Sharp AH-A07CR Operation Manual

Split type room air conditioner

Advertisement

• Uses ozone layer friendly refrigerant R-410A.
• Verwendet das die Ozonschicht schonende
Kühlmittel R-410A.
• Utilise un réfrigérant qui n'attaque pas la couche
d'ozone, le R-410A.
• Utiliza refrigerante R-410A que no daña la capa de
ozono.
• Utilizza il refrigerante R –410A che non danneggia
il buco nell'ozono.
• Usa refrigerante R-410A amigo da camada de
ozono.
• ρησιµ π ιεί ψυκτικ R-410A α λα ές για τ
στρώµα τ υ
ντ ς.
• Gebruikt de ozon-vriendelijke koelvloeistof R-410A.
INDOOR UNIT
ZIMMERGERÄT
UNIT INTERIEURE
UNIDAD INTERIOR
UNITA' INTERNA
UNIDADE INTERIOR
ΕΣΩΤΕΡΙΚΗ ΣΥΣΚΕΥΗ
BINNEN-UNIT
AY-A07CR
AY-A09CR
AY-A12CR
AH-A07CR
AH-A09CR
AH-A12CR
R
OUTDOOR UNIT
AUSSENGERÄT
UNIT EXTERIEURE
UNIDAD EXTERIOR
UNITA' ESTERNA
UNIDADE EXTERIOR
Ε ΩΤΕΡΙΚΗ ΣΥΣΚΕΥΗ
BUITEN-UNIT
AE -A07CR
AE -A09CR
AE -A12CR
AU-A07CR
AU-A09CR
AU-A12CR
AY -A07CR
AY -A09CR
AY -A12CR
AH -A07CR
AH -A09CR
AH -A12CR
SPLIT TYPE
ROOM AIR CONDITIONER
ZWEITEILIGES
KLIMAGERÄT
CLIMATISEUR INDIVIDUEL
EN DEUX PARTIES
ACONDICIONADOR DE AIRE
DE DOBLE SERVICIO
CONDIZIONATORE D'ARIA
DA CAMERA TIPO SPLIT
AR CONDICIONADO
DE DUAS UNIDADES
ΑΙΡΚ ΝΤΙΣΙ Ν ∆ΩΜΑΤΙ Υ
ΤΥΠ Υ SPLIT
КОМНАТНЫЙ КОНДИЦИОНЕР
ДВУБЛОЧНОГО ТИПА
OPERATION MANUAL
BEDIENUNGSANLEITUNG
NOTICE D'UTILISATION
MANUAL DE INSTRUCCIONES
MANUALE DI ISTRUZIONE
MANUAL DE INSTRUÇÕES
ΕΓ ΕΙΡΙ∆Ι
ΛΕΙΤ ΥΡΓΙΑΣ
GEBRUIKSAANWIJZING

Advertisement

Table of Contents
loading

Summary of Contents for Sharp AH-A07CR

  • Page 1 AY -A07CR AY -A09CR AY -A12CR AH -A07CR AH -A09CR AH -A12CR SPLIT TYPE ROOM AIR CONDITIONER ZWEITEILIGES KLIMAGERÄT CLIMATISEUR INDIVIDUEL • Uses ozone layer friendly refrigerant R-410A. • Verwendet das die Ozonschicht schonende EN DEUX PARTIES Kühlmittel R-410A. • Utilise un réfrigérant qui n’attaque pas la couche ACONDICIONADOR DE AIRE d’ozone, le R-410A.
  • Page 3: Table Of Contents

    ENGLISH Thank you for purchasing a SHARP air conditioner. Please read this manual carefully before operating the product. CONTENTS • ONE-HOUR OFF TIMER ....E-11 • PRECAUTIONS ........... E-1 • TIMER OPERATION ......E-12 • ADDITIONAL NOTES ON OPERATION ..E-3 •...
  • Page 4: Precautions

    PRECAUTIONS CAUTIONS FOR USE Open a window or door periodically to ventilate the room, especially when using gas appliances. Insufficient ventilation may cause oxygen shortage. Do not operate the buttons with wet hand. It may cause electric shock. For safety, turn the circuit breaker off when not using the unit for an extended period of time.
  • Page 5: Additional Notes On Operation

    ADDITIONAL NOTES ON OPERATION OPERATING TEMPERATURE RANGE • The built-in protective INDOOR TEMP. OUTDOOR TEMP. device may prevent the 32˚C D.B. 43˚C D.B. unit from operating when upper limit 23˚C W.B. used out of this range. COOLING 21˚C D.B. 21˚C D.B. lower limit •...
  • Page 6: Part Names

    PART NAMES INDOOR UNIT 1 Inlet (Air) 2 Open Panel 3 Air Filters 4 AUX. Button 5 RECEIVER Window 6 Power Supply Cord 7 Indicator Panel 8 Vertical Adjustment Louvres 9 Horizontal Adjustment Louvres 0 Outlet (Air) q Remote Control w AUTO FAN SPEED Lamp (green e FAN SPEED Lamp (green r TIMER Lamp (orange...
  • Page 7: Remote Control

    REMOTE CONTROL 1 TRANSMITTER 2 DISPLAY (Liquid Crystal Display) 3 ON/OFF Button MODE TEMP. 4 THERMO. (Thermostat) Button 5 DISPLAY Button TIMER 6 MODE Button TEMP. 7 TIMER ON Button (for setting the timer) 8 ONE-HOUR OFF TIMER Button DISPLAY MODE 9 TIMER OFF Button (for setting the timer) 0 FAN Button q TIMER CANCEL Button...
  • Page 8: Using The Remote Control

    USING THE REMOTE CONTROL LOADING BATTERIES Use two size-AAA (R03) batteries. Remove the battery cover at the back of the remote control. Insert batteries in the compart- ment, making sure the ± and — polarities are correctly aligned. • Lines will be indicated on the display when batteries are properly installed.
  • Page 9 CAUTION • Do not allow the signal receiver window to receive strong direct sunlight, since it can adversely affect its operation. If the signal receiver window is exposed to direct sunlight, close a curtain to block the light. • Using a fluorescent lamp with a quick starter in the same room may interfere with transmission of the signal.
  • Page 10: Basic Operation

    BASIC OPERATION Press the MODE button to select the operation mode. AUTO HEAT COOL HEAT is only for AY-A07CR/AY-A09CR/AY-A12CR) MODE TEMP. Press the ON/OFF button to start op- eration. • The red OPERATION lamp ( ) on the TIMER unit will light. TEMP.
  • Page 11 TIPS ABOUT AUTO MODE In the AUTO mode, the temperature setting and mode are automatically selected according to the room temperature when the unit is turned on. Modes and Temperature Settings for Models AH-A07CR/AH-A09CR/AH-A12CR Automatic Operation Room temp. at opera- tion start-up Mode Thermostat Setting...
  • Page 12: Adjusting The Air Flow Direction

    ADJUSTING THE AIR FLOW DIRECTION VERTICAL AIR FLOW DIRECTION The air flow direction is automatically preset in each mode as follows for optimum comfort: COOL and DRY mode Horizontal air flow HEAT mode Diagonal air flow (only for AY-A07CR/AY-A09CR/AY-A12CR) HOW TO ADJUST THE AIR FLOW DIRECTION Adjustment range Press the SWING button on the remote control once.
  • Page 13: One-Hour Off Timer

    ONE-HOUR OFF TIMER When the ONE-HOUR OFF TIMER is set, the unit will stop operating after one hour. Press the ONE-HOUR OFF TIMER button. • The remote control displays “ ”. • The orange TIMER lamp ( ) on the unit will light MODE TEMP.
  • Page 14: Timer Operation

    TIMER OPERATION TIMER OFF The unit will turn off automatically according to your setting. Timer duration can be set from minimum 0.5 hours (30 minutes) to maximum 12 hours. Up to 9.5 hours, you can set by 0.5 hours (30 minutes) increments and from 10 to 12 hours, by 1 hour increment.
  • Page 15: Timer On

    TIMER ON The unit will turn on automatically according to your setting. Timer duration can be set from minimum 0.5 hours (30 minutes) to maximum 12 hours. Up to 9.5 hours, you can set by 0.5 hours (30 minutes) increments and from 10 to 12 hours, by 1 hour increment.
  • Page 16: Auxiliary Mode

    AUXILIARY MODE Use this mode when the remote control is not available. TO TURN ON Lift the front panel of the indoor unit and press the AUX. button on the operation panel. • The red OPERATION lamp ( ) on the unit will light and the unit will start operating in the AUTO mode.
  • Page 17: Maintenance

    MAINTENANCE CAUTION Be sure to disconnect the power cord from the wall outlet or turn off the circuit breaker before performing any maintenance. CLEANING THE FILTERS The air filters should be cleaned every two weeks. TURN OFF THE UNIT REMOVE THE FILTERS 1 Lift the open panel.
  • Page 18: Before Calling For Service

    BEFORE CALLING FOR SERVICE The following conditions do not denote equipment malfunctions UNIT DOES NOT OPERATE SWISHING NOISE The unit will not operate if it is turned on The soft, swishing noise is the sound of immediately after it is turned off. The unit will not the refrigerant flowing inside the unit.
  • Page 20 SHARP CORPORATION OSAKA, JAPAN Printed in Thailand TINSEA335JBRZ TH 02FO 1...