Message ID
KAPL13508-E
KAPL13509-E
KAPL13510-E
KAPL13511-E
KAPL13512-E
KAPL13513-E
8-124
Message Text
You lack permission for
executing the utility for update
system scripts.
The utility for update system
scripts can be executed with the
name dlmupdatesysinit only.
Multiple instances of the utility
for update system scripts cannot
be executed concurrently.
The version of the kernel
supported by the installed HDLM
does not match the currently
running kernel version.
The user stopped the utility for
update system scripts.
An invalid parameter was
specified. Parameter = aa...aa
Messages
Hitachi Dynamic Link Manager User Guide (for Linux(R))
Explanation
was output just before this
message.
Details
The current user does not have
authority to execute
dlmupdatesysinit utility.
Action
Re-execute dlmupdatesysinit
utility as a user with root
permission. Refer to
dlmupdatesysinit Utility for
Updating System Scripts on page
7-39.
Action
Change the utility name back to
dlmupdatesysinit, and then
execute it. Refer to
dlmupdatesysinit Utility for
Updating System Scripts on page
7-39.
Action
Check the execution result of the
executing dlmupdatesysinit
utility. Re-execute the
dlmupdatesysinit utility if
necessary. Refer to
dlmupdatesysinit Utility for
Updating System Scripts on page
7-39.
Details
The version of the kernel to which
installed HDLM has adjusted and
the kernel that is running now is
not corresponding. There is a
possibility of installing the
package of the kernel after
installing HDLM.
Action
Install HDLM that adjusts to the
kernel that is running now.
Action
Re-execute the dlmupdatesysinit
utility if necessary. Refer to
dlmupdatesysinit Utility for
Updating System Scripts on page
7-39.
Details
aa...aa: Specified parameter
Action