Table 9 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKL0x) (continued)
Message ID
YKL080E MSG
SC=36 RC=36
(file:rec#)
YKL081W MSG
SC=16 RC=16
(pair-index)
YKL082W MSG
SC=8 RC=8
(pair-index)
YKL083W MSG
SC=12 RC=12
(pair-index)
66
Messages
Message Text
More than two DiskDevice
Elements in CopyPair.
Unable to resolve primary
device address.
Unable to resolve secondary
device address.
Unable to resolve volume
serial number.
Explanation and Recommended Actions
Only two copy pair elements are allowed: the first element for the
P-VOL and the second element for the S-VOL.
Check the line with the line number identified by rec# in the file
identified by file, and then identify the cause of the problem by
referring to information contained in the XML document type
definitions, in the HP StorageWorks P9000 for Business Continuity
Manager Software Reference Guide.
file
Name of the XML file where the error was
detected
rec#
Number of the line in the file identified by file
where the error was detected
The YKLOAD program failed to resolve the unit number (device
address) of the P-VOL in the specified CopyPair. For configuration
definition, this process uses the Host Discovered Array object in
the primary device address domain. For other purposes, the current
host device address domain is used. The situation represented by
this message is not always fatal. Some CLI commands, such as
YKSUSPND, can be successfully executed by using only the S-VOL
unit address.
pair-index
See the pair index description in the explanation of the YKE003E
message.
The YKLOAD program failed to resolve the unit number (device
address) of the S-VOL in the specified CopyPair. For configuration
definition, this process uses the Host Discovered Array object in
the secondary device address domain. For other purposes, the
current host device address domain is used. The situation
represented by this message is not always fatal. Many CLI
commands can be successfully executed by using only the P-VOL
unit address.
pair-index
See the pair index description in the
explanation of the YKE003E message.
The YKLOAD program failed to resolve the volume serial number
of the P-VOL in the specified CopyPair. For configuration definition,
this process uses the Host Discovered Array object in the primary
device address domain. For other purposes, the current host device
address domain is used. The situation represented by this message
is not always fatal. At present, the volume serial number is used
only for display and warning.
pair-index
See the pair index description in the
explanation of the YKE003E message.