Table 5. Abbreviated list of POST error codes (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See the parts listing in the Hardware Maintenance Manual to determine which components are customer
replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Error code
I9990301
70
ThinkServer TD100 and TD100x Types 4203, 4204, 4205, 4206, 6398, 6399, 6419, and 6429: Installation Guide
Description
Hard disk drive boot sector error.
Action
1. Reseat the following components,
depending on the server model:
v Hot-swap and non-hot-swap models:
a. Hard disk drive
b. Hard disk drive cable
c. Optional adapter cable
v Simple-swap models:
a. Hard disk drive
b. Hard disk drive cable
c. Optional adapter cable
2. Replace the following components one at
a time, depending on the server model,
in the order shown, restarting the server
each time:
v Hot-swap and non-hot-swap models:
a. Hard disk drive
b. Hard disk drive cable
c. Optional adapter cable
d. SAS/SATA backplane
v Simple-swap models:
a. Hard disk drive
b. Hard disk drive cable
c. SATA backplate
3. (Trained service technician only) Replace
the system board.