HP StorageWorks P9000 Manual page 55

Business continuity manager software messages
Hide thumbs Also See for StorageWorks P9000:
Table of Contents

Advertisement

Table 8 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKG2x) (continued)
Message ID
Message Text
YKJ102E TSO
name is not specified in
RC=32
Copy Group definition
specified by BASEGROUP.
YKJ150E TSO
Error reported during file
RC=40
input/output. EXECIO RC=
n: dd-name
YKJ151E TSO
File format is invalid:
RC=40
DSORG= XX. DSORG must
be PS: dd-name
Explanation and Recommended Actions
The copy group definition file specified by the BASEGROUP
parameter does not include the element identified by name.
Set the necessary elements in the copy group definition file that is
to be used as the base, and then retry.
name
Name of an element in the copy group definition
file
Processing ended due to the EXECIO TSO/E REXX command
failure (return code = n). For details, see the TSO/E REXX User's
Guide.
The probable causes are as follows:
No CSV file is assigned to the DD name required for the
command.
The dataset format of the CSV file is not supported.
dd-name
DD name of the CSV file where the error was
detected
The dataset format of the CSV file identified by dd-name is invalid.
Delete the current CSV file and create a CSV file that is in the correct
dataset format.
For details about the CSV file dataset format, see the HP
StorageWorks P9000 for Business Continuity Manager Software
Reference Guide.
XX
DSORG of the CSV file where the error was
detected
dd-name
DD name of the CSV file where the error was
detected
List of Messages
55

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xp p9500

Table of Contents