Hp storageworks p9000 virtualization adapter release notes (5697-0681, october 2010) (4 pages)
Summary of Contents for HP StorageWorks P9000
Page 1
HP StorageWorks Business Continuity Manager Extended CT Group, and HP StorageWorks Business Continuity Manager Universal Replicator 4x4 Extended CTG. The intended audience is a storage system administrator or authorized service provider with independent knowledge of HP StorageWorks P9000 disk arrays and the HP StorageWorks Remote Web Console. HP Part Number: T5253-96048...
Contents 1 Messages....................4 Message Format........................4 Message Output Format......................4 Notations Used to Describe Messages..................5 Message Output Destination......................6 List of Messages........................6 Multi-line Messages Output to SYSTSPRT..................184 YK8310I PRT........................184 YK8312I PRT........................184 YK8314I PRT........................185 YK8316I PRT........................185 YK8318I PRT........................186 YK841 1I PRT........................186 YK8413I PRT........................187 User Completion Codes......................187 Identifying the Volume to Be Processed..................188 Identifying the Volume Serial Number from the REXX Script............188 Identifying the Volume Serial Number from the Configuration File...........188...
P9500 and XP disk arrays. The XP disk array copy products can be configured and controlled using the P9000 version of BCM. With the exception of TrueCopy Asynchronous, the HP product names are used in this manual. For compatibility with existing implementations on XP disk arrays, the Hitachi abbreviations shown in parenthesis are accepted by the user interface.
Information returned by the message. If the output destination is MSG, the value is set to the Severity in the message structure. For details about the message structure, see the HP StorageWorks P9000 for Business Continuity Manager Software Reference Guide.
If the MSG parameter is specified incorrectly, or an error occurs while the CLI command is using the REXX interface, the message will be sent to the user's TSO/E terminal. For details about the CLI commands, see the HP StorageWorks P9000 for Business Continuity Manager Software Reference Guide.
Page 7
Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YK80x) (continued) Message ID Message Text Explanation and Recommended Actions YK8008E CON BCM Monitor initialization An attempt to start BCM Monitor failed because of the reason failed: termination-code. indicated in a preceding message that was output to either the console or dd SYSTSPRT.
Page 8
Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YK80x) (continued) Message ID Message Text Explanation and Recommended Actions YK8017E CON Invalid command: There is an error in the command-name command. command-name. Make sure that the entered command is valid. YK8018E CON Operand is incorrect: There is an error in an operand of the command-name command.
Page 9
Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YK80x) (continued) Message ID Message Text Explanation and Recommended Actions YK8025E CON IRXJCL module error: The IRXJCL routine returned an error with the return code identified return-code. by return-code.
Page 10
Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YK80x) (continued) Message ID Message Text Explanation and Recommended Actions YK8027E CON IRXTERM module error: The IRXTERM routine returned an error with the return code code=return-code, identified by return-code. BCM Monitor will stop. R0=abnormal-termination-code-and- Check the return code.
Page 11
Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YK80x) (continued) Message ID Message Text Explanation and Recommended Actions YK8028E CON BCM Monitor function The main task or subtask terminated abnormally during BCM abend: code=Sxxx Uxxxx Monitor processing.
Page 12
Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YK80x) (continued) Message ID Message Text Explanation and Recommended Actions YK8040I PRT CON time BCM Monitor will stop BCM Monitor will stop at the point label. at STOPPOINT 'label'. time Message output time This is only displayed when the output...
Page 13
Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YK80x) (continued) Message ID Message Text Explanation and Recommended Actions YK8046I PRT CON time Execute operator BCM Monitor will execute the operator command identified by command 'opcmd'. opcmd.
Page 14
Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YK80x) (continued) Message ID Message Text Explanation and Recommended Actions YK8055I PRT CON time BCM Monitor will BCM Monitor will go to sleep because the PAUSE action was pause now for ‘sleep-time’...
Page 15
Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YK80x) (continued) Message ID Message Text Explanation and Recommended Actions YK8074E PRT time A FREEMAIN error A FREEMAIN error occurred. The program will stop running. occurred. return code=nnn. Contact technical support for assistance.
Page 16
Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YK80x) (continued) Message ID Message Text Explanation and Recommended Actions YK8078E PRT time A required parameter The required parameter param-name is not specified. is missing : file : time param-name.
Page 17
Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YK80x) (continued) Message ID Message Text Explanation and Recommended Actions YK8083E PRT time The corresponding The copy group cgid specified in the ACTION parameter of the CGID parameter is not YKMONCG file is not defined.
Page 18
Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YK80x) (continued) Message ID Message Text Explanation and Recommended Actions YK8220E PRT CON time cmd error for Copy An error occurred during execution of the cmd command for the Group 'cgid' copy group identified by cgid.
Page 19
Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YK80x) (continued) Message ID Message Text Explanation and Recommended Actions YK8230E PRT CON time REPORT type is only type, which was specified for the REPORT parameter, is only valid valid for TCA or CAJ Copy for TCA or Cnt Ac-J Z copy groups.
Page 20
Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YK80x) (continued) Message ID Message Text Explanation and Recommended Actions YK8304I PRT CON time Copy Group is in BCM Monitor will wait until the copy group status identified by 'status' status.
Page 21
Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YK80x) (continued) Message ID Message Text Explanation and Recommended Actions YK831 1I CON REPORT SUMMARY: This message indicates the results of REPORT(SUMMARY). COPY GROUP : cgid cgid TYPE : cgtype Copy group ID DAD-ID : dad PREFIX : prefix...
Page 22
Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YK80x) (continued) Message ID Message Text Explanation and Recommended Actions YK8313I CON REPORT DETAIL: This message indicates the results of REPORT(DETAIL). COPY GROUP : cgid TYPE cgid : cgtype Copy group ID DAD-ID : dad PREFIX : prefix...
Page 23
Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YK80x) (continued) Message ID Message Text Explanation and Recommended Actions YK8315I CON REPORT RPO: This message indicates the results of REPORT(RPO). COPY GROUP : cgid cgid C/T SUBC/T PSN SSN Copy group ID DELTA CTTIME ctid...
Page 24
Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YK80x) (continued) Message ID Message Text Explanation and Recommended Actions YK8317I CON REPORT STATS: This message indicates the results of REPORT(STATS) for the TCA copy group. COPY GROUP : cgid TYPE : cgtype cgid DAD-ID : dad PREFIX : prefix...
Page 25
Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YK80x) (continued) Message ID Message Text Explanation and Recommended Actions YK8318I “YK8318I PRT” (page 186). YK8319I CON REPORT STATS: This message indicates the results of REPORT(STATS) for the Cnt Ac-J Z copy group.
Page 26
Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YK80x) (continued) Message ID Message Text Explanation and Recommended Actions YK8321I PRT CON time Some volumes are in a Some volumes are in the TRANSITION status. 'TRANSITION' status. time Message output time This is only displayed when the output...
Page 27
Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YK80x) (continued) Message ID Message Text Explanation and Recommended Actions YK8401I PRT CON time Check Startup Status of BCM Monitor will start checking the status of the copy group Copy Group 'cgid'.
Page 28
Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YK80x) (continued) Message ID Message Text Explanation and Recommended Actions YK8410I PRT CON time ---- date ---- The date is displayed when BCM Monitor is started or when the date changes while BCM Monitor is running.
Page 29
If necessary, recreate the license information dataset and re-register the license keys in the order in which they were issued. For details about registering a prefix name of the license information dataset, see the HP StorageWorks P9000 for Business Continuity Manager Software Reference Guide. YK9052E ISPF An error occurred in the An error occurred with the license key dataset.
Page 30
Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YK80x) (continued) Message ID Message Text Explanation and Recommended Actions YK9071W ISPF A license key was not found An attempt was made to install a license key, but no installation license key was found in the license key dataset.
Page 31
Table 2 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKA0x) (continued) Message ID Message Text Explanation and Recommended Actions YKA002E TSO HANDLE() parameter The OP(GET) and OP(CLOSE) requests require the HANDLE required for this operation parameter to be specified. Use the handle value returned by the OP(OPEN) request in the YKA098I message.
Page 32
Table 2 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKA0x) (continued) Message ID Message Text Explanation and Recommended Actions YKB001I TSO YKP2B completed. The YKP2B command terminated. RC=return-code return-code The return code of the YKP2B command 0: The command ended successfully.
Page 33
Table 2 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKA0x) (continued) Message ID Message Text Explanation and Recommended Actions YKB102E TSO Error occurred during An error occurred during execution of the YKP2B command. execution. See the explanation corresponding to the message ID of the error Cmd=command-name message indicated by message-text and take appropriate action.
Page 34
Table 2 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKA0x) (continued) Message ID Message Text Explanation and Recommended Actions YKB202W TSO Unable to resolve primary A P-VOL not defined in the disk configuration definition file was volume information.
Page 35
Table 2 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKA0x) (continued) Message ID Message Text Explanation and Recommended Actions YKC001E MSG No controller ARRAYS() Nothing is assigned to the ARRAYS parameter. SC=48 RC=48 supplied YKC001E TSO No message MSG() supplied Nothing is assigned to the MSG parameter.
Page 36
Table 3 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKC0x) (continued) Message ID Message Text Explanation and Recommended Actions YKC009E MSG Starting FROM() exceeds The value specified in the FROM parameter exceeds the value of SC=48 RC=48 ending TO() the TO parameter.
Page 37
Table 4 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKD0x) Message ID Message Text Explanation and Recommended Actions YKD000T TSO Supplied parameters invalid Invalid parameters are specified. RC=48 For details, see the reason code in the YKD099I message that will appear after this message.
Page 38
Table 5 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKE0x) Message ID Message Text Explanation and Recommended Actions YKE000T TSO Supplied parameters invalid Invalid parameters are specified. RC=48 For details, see the reason code in the YKE099I message that will appear after this message.
Page 39
Table 5 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKE0x) (continued) Message ID Message Text Explanation and Recommended Actions YKE003E MSG Unexpected transition of The copy pair in the copy group entered an unexpected status. SC=8 RC=8 group copy-group pair index Check that the status to be monitored is correctly specified.
Page 40
Table 6 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKF0x) (continued) Message ID Message Text Explanation and Recommended Actions YKF002E TSO Messages MSG(stem) does The last character of the MSG parameter is not a period. RC=48 not include trailing "."...
Page 41
Check the indicated line, and then identify the cause of the problem by referring to information contained in the XML document type definitions, in the HP StorageWorks P9000 for Business Continuity Manager Software Reference Guide. file Name of the XML file where the error was...
Page 42
(file:rec#) Check the indicated line, and then identify the cause of the problem by referring to information contained in the XML document type definitions, in the HP StorageWorks P9000 for Business Continuity Manager Software Reference Guide. string Character string where the error was detected...
Page 43
Check the indicated line, and then identify the cause of the problem by referring to information contained in the XML document type definitions, in the HP StorageWorks P9000 for Business Continuity Manager Software Reference Guide. file...
Page 44
Check the indicated line, and then identify the cause of the problem by referring to information contained in the XML document type definitions, in the HP StorageWorks P9000 for Business Continuity Manager Software Reference Guide. file...
Page 45
Table 7 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKG0x) (continued) Message ID Message Text Explanation and Recommended Actions YKG090E MSG File Allocation Failed: dsstate. An attempt to allocate the XML file identified by file failed. SC=40 RC=40 dsstate (file)
Page 46
Table 8 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKG2x) (continued) Message ID Message Text Explanation and Recommended Actions YKG241W MSG The attribute attname is The XML attribute identified by attname has already been defined. SC=4 RC=4 already defined.
Page 47
Table 8 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKG2x) (continued) Message ID Message Text Explanation and Recommended Actions YKG253E MSG This kind of elements The XML element element cannot be defined more than once. SC=36 RC=36 element can't be defined Correct the specification on the line with the line number identified (file:rec#)
Page 48
Table 8 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKG2x) (continued) Message ID Message Text Explanation and Recommended Actions YKG274E MSG ETag name is mismatch. The specified ETag name /incorrect-ETag-name is not the expected SC=36 RC=36 /correct-ETag-name is ETag name /correct-ETag-name.
Page 49
DAD() parameter. Specify the local device address domain ID of the primary site in the DAD parameter. For details about the NG scan, see the HP StorageWorks P9000 for Business Continuity Manager Software Reference Guide. file Name of the XML file where the error was...
Page 50
Table 8 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKG2x) (continued) Message ID Message Text Explanation and Recommended Actions YKG298E MSG YKGETHDA encountered an An unexpected error has occurred. TSO SC=44 RC=44 unexpected error. This error might have occurred with another error. (detailed-info) If another error message was output at the same time as this one, follow the instructions in that message to fix the corresponding...
Page 51
Table 8 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKG2x) (continued) Message ID Message Text Explanation and Recommended Actions YKH002I TSO No copy pair was No copy pairs were detected within the specified range. discovered. Check the operating range and status of the copy pair that you want to acquire, and execute the YKH2B command again.
Page 52
Table 8 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKG2x) (continued) Message ID Message Text Explanation and Recommended Actions YKH201W TSO No I/O paths are available No copy pair information was acquired from the volume to which for the specified devices.
Page 53
Table 8 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKG2x) (continued) Message ID Message Text Explanation and Recommended Actions YKH205W TSO This copygroup does not Cnt Ac-S Z with the HyperSwap attribute cannot be used in this support LinkageOption=HS.
Page 54
Table 8 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKG2x) (continued) Message ID Message Text Explanation and Recommended Actions YKJ051E TSO Error occurred during An error occurred during execution of the YKIMPORT command RC=32 execution. Cmd= info or YKEXPORT command.
Page 55
Delete the current CSV file and create a CSV file that is in the correct be PS: dd-name dataset format. For details about the CSV file dataset format, see the HP StorageWorks P9000 for Business Continuity Manager Software Reference Guide. DSORG of the CSV file where the error was detected...
Page 56
See the information output in the message to review the environment, and then update the CSV file again. For details about troubleshooting, see the accompanying message and the HP StorageWorks P9000 for Business Continuity Manager Software User Guide. dd-name DD name of the CSV file where the error was...
Page 57
Table 8 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKG2x) (continued) Message ID Message Text Explanation and Recommended Actions YKJ202I TSO RC=4 No copy pair is defined in No copy pair is defined in the pair information CSV file. No data specified Pair information was written in the copy group definition file.
Page 58
Table 8 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKG2x) (continued) Message ID Message Text Explanation and Recommended Actions YKJ207W TSO Inconsistencies exist among The P-VOL specified with the device number differs from the P-VOL RC=8 the values used to specify specified with the storage system serial number, CU number, and the primary volume:...
Page 59
Table 8 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKG2x) (continued) Message ID Message Text Explanation and Recommended Actions YKJ21 1E TSO PVOL & SVOL of Hitachi A copy pair, which has a P-VOL storage system serial number and RC=32 ShadowImage™...
Page 60
Table 8 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKG2x) (continued) Message ID Message Text Explanation and Recommended Actions YKJ251E TSO The value value of name in The format of the value assigned to name in the EXCTG information RC=32 EXCTG information CSV file CSV file is invalid.
Page 61
Table 8 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKG2x) (continued) Message ID Message Text Explanation and Recommended Actions YKJ256E TSO This entry does not have any The pair information CSV file includes no entry (line) corresponding RC=32 corresponding Copy Group to the entry (line) specified in the EXCTG information CSV file.
Page 62
Table 8 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKG2x) (continued) Message ID Message Text Explanation and Recommended Actions YKK101E TSO Failed to get security setting Security setting information could not be acquired. RC=32 information, service-name service=service-name, Name of the OS service that encountered an code=code1, code2.
Page 63
Check the indicated line, and then identify the cause of the problem by referring to information contained in the XML document type definitions, in the HP StorageWorks P9000 for Business Continuity Manager Software Reference Guide. file...
Page 64
Check the indicated line, and then identify the cause of the problem by referring to information contained in the XML document type definitions, in the HP StorageWorks P9000 for Business Continuity Manager Software Reference Guide. file Name of the XML file where the error was...
Page 65
Check the indicated line, and then identify the cause of the problem by referring to information contained in the XML document type definitions, in the HP StorageWorks P9000 for Business Continuity Manager Software Reference Guide. name XML attribute name...
Page 66
Check the line with the line number identified by rec# in the file identified by file, and then identify the cause of the problem by referring to information contained in the XML document type definitions, in the HP StorageWorks P9000 for Business Continuity Manager Software Reference Guide. file...
Page 67
Table 9 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKL0x) (continued) Message ID Message Text Explanation and Recommended Actions YKL085E MSG Unable to read configuration The configuration file could not be read, because the record length SC=40 RC=40 (file) file.
Page 68
Table 9 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKL0x) (continued) Message ID Message Text Explanation and Recommended Actions YKL092E MSG File Read error: dsstate. An attempt to read the XML file identified by file failed. SC=40 RC=40 (file) dsstate Status of the input XML...
Page 69
Table 10 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKL2x) (continued) Message ID Message Text Explanation and Recommended Actions YKL250E MSG The value value of the The value value of the XML attribute name is in an invalid format. SC=36 RC=36 attribute name is an invalid Correct the specification on the line with the line number identified...
Page 70
The host ID that identifies the host on which Business Continuity Manager is running is invalid or missing. Define YKCMDIF correctly. For details on the host ID definition (YKCMDIF), see the HP StorageWorks P9000 for Business Continuity Manager Software Installation Guide. YKL271E MSG The element name is required, The required XML element name is missing.
Page 71
Table 10 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKL2x) (continued) Message ID Message Text Explanation and Recommended Actions YKL274E MSG ETag name is mismatch. The specified ETag name /incorrect-ETag-name is not the expected SC=36 RC=36 /correct-ETag-name is ETag name /correct-ETag-name.
Page 72
Table 10 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKL2x) (continued) Message ID Message Text Explanation and Recommended Actions YKL281E MSG No command device of the No command device is found that corresponds to the storage SC=36 RC=36 storage system in remote system defined in the route for remote command issuance.
Page 73
Table 10 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKL2x) (continued) Message ID Message Text Explanation and Recommended Actions YKL292E MSG The expiration date for your The license (function) has expired. CON SC=36 license key(function). To continue using this product, you need a permanent license. RC=36 If function is Basic: A permanent license for Business Continuity Manager Basic is...
Page 74
Table 10 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKL2x) (continued) Message ID Message Text Explanation and Recommended Actions YKL298E MSG TSO CLI-name encountered an An unexpected error has occurred. This error might have occurred SC=44 RC=44 unexpected error.
Page 75
Table 1 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKM0x) (continued) Message ID Message Text Explanation and Recommended Actions YKM002E TSO Messages MSG(stem) does The last character of the MSG parameter is not a period. not include trailing "."...
Page 76
Table 1 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKM0x) (continued) Message ID Message Text Explanation and Recommended Actions YKM021E ISPF Check either Device num or Select either Device Num or Volser. Volser YKM022E ISPF The End Volser value must not The End Volser value is lower than the Start Volser value.
Page 77
Table 1 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKM0x) (continued) Message ID Message Text Explanation and Recommended Actions YKM040E ISPF A Consistency Group ID (C/T For the Cnt Ac-J Z copy group definition, you need to specify a ID,sub C/T ID) is required for C/T group ID and a sub C/T group ID.
Page 78
NG scan. For details about not found by remote scan or the NG scan, see the HP StorageWorks P9000 for Business NG scan. Continuity Manager Software Reference Guide.
Page 79
Table 12 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKM1x – YKM5x) (continued) Message ID Message Text Explanation and Recommended Actions YKM505E ISPF This inter-DKC path is already This inter-DKC path is already defined in another logical path. defined in another logical path.
Page 80
Table 12 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKM1x – YKM5x) (continued) Message ID Message Text Explanation and Recommended Actions YKM519E ISPF You cannot insert a remote A remote route entry cannot be inserted because the specified route entry, either because the device address domain ID is the same as the local device specified DAD ID is the same...
Page 81
Table 13 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKM7x) (continued) Message ID Message Text Explanation and Recommended Actions YKM703E ISPF Enter hexadecimal characters Enter hexadecimal characters (0-9, A-F, a-f). (0-9, A-F, a-f). YKM704E ISPF Enter alphanumeric characters Enter alphanumeric characters (0-9, A-Z, a-z).
Page 82
Table 13 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKM7x) (continued) Message ID Message Text Explanation and Recommended Actions YKM731E ISPF service error occurred. An error occurred in the ISPF service. info info Maintenance information YKM750E ISPF Serial number must be a 5-digit Serial numbers must be a 5-digit combination of alphanumeric combination of alphanumeric...
Page 83
DADID matches a local or domain ID or remote device address domain ID. For details remote DADID. about the NG scan, see the HP StorageWorks P9000 for Business Continuity Manager Software Reference Guide. YKM763E ISPF You cannot perform a NG...
Page 84
If DBCS (Double-Byte Character Set) is enabled for the environment, concatenate the Business Continuity Manager dataset to the alternate message library (dd name: ISPMALT). For details, see the HP StorageWorks P9000 for Business Continuity Manager Software Installation Guide. YKM905E TSO A GETMAIN error occurred.
Page 85
Table 15 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKN0x) (continued) Message ID Message Text Explanation and Recommended Actions YKN010E TSO REXX failure return code=nnnn Access to the REXX variable identified by name failed. RC=40 starting with variable name For details about the return code, see IKJCT441 in the TSO/E Programming Services.
Page 86
Table 16 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKP0x) (continued) Message ID Message Text Explanation and Recommended Actions YKP003E MSG SC=48 Some storage systems in this The TCA copy group on which the YKSTATS command has RC=48 Copy Group do not support been executed contains an unsupported IFType.
Page 87
Table 17 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKQ0x) (continued) Message ID Message Text Explanation and Recommended Actions YKQ003E MSG Parameters combination is The parameter combination is invalid. SC=48 invalid YKQ008E MSG DEVN() not valid hex The value specified in the DEVN parameter is not in SC=48 hexadecimal format.
Page 88
Table 17 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKQ0x) (continued) Message ID Message Text Explanation and Recommended Actions YKQ019W MSG Primary volume serial changed. Although the P-VOL is online, the current volume serial SC=12 RC=0 DEVN device#(SN,CU#,CCA#) number does not match the volume serial number defined (pair-index)
Page 89
Table 17 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKQ0x) (continued) Message ID Message Text Explanation and Recommended Actions YKQ026W MSG SC=8 Primary volume is offline. DEVN The volume serial number of the P-VOL cannot be obtained RC=8 (pair-index) device#(SN,CU#,CCA#) because the P-VOL is offline.
Page 90
Table 18 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKR0x) (continued) Message ID Message Text Explanation and Recommended Actions YKR002E MSG SC=48 Copy Group STEM(stem) does The last character of the STEM parameter is not a period. RC=48 not include trailing "."...
Page 91
Table 19 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKS0x) Message ID Message Text Explanation and Recommended Actions YKS001E TSO RC=48 Unable to execute without valid Specify a valid MSG parameter. MSG() parameter. YKS002E TSO RC=48 MSG(stem) does not include The last character of the MSG parameter is not a period.
Page 92
Creation of a configuration file failed. Check the free device capacity and the available size of VTOC. For details about the required device capacity for a configuration file, see the HP StorageWorks P9000 for Business Continuity Manager Software Reference Guide.
Page 93
The prefix of the REXX variable name specified in the RC=36 CopyGroup object. STEM parameter does not comply with the copy group structure described in the HP StorageWorks P9000 for Business Continuity Manager Software Reference Guide. YKS099I MSG TSO YKSTORE Processing Complete.
Page 94
For details about what action to take, see the message that was output and the HP StorageWorks P9000 for Business Continuity Manager Software User’s Guide. operation The operation performed for the configuration file...
Page 95
Table 20 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKS2x) (continued) Message ID Message Text Explanation and Recommended Actions YKS290E MSG SC=44 YKVGET program failure for:vn An attempt to acquire the variable vn failed with the result RC=44 (result) value identified by result.
Page 96
Table 21 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKT0x) (continued) Message ID Message Text Explanation and Recommended Actions YKT006W CON RC=16 Couldn't delete name/token Name/Token deletion failed. Contact technical support for assistance. YKT007W CON RC=16 Couldn't delete SVC entry SVC number deletion failed in the SVCUPDTE macro.
Page 97
Table 22 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKT2x) (continued) Message ID Message Text Explanation and Recommended Actions YKT212E CON RC=12 Couldn't register Name/Token An error occurred during Name/Token registration. The program stops processing. Contact technical support for assistance. YKT213E CON RC=4 Couldn't take Name/Token An error occurred during acquisition of Name/Token.
Page 98
Table 22 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKT2x) (continued) Message ID Message Text Explanation and Recommended Actions YKT232E CON RC=12 The task is not APF-authorized. The dataset name of the Business Continuity Manager load library is not registered in SYS1.PARMLIB. Alternately, the execution of the command has failed because authorized/unauthorized datasets co-existed while concatenating DD statements in the load library...
Page 99
Table 23 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKT4x) (continued) Message ID Message Text Explanation and Recommended Actions YKT402I CON varname = value1 (symbol = This message displays Business Continuity Manager value2) environment variable details. varname Name of the Business Continuity Manager environment variable that...
Page 100
The time value assigned to the ATTIME parameter is RC=48 invalid. invalid. For the correct format, see the description of the YKSUSPND command in the HP StorageWorks P9000 for Business Continuity Manager Software Reference Guide. attime Time value assigned to the ATTIME...
Page 101
Table 24 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKU0x) (continued) Message ID Message Text Explanation and Recommended Actions YKU054E MSG SC=36 ATTIME parameter invalid for CA The YKSUSPND command with the ATTIME parameter RC=48 Copy Group specified was executed on a Cnt Ac-S Z copy group.
Page 102
Table 25 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKV0x) (continued) Message ID Message Text Explanation and Recommended Actions YKV002E MSG SC=48 DEVN() value invalid The value assigned to the DEVN parameter is invalid. YKV002E TSO RC=48 Messages MSG(stem) does not The last character of the MSG parameter is not a period.
Page 103
Return code of YKLOAD command For details, see the description for the YKLOAD command in the HP StorageWorks P9000 for Business Continuity Manager Software Reference Guide. YKW007E TSO YKQUERY error return code = The YKWATCH command uses the YKQUERY command nnnn.
Page 104
YKWATCH command cannot be executed correctly. rrrr Return code of the YKCONMSG command For details, see the description for the YKCONMSG command in the HP StorageWorks P9000 for Business Continuity Manager Software Reference Guide. YKW098E TSO Invalid parameter-reason-message The YKWATCH command detected an invalid startup parameter.
Page 105
Table 27 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKX0x) (continued) Message ID Message Text Explanation and Recommended Actions YKX065W MSG SC=4 Storage system serial-number The command device definition for the storage system RC=0 Command Device Definition identified by serial-number failed.
Page 106
The specified parameter combination is invalid. For details about the combination of parameters, see the description of the YKDELCMD command in the HP StorageWorks P9000 for Business Continuity Manager Software Reference Guide. YKX104E MSG SC=48 Device# DEVN() is not found...
Page 107
The specified parameter combination is invalid. For details about the combination of parameters, see the description of the YKQRYDEV command in the HP StorageWorks P9000 for Business Continuity Manager Software Reference Guide. YKX204E MSG SC=48 Device# DEVN() is not found...
Page 108
Table 30 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKY0x) Message ID Message Text Explanation and Recommended Actions YKY001I CON AGENT STARTED (vv-rr[-zz]) The Business Continuity Manager agent has started. Version number Revision number Exception YKY002I CON INVALID INITIALIZATION The specified parameter has not been defined in the PARAMETER: parameter-name...
Page 109
Table 30 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKY0x) (continued) Message ID Message Text Explanation and Recommended Actions YKY016I CON TASK(task-ID) ABENDED,CODE= A task terminated abnormally during the agent start up. The Business Continuity Manager agent will be completion-code terminated.
Page 110
Table 31 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKY1x) Message ID Message Text Explanation and Recommended Actions YKY100I CON MODIFY COMMAND The MODIFY command was accepted. ACCEPTED YKY101I CON STOP COMMAND ACCEPTED The STOP command was accepted. YKY102I CON INVALID error-type: text After an entry of the MODIFY command, an error was...
Page 111
Table 31 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKY1x) (continued) Message ID Message Text Explanation and Recommended Actions YKY131I CON host-type PORT=port-number This message displays the port number and IP address HOST=IP-address of the local or remote host. This message is followed by the TCP/IP session information.
Page 112
Table 32 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKY3x) Message ID Message Text Explanation and Recommended Actions YKY300I SYS hh:mm:ss task-ID,TCP The TCP connection request was accepted. Information CONNECTION ACCEPTED about the communication with the remote host is displayed in the YKY307I message.
Page 113
Table 32 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKY3x) (continued) Message ID Message Text Explanation and Recommended Actions YKY307I SYS hh:mm:ss task-ID,TCP The TCP connection request was accepted. CONNECTION INFORMATION, Take appropriate action according to the message REMOTE-HOST=IP-address, that was displayed before this message.
Page 114
Table 32 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKY3x) (continued) Message ID Message Text Explanation and Recommended Actions YKY315I CON task-ID,COMMUNICATION A communication error was detected. The message ERROR,@API[,request-name displays the request name, the target IP address:target port number (decimal number), and the local IP [,RC=response-code]] address:local port number (decimal number).
Page 115
Table 32 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKY3x) (continued) Message ID Message Text Explanation and Recommended Actions YKY321I CON task-ID,COMMUNICATION TIMED There is no response within the specified response wait time. The connection will be released. Check the cause of the response timeout.
Page 116
Change the name of the temporary file to the name indicated by file. For details on names of temporary files, see the chapter that explains linking with Replication Manager in the HP StorageWorks P9000 for Business Continuity Manager Software Installation Guide. Restart the Business Continuity Manager agent, and then refresh the configuration file from Replication Manager.
Page 117
Table 32 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKY3x) (continued) Message ID Message Text Explanation and Recommended Actions YKY503E XML Temporary file error-type error. file An error occurred in the temporary file. Check whether the temporary file indicated by file exists. If the error type is RENAME and the temporary file exists, change the name of the temporary file to the name of the configuration file that you want to update.
Page 118
Table 33 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKY6x) Message ID Message Text Explanation and Recommended Actions YKY600I CON INSUFFICIENT SPACE AVAILABLE. The area allocation by the Business Continuity maintenance-information Manager agent failed. The Business Continuity Manager agent will be terminated.
Page 119
Table 33 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKY6x) (continued) Message ID Message Text Explanation and Recommended Actions YKY605I CON IRXINIT MODULE The IRXINIT routine returned an error with the return ERROR,CODE=return-code, code shown as return-code. The Business Continuity Manager agent will terminate the processing.
Page 120
Table 33 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKY6x) (continued) Message ID Message Text Explanation and Recommended Actions YKY606I CON IRXTERM MODULE The IRXTERM routine returned an error with the ERROR,CODE=return-code,R0= indicated return code. The Business Continuity Manager agent terminates the processing.
Page 121
Table 33 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKY6x) (continued) Message ID Message Text Explanation and Recommended Actions YKY699I CON AGENT FUNCTION ABEND The main task or subtask terminated abnormally during CODE=Sxxx Uxxxx the Business Continuity Manager agent processing. If DATE=yy-mm-dd TIME=hh:mm:nn the task cannot be recovered, the Business Continuity Manager agent will be terminated.
Page 122
Table 33 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKY6x) (continued) Message ID Message Text Explanation and Recommended Actions pppppppp pppppppp PSW during the abnormal termination Length of command during the abnormal termination Interrupt code during the abnormal termination Table 34 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKY7x)
Page 123
Table 34 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKY7x) (continued) Message ID Message Text Explanation and Recommended Actions YKY715E XML An invalid value was specified for An invalid value was specified for parameter-name the parameter 'parameter-name' in in the XML request element element-name.
Page 124
Table 34 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKY7x) (continued) Message ID Message Text Explanation and Recommended Actions YKY726E XML Configuration file error CGname The copy group definition information could not be 'cgname' error-type. acquired because the error indicated by error-type occurred in the configuration file.
Page 125
Table 34 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKY7x) (continued) Message ID Message Text Explanation and Recommended Actions YKY730E XML INVALID CT Group is specified. The specified consistency group is invalid. Make sure that the specified consistency group exists in the copy group definition file.
Page 126
Table 35 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ0x) (continued) Message ID Message Text Explanation and Recommended Actions YKZ066E MSG SC=48 Necessary Route List is not found. The route list to be processed cannot be found. RC=48 Check the ROUTE parameter, DAD parameter, route list definition file, and command device definition file...
Page 127
Table 36 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ10x – YKZ20x) Message ID Message Text Explanation and Recommended Actions YKZ103E MSG SC=48 Parameters combination is invalid The parameter combination is invalid. YKZ201E MSG CON PRT A GETMAIN error occurred.
Page 128
Table 36 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ10x – YKZ20x) (continued) Message ID Message Text Explanation and Recommended Actions YKZ202E MSG TSO A Logical error occurred. (reason Logical contradiction occurred. CON SC=52 RC=0 code=nnn, cmd=xxx, pos=yyy) nnn (decimal number) Reason code (maintenance information)
Page 129
Table 36 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ10x – YKZ20x) (continued) Message ID Message Text Explanation and Recommended Actions YKZ204E TSO RC=40 A REXX write error occurred. (return The command cannot be executed because a REXX code=nnn, name= name, write error occurred.
Page 130
Table 36 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ10x – YKZ20x) (continued) Message ID Message Text Explanation and Recommended Actions YKZ206E TSO RC=0 An I/O error occurred. The command cannot be executed because an I/O (detail=message-text, cmd=xxx, error occurred.
Page 131
Table 36 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ10x – YKZ20x) (continued) Message ID Message Text Explanation and Recommended Actions YKZ207E MSG TSO A Core process error occurred. CON SC=52 RC=44 (detail=message-text, cmd=xxx, pos=yyy) List of Messages...
Page 132
Table 36 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ10x – YKZ20x) (continued) Message ID Message Text Explanation and Recommended Actions The command cannot be executed because a Core processing error occurred. message-text (string) Message text The message text will be as shown below: If an OS macro error occurred:...
Page 133
Table 36 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ10x – YKZ20x) (continued) Message ID Message Text Explanation and Recommended Actions Maintenance information If this message is output when the log and trace are obtained, the RC is 0. YKZ208I TSO CON PRT The Core processing ( process ) Core processing is starting.
Page 134
Table 37 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ21x – YKZ24x) Message ID Message Text Explanation and Recommended Actions YKZ210E MSG TSO A NAME/TOKEN read error The command cannot be executed because a CON SC=40 RC=44 occurred.
Page 135
Table 37 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ21x – YKZ24x) (continued) Message ID Message Text Explanation and Recommended Actions YKZ212W CON RC=0 A FREEMAIN error occurred. (return A FREEMAIN error occurred. code=nnn, cmd=xxx, pos=yyy) nnn (decimal number) Return code of the FREEMAIN macro...
Page 136
Table 37 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ21x – YKZ24x) (continued) Message ID Message Text Explanation and Recommended Actions YKZ216E TSO RC=0 The Trace table is not initialized. The trace table is not initialized. (cmd=xxx, pos=yyy) xxx (decimal number) Command code of the command...
Page 137
Table 37 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ21x – YKZ24x) (continued) Message ID Message Text Explanation and Recommended Actions YKZ219W CON RC=0 A LOAD error occurred. (return A LOAD macro error occurred. code=nnn, reason code=mmm, nnn (decimal number) name=name, cmd=xxx, pos=yyy) Return code from the LOAD macro...
Page 138
Table 37 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ21x – YKZ24x) (continued) Message ID Message Text Explanation and Recommended Actions YKZ220T MSG SC=36 Number of pair-groups value null or The number of copy pairs contained in the copy RC=36 invalid.
Page 139
Table 37 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ21x – YKZ24x) (continued) Message ID Message Text Explanation and Recommended Actions YKZ224E MSG SC=12 Secondary device does not support TCA cannot be used on a storage system with an RC=36 (pair-index) S-VOL.
Page 140
Table 37 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ21x – YKZ24x) (continued) Message ID Message Text Explanation and Recommended Actions YKZ228E MSG SC=36 Invalid pair attribute name = value The value of the REXX variable is invalid. RC=36 (pair-index) Check that the value is specified according to the...
Page 141
Table 37 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ21x – YKZ24x) (continued) Message ID Message Text Explanation and Recommended Actions YKZ230W MSG SC=4 Management for the relevant volume Processing for the volume was skipped because the RC=4 (pair-index) was skipped.
Page 142
Table 37 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ21x – YKZ24x) (continued) Message ID Message Text Explanation and Recommended Actions YKZ233E MSG SC=36 Invalid Copy Group attribute name The specified copy group attribute value is invalid RC=36 (attribute-value) for this command.
Page 143
Table 37 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ21x – YKZ24x) (continued) Message ID Message Text Explanation and Recommended Actions YKZ239E MSG SC=48 The specified Copy Group has no The specified copy group is not a Cnt Ac-S Z with a RC=48 CA Synchronous Group.
Page 144
Table 37 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ21x – YKZ24x) (continued) Message ID Message Text Explanation and Recommended Actions YKZ247E MSG SC=44 STEM(stem) information for Core Information on the specified stem name is missing. RC=44 Processing is not found.
Page 145
Table 38 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ25x) Message ID Message Text Explanation and Recommended Actions YKZ250E MSG SC=40 A NAME/TOKEN delete error The command cannot be executed because a RC=44 occurred. (return code=nnn, name= NAME/TOKEN delete error occurred.
Page 146
Table 38 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ25x) (continued) Message ID Message Text Explanation and Recommended Actions Business Continuity Manager failed to complete the requested processing. Processing will continue with this device skipped. Check the status of the error device, correct any errors related to the configuration or execution conditions, and then re-execute the command.
Page 147
Table 38 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ25x) (continued) Message ID Message Text Explanation and Recommended Actions YKZ252E MSG SC=8 DASD device Business Continuity Manager failed to complete the RC=8 device-number- 1 (device-number-2) requested processing. management error, message-text.
Page 148
Table 38 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ25x) (continued) Message ID Message Text Explanation and Recommended Actions YKZ253E MSG SC=32 DASD device An I/O error occurred. Processing will continue with RC=32 (pair-index) device-number- 1 (device-number-2) this device skipped.
Page 149
Table 38 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ25x) (continued) Message ID Message Text Explanation and Recommended Actions YKZ254E MSG SC=8 DASD device An I/O error occurred. Business Continuity Manager RC=8 device-number- 1 (device-number-2) might not support this device. Processing will continue I/O error.
Page 150
Table 38 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ25x) (continued) Message ID Message Text Explanation and Recommended Actions YKZ255E MSG SC=32 DASD device Detailed information on the I/O error is displayed. RC=32 (pair-index) device-number- 1 (device-number-2) device-number- 1 (string) sense: diagnostic-information The device that issued I/O...
Page 151
Table 38 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ25x) (continued) Message ID Message Text Explanation and Recommended Actions YKZ257E MSG SC=32 DASD device Business Continuity Manager failed to complete the RC=32 (pair-index) device-number- 1 (device-number-2) requested processing.
Page 152
Table 38 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ25x) (continued) Message ID Message Text Explanation and Recommended Actions YKZ258E MSG SC=8 DASD device Business Continuity Manager failed to complete the RC=8 device-number- 1 (device-number-2) requested processing. Business Continuity Manager management error.
Page 153
Table 39 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ26x) Message ID Message Text Explanation and Recommended Actions YKZ260I MSG SC=0 The volume has already reached the Processing of some volumes was skipped because a RC=0 target status.
Page 154
Table 39 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ26x) (continued) Message ID Message Text Explanation and Recommended Actions YKZ264E MSG CON A YKLOGnn close error occurred. A close error occurred in YKLOG01 or YKLOG02. SC=0 RC=0 (rc=nnn, cp=xxx:yyy) YKLOGnn YKLOG01 or YKLOG02...
Page 155
Table 39 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ26x) (continued) Message ID Message Text Explanation and Recommended Actions YKZ267E MSG CON A YKLOGnn DEVTYPE macro error An error occurred in the DEVTYPE macro for SC=0 RC=0 occurred.
Page 156
Table 40 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ27x) Message ID Message Text Explanation and Recommended Actions YKZ270E MSG SC=36 Duplicate logical paths exist. The logical path definitions for index1 and index2 RC=36 (index1, index2) are duplicated.
Page 157
Table 40 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ27x) (continued) Message ID Message Text Explanation and Recommended Actions YKZ273E MSG SC=36 No path to be operated exist within No paths to be operated exist within the range RC=36 the range specified by the supplied specified by the parameter.
Page 158
Table 40 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ27x) (continued) Message ID Message Text Explanation and Recommended Actions YKZ276E MSG SC=36 Some of the arrays do not support A storage system using a path-controlled device or RC=36 storage system type paths.
Page 159
Table 41 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ28x) (continued) Message ID Message Text Explanation and Recommended Actions YKZ281E MSG SC=36 Some of the storage systems do not The device specified during command device usage RC=36 (Storage support Remote Control.
Page 160
Table 41 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ28x) (continued) Message ID Message Text Explanation and Recommended Actions YKZ284T MSG SC=36 CAJ value null or invalid. Cnt Ac-J Z_MirrorID in the copy group structure RC=36 is either NULL or invalid.
Page 161
Table 42 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ29x) Message ID Message Text Explanation and Recommended Actions YKZ290E MSG SC=48 FROMCU() exceeds number of CU The FROMCU has exceeded the maximum number of RC=48 that storage systems supported. CUs that are supported by storage systems.
Page 162
Table 42 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ29x) (continued) Message ID Message Text Explanation and Recommended Actions YKZ294E MSG CON An error occurred while acquiring An error occurred while acquiring the &YKLOGPT SC=0 RC=0 the system symbol &YKLOGPT.
Page 163
Table 42 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ29x) (continued) Message ID Message Text Explanation and Recommended Actions YKZ296E MSG SC=44 A JNLG is not registered in EXCTG. The journal group is not registered in EXCTG. RC=44 (JNLG=jj, MIRROR=m, EXCTG=e, The journal group registration to EXCTG might have...
Page 164
Table 42 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ29x) (continued) Message ID Message Text Explanation and Recommended Actions JNLG (string) The journal type not being registered (the journal type of the definition, rather than of the storage system) R-JNL: Journal of the secondary site...
Page 165
Table 42 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ29x) (continued) Message ID Message Text Explanation and Recommended Actions Y0KZ297E MSG SC=44 An error occurred while adding An error occurred while registering the journal group RC=44 JNLG to EXCTG.
Page 166
Table 42 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ29x) (continued) Message ID Message Text Explanation and Recommended Actions YKZ299E MSG SC=36 Definition of xxxxxxxx does not EXCTG information defined in the copy group and RC=36 match the actual configuration.
Page 167
The task is not authorized to execute a CLI command. the request. The program will terminate abnormally with user completion code 128. For details about how to set CLI command execution permissions, see the HP StorageWorks P9000 for Business Continuity Manager Software Reference Guide. List of Messages...
Page 168
Issued CLI command name Return code for the CLI command For details, see the command descriptions in the HP StorageWorks P9000 for Business Continuity Manager Software Reference Guide. YKZ320E TSO Supplied parameters invalid. An error was detected during parameter analysis.
Page 169
Table 43 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ3x) (continued) Message ID Message Text Explanation and Recommended Actions YKZ331E TSO RC=64 command terminated with an invalid The CLI command terminated with an invalid return return code. (r). code.
Page 170
Table 43 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ3x) (continued) Message ID Message Text Explanation and Recommended Actions YKZ352E TSO RC=16 The specified error code is invalid. The specified error code is invalid. A possible cause is as follows: The specified value is not a four-digit hexadecimal value.
Page 171
Table 44 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ40x) Message ID Message Text Explanation and Recommended Actions YKZ400E MSG SC=48 param parameter cannot be The parameter indicated by param cannot be RC=48 specified for copy-type Copy Group. specified for a copy group with a copy type of copy-type.
Page 172
Table 44 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ40x) (continued) Message ID Message Text Explanation and Recommended Actions YKZ404E MSG SC=36 Number of JNLG in the EXCTG The number of journal groups in the EXCTG RC=36 exceeds the limit.
Page 173
Table 44 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ40x) (continued) Message ID Message Text Explanation and Recommended Actions YKZ407E MSG SC=24 An error occurred during suspension RC=24 of CAJ ATTIME. (CT ID=ii, R-JNL=jj, GENID=gg, ATTSTS=aa, SISTS=ss, URSTS=uu, CODE=eeee, TIME=ATTIME-suspend-time) List of Messages 173...
Page 174
Table 44 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ40x) (continued) Message ID Message Text Explanation and Recommended Actions An error occurred while the suspend processing using the CAJ ATTIME suspend function was being performed. Check the error information, and remove the cause of the error.
Page 175
Table 44 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ40x) (continued) Message ID Message Text Explanation and Recommended Actions YYYYMMDD-HH:MM:SS.NNNNNN YYYY: Year MM: Month DD: Day HH: Hour MM: Minute SS.NNNNNN: Second List of Messages 175...
Page 176
Table 44 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ40x) (continued) Message ID Message Text Explanation and Recommended Actions YKZ408E MSG SC=24 An unexpected CAJ pair status RC=24 existed during suspension of CAJ ATTIME. (CT ID=ii, R-JNL=jj, GENID=gg, ATTSTS=aa, SISTS=ss, URSTS=uu, CODE=eeee, TIME=ATTIME-suspend-time)
Page 177
Table 44 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ40x) (continued) Message ID Message Text Explanation and Recommended Actions The status of the Cnt Ac-J Z copy pair was invalid while the suspend processing using the CAJ ATTIME suspend function was being performed.
Page 178
Table 44 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ40x) (continued) Message ID Message Text Explanation and Recommended Actions YYYY: Year MM: Month DD: Day HH: Hour MM: Minute SS.NNNNNN: Second YKZ409E MSG SC=24 The timeout limit expired during the The suspend processing started when the timeout RC=24 wait for the reservation time of the...
Page 179
Table 45 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ41x) Message ID Message Text Explanation and Recommended Actions YKZ410E MSG SC=36 Copygroup SUPFnc does not support You cannot use the Errorlevel attribute for this RC=36 CAJ Errorlevel. storage system.
Page 180
Table 45 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ41x) (continued) Message ID Message Text Explanation and Recommended Actions YKZ413E MSG SC=36 Copygroup SUPFnc does not support The timestamp transfer mode cannot be used with RC=36 the timestamp transfer mode.
Page 181
Table 45 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ41x) (continued) Message ID Message Text Explanation and Recommended Actions YKZ414E MSG SC=36 Copygroup SUPFnc does not support RC=48 parameter-name. List of Messages...
Page 182
Table 45 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ41x) (continued) Message ID Message Text Explanation and Recommended Actions The function indicated by parameter-name cannot be used. Use a device that supports the parameter-name function or configuration. Also, if scanning was not performed after the storage system microcode was replaced, perform another scan.
Page 183
Check the device address domain ID specified in the disk configuration definition file or the Set Defaults panel. For details about the NG scan, see the HP StorageWorks P9000 for Business Continuity Manager Software Reference Guide. devn (hexadecimal number) Device number defined in the...
Multi-line Messages Output to SYSTSPRT This section describes the multi-line messages that are output to SYSTSPRT. In this section, character strings enclosed in angle brackets (< >) are variables. YK8310I PRT COPY GROUP : <cgid> PREFIX : <prefix> DAD-ID : <dad> TYPE : <cgtype>...
<c>: Copy group host device address domain ID <d>: Copy group type <e>: Volume serial number <f>: Primary device number <g>: Copy direction >: Primary-to-secondary <: Secondary-to-primary <h>: Secondary device number <i>: Copy pair status <j>: Copy pair matching percentage <k>: Consistency group ID or master journal group ID <l>: Restore journal group ID <m>: Consistency delta value for each consistency group...
<e>: Consistency group ID <f>: Serial number of the primary storage system <g>: Serial number of the secondary storage system <h>: Sidefile threshold value <i>: Primary reserve sidefile cache-usage rate <j>: Primary reserve sidefile consistency cache-usage rate <k>: Primary write pending rate <l>: Secondary reserve sidefile cache-usage rate <m>: Secondary reserve sidefile consistency cache-usage rate <n>: Secondary write pending rate...
CYCLE TIME : <cycletime> WAITFOR TIMEOUT : <timeout> MSGLEVEL : <lvllog>, <lvlcons> ONACTIONERROR : <err-action> STOP AT STOPPOINT : <stoppt> SLEEP AT STOPPOINT : <sleeppt> The values specified in the YKMONOPT file are displayed. <cycletime>: Cycle time <timeout>: Timeout value <lvllog>: Level of messages to be output to SYSTSPRT <lvlcons>: Level of messages to be output to the console <err-action>: Error action to be executed...
Table 46 User Completion Codes Completion Code Explanation U0128 The user does not have the permission to execute CLI commands. If a reason code exists, it is displayed in the following format: XXYYZZZZ: XX: Lower 1 byte of SAF RC of the RACROUTE macro YY: Lower 1 byte of RACF RC of the RACROUTE macro ZZZZ: Lower 2 bytes of RACF Reason Code of the RACROUTE macro If the reason code is 00000040:...
2 Storage System Sense Byte Information This chapter describes storage system sense byte information (error codes) contained in messages that are output by Business Continuity Manager. Details of Error Codes This section lists the details on the storage system sense byte information (error codes) that are output to messages.
Page 190
Table 47 Details of Error Codes 20xx – 22xx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others The BC Z copy pair could not be Output Not output 2079 made because the specified S-VOL of BC Z copy pair is a part of a delta resync pair.
Page 191
Table 48 Details of Error Codes 23xx Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others The command could not be executed Output Not output 2301 because a BC Z program product has not been installed.
Page 192
Table 48 Details of Error Codes 23xx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others A BC Z copy pair cannot be Output Not output 231F resynchronized because the P-VOL is online.
Page 193
Table 48 Details of Error Codes 23xx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others A BC Z copy pair status cannot be Output Not output 2344 changed because the status of the copy pair does not allow the status transition.
Page 194
Table 48 Details of Error Codes 23xx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others A BC Z copy pair cannot be Output Not output 235D resynchronized with Reverse or Quick specified because the S-VOL is the P-VOL of a Cnt Ac-S Z or TCA copy pair that is not in the suspend status.
Page 195
Table 48 Details of Error Codes 23xx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others A BC Z copy pair cannot be Output Not output 2398 resynchronized (including Reverse) because the copy pair is not in the Split status.
Page 196
Table 48 Details of Error Codes 23xx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others The command could not be executed Output Not output 23F3 because the specified ATTIME suspend time is in the past. The command used to request that the Output Not output...
Page 197
Table 49 Details of Error Codes 36xx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others Registration to EXCTG has failed Not output Output Not output 3621 because the number of journal groups exceeded the maximum number that can be assigned to the specified arbitration command...
Page 198
Table 49 Details of Error Codes 36xx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others Registration to EXCTG has failed Not output Output Not output 3694 because the combination of the serial number and device on the specified arbitration command device is incorrect.
Page 199
Table 50 Details of Error Codes 37xx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others A Cnt Ac-J Z copy pair cannot be Not output Output Not output 370B resynchronized (with the DELTAJNL parameter) because the specified P-VOL is not in the HOLD status or HOLDTRNS status.
Page 200
Table 51 Details of Error Codes 46xx Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others A Cnt Ac-J Z copy pair cannot be Not output Output Not output 4600 made. Possible reasons include one or both of the following: The serial number of the primary storage system in the parameter...
Page 201
Table 51 Details of Error Codes 46xx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others Registration to or deletion from Not output Output Not output 460B EXCTG has failed because the specified arbitration command device number (uninstalled value), EXCTG ID, mirror ID, journal group...
Page 202
Table 51 Details of Error Codes 46xx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others The command device cannot be Not output Output Not output 461E defined. The reason might be one of the following: The command device is executing a remote control command.
Page 203
Table 51 Details of Error Codes 46xx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others A delta resync cannot be executed Not output Output Not output 4650 because volumes are specified within the operational range.
Page 204
Table 51 Details of Error Codes 46xx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others The CAJ ATTIME suspend time Not output Output Not output 466A cannot be set. The reason might be one of the following: The specified time is earlier than the consistency time.
Page 205
Table 52 Details of Error Codes 47xx – 49xx Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others A Cnt Ac-S Z or TCA copy pair Output Not output 47A3 cannot be suspended because output SVOL(PERMIT) or Reverse Resync is not supported.
Page 206
Table 53 Details of Error Codes 4Axx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others The C/T group ID defined in the Not output Output Not output 4A30 TCA copy group, and the C/T group ID set by the copy pair do not match.
Page 207
Table 53 Details of Error Codes 4Axx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others The command could not be executed Output Not output 4A8E because the status of the Cnt Ac-S Z output or TCA copy pair is being changed.
Page 208
Table 54 Details of Error Codes 4Bxx Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others A copy pair cannot be Output Not output 4B02 resynchronized because the copy output pair is in a status that cannot be changed.
Page 209
Table 54 Details of Error Codes 4Bxx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others A copy pair that is in a Cnt Ac-S Z Output Not output 4B09 copy group with a C/T group ID output specified cannot be dissolved because the copy pair status does...
Page 210
Table 54 Details of Error Codes 4Bxx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others RUN (releasing FREEZE) cannot be Output Not output 4B15 executed for a Cnt Ac-S Z copy output group with a C/T group ID specified.
Page 211
Table 54 Details of Error Codes 4Bxx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others No timestamp transfer mode Cnt Output Not output 4BB1 Ac-S Z copy pair can be made output because the specified volume is not a Cnt Ac-S Z copy pair.
Page 212
Table 55 Details of Error Codes 50xx – 6Axx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others The command device cannot be Not output Output Not output 64FB defined. The reason might be one of the following: The corresponding volume is not installed.
Page 213
Table 55 Details of Error Codes 50xx – 6Axx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others A path cannot be established Not output Output 69F2 because there is an invalid output parameter.
Page 214
Table 55 Details of Error Codes 50xx – 6Axx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others A copy pair cannot be made Output Not output 69FF because the program product necessary for the operation is not installed.
Page 215
Table 56 Details of Error Codes 7Fxx – 8Cxx Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others The command cannot be executed Not output Output 7F86 because no program product for copying is installed.
Page 216
Table 56 Details of Error Codes 7Fxx – 8Cxx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others The command could not be executed Not output Output 8CE8 because in the instruction to transfer to a remote DKC, there is an error in the parameter specification for the host command.
Page 217
Table 57 Details of Error Codes 8Dxx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others A copy pair cannot be made. The Output Not output Output 8D10 reason might be one of the output following: An inter-CU logical path has not...
Page 218
Table 57 Details of Error Codes 8Dxx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others A BC Z copy pair cannot be made Output Not output 8D16 or resynchronized. Possible reasons include one or more of the following: The status of the copy pair does...
Page 219
Table 57 Details of Error Codes 8Dxx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others A BC Z copy pair cannot be made Output Not output 8D1D or resynchronized. Possible reasons include one or more of the following: The S-VOL is online.
Page 220
Table 57 Details of Error Codes 8Dxx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others A BC Z copy pair cannot be Output Not output 8D26 suspended. Possible reasons include one or more of the following: The status of the copy pair does not allow the status transition.
Page 221
Table 57 Details of Error Codes 8Dxx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others A Cnt Ac-S Z or TCA copy pair Output Not output 8D29 cannot be suspended. Possible output reasons include one or more of the following:...
Page 222
Table 57 Details of Error Codes 8Dxx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others The serial numbers for the primary Not output Output 8D2C and the secondary storage systems in the host command parameter is incorrect.
Page 223
Table 57 Details of Error Codes 8Dxx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others The command device cannot be Not output Output Not output 8D45 defined. The reason might be one of the following: The corresponding volume is executing a remote control...
Page 224
Table 57 Details of Error Codes 8Dxx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others A BC Z copy pair cannot be Output Not output 8D56 dissolved. Possible reasons include one or more of the following: The status of the copy pair does not allow the status transition.
Page 225
Table 57 Details of Error Codes 8Dxx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others A Cnt Ac-S Z or TCA copy pair Output Not output 8D5A cannot be dissolved. Possible output reasons include one or more of the following:...
Page 226
Table 57 Details of Error Codes 8Dxx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others A TCA C/T group cannot be Not output Output Not output 8D71 registered or changed. Possible reasons include one or more of the following: The specified C/T group ID is...
Page 227
Table 57 Details of Error Codes 8Dxx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others The command could not be Not output Output 8DF2 executed because the specified volume is either not a TCA volume, or not the P-VOL.
Page 228
Table 58 Details of Error Codes 8Fxx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others A Cnt Ac-J Z copy pair cannot be Not output Output Not output 8F19 made because the emulation type of the specified volume cannot be used in Cnt Ac-J Z.
Page 229
Table 58 Details of Error Codes 8Fxx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others A Cnt Ac-J Z copy pair cannot be Not output Output Not output 8F2B made because the specified P-VOL is protected by the LDEV guard.
Page 230
Table 59 Details of Error Codes C0xx Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others The specified serial number or SSID Not output Output C023 of the primary storage system is output different from the storage system serial number or SSID of the local...
Page 231
Table 59 Details of Error Codes C0xx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others The serial number or SSID of the Output Not output C05A primary storage system in the Cnt output Ac-S Z or TCA parameter does not match the storage system serial...
Page 232
Table 59 Details of Error Codes C0xx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others The serial number or SSID of the Output Not output C073 secondary storage system in the output Cnt Ac-S Z or TCA parameter does not match the storage system serial...
Page 233
Table 60 Details of Error Codes C1xx Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others An attempt to establish a path has Not output Output C120 failed because the number of RCUs output registered in the MCU exceeds four.
Page 234
Table 60 Details of Error Codes C1xx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others The command could not be Not output Output C12C executed because automatic port output switching cannot be performed for the specified path.
Page 235
Table 60 Details of Error Codes C1xx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others The copy pair cannot be Output Not output C199 suspended. The reason might be output one of the following: The status of the bootup volume is being changed.
Page 236
Table 61 Details of Error Codes C2xx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others Copy pair resynchronization, Output Not output C28C which causes a copy direction output reversal, cannot be made because a path in the reverse copy direction is not set.
Page 237
Table 62 Details of Error Codes C3xx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others The specified volume within the Output Not output C30D RCU, or another volume which output belongs to the same group is in transition to a SIMPLEX or suspend status.
Page 238
Table 62 Details of Error Codes C3xx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others The RCU sequence (number, SSID Output Not output C324 or CU) is incorrect. output The RCU is not NVS ON. Output Not output C325...
Page 239
Table 62 Details of Error Codes C3xx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others The S-VOL is an S-VOL of another Output Not output C33B copy pair. output A copy pair cannot be made Output Not output C33C...
Page 240
Table 62 Details of Error Codes C3xx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others The cache for the MCU is being Output Not output C382 blocked on one side (in transition) output or it is being recovered on one side.
Page 241
Table 62 Details of Error Codes C3xx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others The Cnt Ac-S Z or TCA program Output Not output C3AE product has not been installed on output the RCU.
Page 242
Table 62 Details of Error Codes C3xx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others A copy pair could not be made Not output Output Not output C3C5 because there are multiple storage systems at the primary site, but the timer type is not System.
Page 243
Table 62 Details of Error Codes C3xx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others The S-VOL is not in the suspend Output Not output C3DB status. output A copy pair cannot be made Not output Output Not output...
Page 244
Table 63 Details of Error Codes CBxx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others A Cnt Ac-S Z or TCA copy pair Output Not output CB7E cannot be made because the CLPR output that the specified S-VOL belongs to differs from the one registered in...
Page 245
Table 64 Details of Error Codes DBxx – E8xx Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others A Cnt Ac-J Z copy pair status Not output Output Not output DB02 cannot be changed because the status transition is not allowed.
Page 246
Table 64 Details of Error Codes DBxx – E8xx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others A Cnt Ac-J Z copy pair cannot be Not output Output Not output E86B dissolved because the specified volume is not a Cnt Ac-J Z copy...
Page 247
Table 64 Details of Error Codes DBxx – E8xx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others A Cnt Ac-J Z copy pair cannot be Not output Output Not output E882 made because the emulation type for the volumes comprising the...
Page 248
Table 64 Details of Error Codes DBxx – E8xx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others A Cnt Ac-J Z copy pair cannot be Not output Output Not output E89B made because the status from the previous connection with another...
Page 249
Table 65 Details of Error Codes EAxx Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others The Cnt Ac-J Z copy pair cannot Not output Output Not output EA00 be operated for each EXCTG because of the following reasons: The JNLG specified in the copy group is not registered in the...
Page 250
Table 65 Details of Error Codes EAxx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others A Cnt Ac-J Z copy pair cannot be Not output Output Not output EA18 resynchronized because the copy pair is not in the suspend status.
Page 251
Table 65 Details of Error Codes EAxx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others A Cnt Ac-J Z copy pair cannot be Not output Output Not output EA36 suspended because the R-JNL group is not in the Active status.
Page 252
Table 65 Details of Error Codes EAxx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others A Cnt Ac-J Z copy pair cannot be Not output Output Not output EAA3 made because the charging limit of Cnt Ac-S Z in the RCU has been exceeded.
Page 253
Table 66 Details of Error Codes EBxx Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others A Cnt Ac-J Z copy pair status Not output Output Not output EB02 cannot be changed because the specified journal group number is invalid.
Page 254
Table 66 Details of Error Codes EBxx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others When making a copy pair using Not output Output Not output EB38 the same journal group number and mirror ID as an existing copy pair, you cannot specify a secondary storage system that...
Page 255
Table 66 Details of Error Codes EBxx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others A Cnt Ac-J Z copy pair cannot be Not output Output Not output EB4D made because the specified M-JNL group is not registered in the storage system.
Page 256
Table 66 Details of Error Codes EBxx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others A Cnt Ac-J Z copy pair cannot be Not output Output Not output EB62 made because the specified P-VOL is a command device.
Page 257
Table 66 Details of Error Codes EBxx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others A Cnt Ac-J Z copy pair cannot be Not output Output Not output EB7F made because the emulation type of the specified S-VOL is not supported.
Page 258
Table 66 Details of Error Codes EBxx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others A delta resync pair cannot be Not output Output Not output EBC6 made because the S-VOL of the specified copy pair is used by another program product (BC Z/FlashCopy).
Page 259
Table 66 Details of Error Codes EBxx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others A delta resync cannot be Not output Output Not output EBE1 executed because none of the S-VOLs of the delta resync pair are the S-VOLs of the other Cnt Ac-J Z.
HP StorageWorks P9000 for Business Continuity Manager Software Installation Guide HP StorageWorks P9000 for Business Continuity Manager Software Reference Guide A manual related to HP StorageWorks P9000 Command View Advanced Edition Software products: HP StorageWorks P9000 Replication Manager Software User Guide Manuals related to OS/390 and z/OS: Hitachi TrueCopy™...
Page 261
Hitachi ShadowImage™ for Mainframe User's Guide: HP XP24000 Disk Array, HP XP20000 Disk Array HP StorageWorks XP24000/XP20000 External Storage Software User’s Guide Manuals related to OS/390: MVS Programming: Assembler Services Guide, GC28- 1 762 MVS Setting Up a Sysplex, GC28- 1 779 MVS System Codes, GC28- 1 780 MVS System Commands, GC28- 1 781 MVS Programming: Assembler Services Reference, GC28- 1 910...
Typographic conventions Table 67 Document conventions Convention Element Blue text: Table 67 (page 263) Cross-reference links and e-mail addresses Blue, underlined text: http://www.hp.com Website addresses Bold text Keys that are pressed Text typed into a GUI element, such as a box GUI elements that are clicked or selected, such as menu and list items, buttons, tabs, and check boxes Italic text...
A generic name for the following products: P9000 for Business Continuity Manager Software HP StorageWorks P9000 for Business Continuity Manager Extended CT Group P9000 for Bus Continuity Manager Universal Replicator 4x4 Extended CT Software Command control address. Channel status byte.
Page 265
M-JNL Master journal. Mainframe Agent HP Device Manager Mainframe Agent. Main control unit. Missing interrupt handler. P-VOL Primary volume. PPRC Peer-to-peer remote copy. Program status word. R-JNL Restore journal. RACF Resource access control facility. Remote control unit. RECFM Record format. REXX Restructured extended executor.
Page 266
z/Linux Linux on IBM System z. 266 Glossary...