8. Trouble in the SET Position
Operations in the SET position cannot be carried out.
Cause 1:
Control Lock is not in the SET position.
Measure: Turn the Control Lock to the SET position using the Control Key.
Cause 2:
Condition for the programming is not satisfied.
Measure: Check the condition for the programming .
Cause 3:
Operation procedure is incorrect.
Measure: Check the operation procedure you attempted.

17. Specifications

Size ........................................................................... 460 mm (width) x 400 mm (depth) x 305 mm
Weight ...................................................................... 13.5 kg
Power Required ....................................................... 117V
Power Consumed .................................................... 19W
Ambient Temperature ............................................. 0 C to 40 C
Relative Humidity .................................................... 10% to 90% RH (non-condensing)
Size of Receipt and Journal Rolls ......................... 45 mm (width) x max. 80 mm (diameter)
Validation Slip Spec.
Number of Sheets ............ max. 2 sheets (original + duplicate)
Thickness ......................... Non-carbon Slip ........ 0.07 mm to 0.14 mm
Size .................................. 70 mm or more in height, 135 mm to 210 mm in width
* Use a slip which has no curl (especially on edges), no bend, no wrinkle.
Memory Protection
Long-lasting rechargeable lithium battery for memory protection.
Specifications are subject to change without notice.
(height including rubber feet)
(or 337 mm (height) when Customer's Display is popped
up.)
Carbon Slip ............... 0.14 mm or less for total thickness of original sheet and
duplicate sheet
- 57 -
10 %, 60Hz
10 %
20 % (operating), 9W
EO1-11126
MA-1350-1 SERIES
20 % (non-operating)