Download Print this page

Holding The Blower - Craftsman INCREDI.PULL 316.794831 Operator's Manual

4-cycle handheld blower
Hide thumbs Also See for INCREDI.PULL 316.794831:

Advertisement

Available languages

Available languages

HOLDING
THE BLOWER
Before operating the unit, stand in the
operating position and check for the
following:
The unit in the right hand and on the
right side of the body. Do not block
the air intake which will affect the
unit's performance
(Fig. 11).
If the conditions
are dusty, the
operator is wearing a dust mask or
face mask
The unit is in good working condition
The tubes are in place and secure
OPERATING TIPS
' i
Fig. 11
Using the Variable Speed Cruise Control
For longer periods of operation and to
cruise
eliminate possible finger fatique.
1.
Move the variable speed cruise
control toward the FAST position to
incrementally
increase or maintain
the unit's engine speed (Fig. 12).
When the variable speed cruise
control is pressed, the trigger will
recede into the handle.
2. To decrease engine speed, move the
Fig.12
variable speed cruise control to the
SLOW position and the trigger will return to idle (Fig. 12).
Other Tips
Always use a firm grip when holding the unit.
To reduce the risk of hearing loss, hearing protection is required.
Operate power equipment only at reasonable
hours when people might
not be disturbed.
Comply with times listed in local ordinances.
Usual
recommendations
are 9:00 am to 5:00 pm, Monday through Saturday.
To reduce noise levels, operate the unit at the lowest possible speed to
do the job.
Use rakes and brooms to loosen debris before blowing.
Watch for bystanders,
open windows or cars; blow debris safely away.
Use the curved tube extension so the unit can work closer to the ground.
Clean up after using blowers and other equipment.
Dispose of debris
appropriately.
MAINTENANCE
SCHEDULE
Perform these required maintenance
procedures
at the frequency stated in
the table. These procedures should also be a part of any seasonal tune-up.
NOTE:
Some maintenance
procedures
may require special tools or skills
such as replacement
or repair of the emission control devices
and system. If unsure about these procedures or tools are not
available; take the unit to Sears or other qualified service dealer.
Call 1=800-4=MY-HOME®
for more information.
FREQUENCY
MAINTENANCE
REQUIRED
SEE
Every 10 hours
Clean air filter
p. 7
First 10 hours
Change oil
p. 6
Check rocker arm to valve clearance and adjust
p. 7
Check spark plug condition and gap
p. 7
Every 40 hours
Change oil
p. 6
Check rocker arm to valve clearance and adjust
p. 7
Check spark plug condition and gap
p. 7
CHECKING
THE OiL LEVEL
The importance
of checking
and
maintaining the proper oil level in the
crankcase cannot be overemphasized.
Check oil before each use:
1. Stop the engine and allow oil to drain
.....................................
_
Oil
Fill Line-_
....
into the crankcase.
2.
Place the engine on a level surface.
3.
Clean the area around the oil plug
before removing it. Keep dirt, grass
Fig.13
clippings, and other debris out of the
engine,
eil Plug
4.
Remove the oil plug (Fig. 14).
O-Ring
--
5.
Look into the oil fill hole (use a
flashlight if needed). The oil should
be just touching the innermost
thread (Fig. 13).
eil Fill Hole
6.
If the oil level is not touching the
innermost thread on the oil fill hole,
add a small amount of oil to the oil
fill hole and recheck (Fig. 13). Repeat
this procedure until the oil level
reaches the innermost thread on the
oil fill hole.
NOTE:
Do not overfill the unit.
NOTE:
Make sure the O-ring is in
place on the oil plug when
checking
and changing the oil
(Fig. 14).
CHANGING
THE OIL
Change the oil while the engine is still
warm. The oil will flow freely and carry
away more impurities.
1. Remove the oil fill plug.
2.
Pour the oil out of the oil fill hole and
into a container by tipping the unit
to a vertical position (Fig. 15). Allow
ample time for complete
drainage.
Fi, Level
3.
Wipe up any oil residue on the
unit and clean up any oil that may
have spilled. Dispose of the oil
according to Federal, State and local
regulations.
4.
Refill the crankcase with 2.03 fluid
ounce (60 ml) of SAE 30 SF, SG, SH
oil (Fig. 17).
NOTE:
Use the bottle and spout
saved from initial use to
measure the correct amount of
oil. The fill line on the bottle's
label measures approximately
2.03 ounces (60 ml) (Fig. 16).
5.
Check the level, See Checking the
Oil Level.
6.
Once full, replace the oil plug.
Fig. 14
Fig. 15
Fig. 16