Change Battery - Kenmore 625.385560 UltraFilter 650 Owner's Manual

Reverse osmosis system
Hide thumbs Also See for 625.385560 UltraFilter 650:
Table of Contents

Advertisement

CHANGE COLLET AND O-RING
1. Remove the collet and o-ring
from the fitting
with a
small screwdriver.
Be careful
not to scratch the internal
walls of the collet port. See Figures 27 & 28.
2. Clean collet
port, lubricate
and insert the o-ring
seal
into the bottom
of the port. See Figures 27 & 28.
3. Push the collet inward
until it locks in place. See Figures
27 & 28.
Push o-ring
seal into
bottom
of
port
then
follow
with
collet.
_/_}\
1
Fitting
Cotlet
Change collet and o-ring
Figure 27
Collet (depress to
remove tubing)
Disconnect Tubing
Figure 28
CHANGE BATTERY
When the coin battery
is first applied
at initial
start up,
the LED indicator
light will flash in a red, amber, green
sequence. All timers and counters are reset to zero. In
order to reset the time and gallon
count feature,
push the
the button
on the PWA and hold until the LED flashes and
release.
The battery
needs to be replaced
at the time of
filter
replacement.
Use only lithium
batteries
(CR 2032 or
equivalent).
Improper
placement
of battery
could dam-
age electronics.
Use care when inserting
the battery
to
align it correctly
on PWA with the proper
polarity.
PWA
board
Battery
J
Reset button
Figure 29
NOTE: It is not recommended
that the RO assembly
be
opened.
If this becomes
necessary, pay careful
attention
to the layout
of the parts and the routing
of the tubing.
It
will be necessary
to assemble
the unit exactly
as shown
for the system to fit together
and function
properly.
Figure 30
Questions?
Call The Kenmore
Water
Line 1-800-426-9345
or visit KenmoreWater.com
21

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Elite 625.385560Elite ultrafilter 650