ERROR MESSAGES

Problem
Specifying with
The sensor pen has not been calibrated.
sensor pen cannot be
done accurately
The pen is being held differently than when it
was calibrated.
• This machine is equipped with a thread detection device. If the "Start/Stop" button is pushed before the
upper threading is done, the machine will not operate properly. Also, depending on the pattern selected,
the machine may feed the fabric even if the needle is raised. This is due to the needle bar release
mechanism. At these times, the machine will make a sound different from what is made during normal
sewing. This is not the sign of a malfunction.
• If the power is disconnected during sewing:
Turn the main power to OFF and unplug the machine.
If you restart the machine, follow the instructions for operating the machine correctly.

ERROR MESSAGES

If the machine is not properly set and the "Start/Stop" button is pressed, or if the operation procedure is
incorrect, the machine does not start. An alarm sounds and an error message is displayed on the LCD. If
an error message displays, follow the instructions in the message.
Below is an explanation of error messages. Refer to these when necessary (if you press
operation correctly while the error message is displayed, the message disappears).
• Be sure to rethread the machine. If you press the "Start/Stop" button without rethreading the machine,
the thread tension may be wrong or the needle may break and cause injury.
Marks
A malfunction occurred.Turn the machine off, then on again.
Attach the embroidery frame.
Check and rethread the upper thread.
Data volume is too large for this pattern.
Failed to save file.
Lower the presser foot lever.
Move the sensor pen away from the currently marked position. This message appears when you press down the sensor pen
A-22
Cause
CAUTION
CAUTION
Error Messages
Solution
Before using the sensor pen for the first time,
be sure to calibrate it.
When using the sensor pen, be sure to hold it
at the same angle as when it was calibrated.
The specification location may be misaligned
if the pen is held at a slightly different angle.
In this case, make fine adjustments after
making the selection.
Cause/Solution
This message is displayed if some malfunction occurs.
This message appears if the embroidery frame is not attached
when you press
in the embroidery screen. (see page
B-58)
This message is displayed when the upper thread is broken or
not threaded correctly, and the "Start/Stop" button is pressed.
This message is displayed when the patterns you are editing
take up too much memory, or if you are editing too many
patterns for the memory.
This message appears when you try to save more than 100
settings screen image files in the USB media. In this case,
delete a file from the USB media or use different USB media.
(see page B-28)
This message is displayed when the "Presser Foot Lifter"
button is pushed while the presser foot lever is raised/the
needle is lowered.
tip before pressing
and keep pressing for the certain
period. Move the sensor pen away from the current position.
Page
B-56
B-56
or do the