Select Storage System Panel - HP StorageWorks P9000 Reference Manual

Business continuity manager software reference guide
Hide thumbs Also See for StorageWorks P9000:
Table of Contents

Advertisement

NOTE:
When Type is DKC, make sure that you enter the values for S/N, Model, and IFType.
PathID can be omitted. If PathID is not specified, 00 (hexadecimal number) is the default. If the
storage system is directly connected to the host, by entering values in CU and CCA, you can specify
the device to which I/O is issued during operations on the paths. You do not need to specify SSID.
When Type is CU, make sure that you enter the values for S/N, Model, IFType, CU, and SSID. If
the storage system is directly connected to the host, by entering a value in CCA, you can specify
the device to which I/O is issued during operations on the paths. If the storage system is not directly
connected to the host and CCA is not specified, execution of the YKQRYPTH command will result
in an error. To avoid this, make sure that you enter a value for CCA. You do not need to specify
PathID.
If the storage system is directly connected to the host, you must enter the values for S/N, Model,
IFType, CU, SSID, and CCA for the scanned storage system, the storage system defined in the disk
configuration definition file in the Discover HP Storage System panel.
:
If the storage system serial number, for which a Non Gen'ed volume has already been defined in
the path set definition file to be edited is specified for S/N, the command device will issue I/O
regardless of the specified values for CU and CCA.
"Relationship between a S/N value and values specified for CU and CCA" (page 65)
a relationship between a S/N value and values specified for CU and CCA, and the device to which
I/O will be issued:
Table 45 Relationship between a S/N value and values specified for CU and CCA
S/N value
A serial number of storage system that
includes Non Gen'ed volumes
Note that if a CU number and CCA for Non Gen'ed volumes are entered for CU and CCA, the
route list that includes storage system specified for S/N is required during path operations.
The Model and IFType might be blank if the storage system was selected from the Select Storage
System panel. If this is the case, enter a value for Model and IFType.
"Values to be entered for Model and IFType" (page 65)
and IFType. If values are already set, you do not need to change the values.
Table 46 Values to be entered for Model and IFType
Storage System
HP StorageWorks XP1024/XP128 Disk Array
HP StorageWorks XP12000/XP10000 Disk Array
HP StorageWorks XP24000/XP20000 Disk Array
HP StorageWorks P9500 Disk Array

Select Storage System Panel

If s is specified in AC in the Edit Logical Path Definition panel, the Select Storage System panel is
displayed with a list of storage systems obtained from the disk configuration definition file.
Figure 55 (page 66)
Values specified for CU and CCA
A CU number and CCA for Non
Gen'ed volumes
A CU number and CCA for Gen'ed
volumes
shows the Select Storage System panel.
Discover/Define Configuration Panel (Configuration File Definition)
Device to which I/O will be issued
A command device
shows the values to be entered for Model
Model
IFType
9900V
0405
USP
1111
USPV
2020
VSP
3030
describes
65

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xp p9500

Table of Contents