Faculty Tests - Canon MultiPASS C755 Service Manual

Service manual
Hide thumbs Also See for MultiPASS C755:
Table of Contents

Advertisement

7.2.7 Faculty tests

The faculty tests are selected by pressing the 6 button from the test mode menu. These tests test the
following faculties of this fax.
Test type
Sensor tests
Operation panel test
Line signal reception test
a) Sensor tests
The sensor test is selected by pressing the 3 button from the faculty test menu. In this test, you can
check the status of each sensor of this fax in item 1 on the display.
You can also check if sensors that use actuators and microswitches are operating correctly by moving
the actuator or microswitch. (See page 3-33 Faulty scanner unit's sensors.)
The sensor tests cannot be used to test all of the sensors. The following sensors cannot be
tested with the sensor tests:
NOTE
Home position sensor, pickup roller sensor, cover sensor, and ink detection
sensor.
If any of these sensor are faulty, an error message or service error code will appear to
indicate the faulty sensor.
MultiPASS C755 Chapter 3: Maintenance & Service
Overview
Test whether the sensors are operating correctly.
Tests whether the button switches on the control panel are
operating correctly.
Tests whether the NCU board signal sensor and frequency
counter are operating correctly.
3-67

Advertisement