event your WHIRLPOOL appliance should need service, call dealer from whom purchased @ service company. is in the Yellow Pages of your appliance or a WHIRLPOOL franchised TECH-CARE telephone directory listed under...