Stylus Photo R300/R310
2.3.2 Removing Housing, Upper
External View
Damper Shaft
Installing Hole
C.B.P 3x8 (4-6kgf•cm)
Rib of Colour
LCD Cover
3
4
Housing, Upper
2
Carriage Unit
Carriage
Lock
Figure 2-3. Removing "Housing, Upper" (1)
DISASSEMBLY AND ASSEMBLY
Printer Cover
C.B.P 3x8 (4-6kgf•cm)
1
Hooks
Hooks
Figure 2-4. Removing "Housing, Upper" (2)
Parts/Units which should be removed before removing "Housing, Upper"
Paper Support Assy.
Procedure for Removing
1.
Push the damper shaft by putting in the tweezers or alike into the installing
hole of "Printer Cover". Then, remove "Printer Cover".
2.
Push up the rib of "Colour LCD Cover" and then remove "Colour LCD
Cover".
3.
Remove the screws (x4) which secure "Housing, Upper".
4.
Release "Carriage Lock" with the tweezers or alike and then move "Carriage
Unit" toward the centre.
5.
Release the hooks (x4) which secure "Housing, Upper" and then lift up
"Housing, Upper".
6.
Detach "Panel FFC" from the connector of "Panel Board" and then remove
"Housing, Upper".
Disassembly
Connector
Panel FFC
Revision A