Table 3 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKC0x) (continued)
Message ID
YKC009E MSG
SC=48 RC=48
YKC009E MSG
SC=48 RC=48
YKC010E TSO
RC=40
YKC031I MSG
SC=0 (count)
YKC032I MSG
SC=0 (count)
YKC033I MSG
SC=4 (count)
YKC034E MSG
SC=32 RC=32
YKC099I TSO
36
Messages
Message Text
Starting FROM() exceeds
ending TO()
Starting FROMVSN() exceeds
ending TOVSN()
REXX failure return
code=nnnn starting with
variable name
Scanned DASD Device Count
HP RAID Storage Systems
Found
The specified devices that do
not have any available I/O
paths were skipped.
A dynamic configuration
change was detected during
YKSCAN command
processing.
YKSCAN command return
code=nnnn, reason code=rrrr
Explanation and Recommended Actions
The value specified in the FROM parameter exceeds the value of
the TO parameter.
The value specified in the FROMVSN parameter exceeds the value
of the TOVSN parameter.
Access to the REXX variable identified by name failed.
For details about the return code, see IKJCT441 in the TSO/E
Programming Services.
nnnn
Error code returned upon REXX access
The number of DASD devices scanned by the YKSCAN command.
count
Number of scanned DASD devices
The number of HP RAID storage systems scanned by the YKSCAN
command.
count
Number of HP RAID storage systems
As a result of the device scan, information acquisition on devices
for which no I/O path is available was skipped.
count
The number of devices skipped when the device
information was acquired
A dynamic change to an I/O configuration definition was detected
during processing of the YKSCAN command. This error might have
been caused by the volume serial number in the acquired volume
information being different from the one in the actual configuration.
Check the disk configuration definition file after the scan is
complete. If the volume serial number is different from the one in
the actual configuration, re-execute the scan.
The YKSCAN command terminated with the return code nnnn and
the reason code rrrr.
This message is always displayed to indicate the return code and
the reason code.
nnnn
Maximum among the severity codes returned