Error information

Error messages
Set up the parameter.
It has not been registered to PJ as a
group.
Cannot be displayed as PJ is under
display.
Cannot connect to PJ.
Cannot transfer data to PJ.
Cannot receive data from PJ.
Other PC has authority.
Cannot complete "Network
Communication".
Other PC has authority. Cannot
obtain authority.
Invalid port number
PJ has not started Network
Communication. Close the window
and open it again.
Cause and corresponding
Error when the communication is executed. The parameter setting (host
name, capture port) has not been set.
➔ Check parameter setting (+p.90)
Error when Start Communication or Start real time capture is executed. The
IP address of the computer has not been registered.
➔ Register the IP address by using the web browser (+p.97)
Error when Start Communication or Start real time capture is executed. The
other capture, viewer or memory viewer function is now operating.
➔ Wait until the communication function is available.
Cannot establish the connection with the projector when the Start
communication is executed, Terminate Communication, Capture transfer,
Start real time capture or Terminate capture.
➔ Check connection of the network cable.
Cannot transfer the data to the projector when the Start Communication,
Terminate Communication, Capture transfer, Start real time capture or
Terminate capture is executed. The time-out period is 10 seconds.
➔ Check the connection of the network cable.
Cannot receive the data from the projector when the Start
Communication, Terminate Communication, Capture transfer, Start real
time capture or Terminate capture is executed. The time-out period is 10
seconds.
➔ Check the connection of the network cable.
When executing the Terminate Communication, you cannot quit the
communication because other computer has an authority
Other computer has an authority.
When the parameter is set, the reserved port number is specified.
➔ Check the parameter setting (+p.90)
The projector might have turned off during the communication.
➔ Check the projector power and re-execute "Start communication".