Table 9 Host group modes (options) Windows
Host Group
Mode
6
13
40
CAUTION:
configured is disruptive and requires the server to be rebooted.

Setting the system option modes

The HP service representative sets the system option mode(s) based on the operating system and
software configuration of the host. Notify your HP representative if you install storage agnostic
software (such as backup or cluster software) that might require specific settings.

Configuring the Fibre Channel ports

Configure the disk array Fibre Channel ports by using Command View Advanced Edition or Remote
Web Console. Select the settings for each port based on your SAN topology. Use switch zoning
if you connect different types of hosts to the array through the same switch.

Installing and configuring the host

This section explains how to install and configure Fibre Channel adapters (FCAs) that connect the
host to the disk array.

Loading the operating system and software

Follow the manufacturer's instructions to load the operating system and software onto the host.
Load all OS patches and configuration utilities supported by HP and the FCA manufacturer.

Installing and configuring the FCAs

Install and configure the Fibre Channel adapter using the FCA manufacturer's instructions.
HP supplies driver, firmware, and BIOS downloads for commonly available FCAs. These downloads
contain FCA settings that are tested and approved by HP. To obtain a download, log onto the HP
website at
www.hp.com
file, and follow the installation instructions in the "readme" or documentation file supplied with
each download.
Contact your HP representative for current information on compatible FCAs.
32
Windows
Function
Parameter Setting Failure for TPRLO
When using the Emulex FCA in the Windows environment, the
parameter setting for TPRLO failed. After receiving TPRLO and
FCP_CMD, respectively. PRLO will respond when HostMode=0x0C/
0x2C and HostModeOption=0x06. (MAIN Ver.50-03- 1 4-00/00
and later)
SIM report at link failure.
Select HMO 13 when you want SIM notification when the number
of link failures detected between ports exceeds the threshold.
V-Vol expansion.
Select HMO 40 when all of the following conditions are satisfied:
The host mode 0C Windows or 2C Windows Extension is used.
You want to automate recognition of the DP-VOL capacity after
increasing the DP-VOL capacity.