G Entering (Dialing) A Fax Number With A; Entering (Dialing) A Fax Number With A Sub-Address And Passcode; Creating A Memory Box For F-Code Transmission - Sharp AR-FX10 Operation Manual

Facsimile expansion kit for ar-c262m
Table of Contents

Advertisement

ENTERING (DIALING) A FAX NUMBER WITH A SUB-
ADDRESS AND PASSCODE
When transmitting to a memory box in another fax machine, the sub-address and passcode must be entered after
the other machine's fax number. Enter the other machine's fax number as explained for a normal transmission (page
2-2) or for a polling operation (see "USING THE POLLING FUNCTION" on page 3-6), and then enter the sub-address
and passcode as follows:
1
Dial the fax number of the other machine,
or touch a one-touch key.
SPE
CORPO.TPS
SHARP GROUP
If the sub-address and passcode have been
programmed into the one-touch key, the following
steps are not needed.
2
Touch the [SUB ADDRESS] key.
CONDITION
SETTINGS
SUB ADDRESS
ADDRESS REVIEW
NOTES
G You can program a sub-address and passcode into a one-touch key along with the fax number (refer to page 6-
3 to 6-4).
G Manual transmission (on-hook dialing) using a sub-address and passcode is not possible.

CREATING A MEMORY BOX FOR F-CODE TRANSMISSION

Operations that use F-Code memory boxes include F-Code polling memory (following page), F-Code confidential
transmission (page 4-6), and F-Code relay broadcast transmission (page 4-8). To perform these operations, a
memory box for each type of transmission must be created.
Memory boxes are created in the custom settings. Up to 100 boxes can be created.
The information programmed in each memory box varies slightly depending on the type of
operation. Refer to pages 6-10 to 6-14 for the procedures for creating, editing, and deleting
memory boxes.
After you have programmed a memory box, inform the other party of the box's sub-address and passcode.
NOTE
If you attempt to create a box when 100 boxes have already been created, a message will appear and you will not
be able to create the box. First delete an unused box (See "EDITING AND DELETING A MEMORY BOX" on page
6-14.), and then create the new box.
TRANSMISSION BETWEEN MACHINES SUPPORTING F-CODES
If the condition settings
screen appears, touch
the
[ADDRESS
DIRECTORY]
key
to
display
the
address
directory screen (refer to
page 1-4).
When
the
[SUB
ADDRESS]
key
is
touched,
a
slash
"/"
appears at the end of the
fax number. If you make
a mistake, press the [C]
key to clear the mistake.
3
Use the numeric keys to enter the sub-
address of the other machine's memory
box (max. 20 digits)
Touch the [SUB ADDRESS] key once
4
again.
A slash "/" appears at the end of the sub-address.
5
Use the numeric keys to enter the
passcode of the other machine's memory
box (max. 20 digits)
If a passcode has not been established for the
other box, this step is not necessary.
If you make a mistake,
press the [C] key and re-
enter the correct digit(s).
4-3
4

Advertisement

Table of Contents
loading

Table of Contents