HP ProLiant DL388 User Manual: Hot-plug Fans

Hp proliant dl388 g7 server user guide.
Hide thumbs

Advertisement

LED3 pattern
One blink per
second
Steady glow
One blink per
second

Hot-plug fans

CAUTION:
and 6 in a single-processor configuration.
The only two valid fan configurations are listed in the following table.
Configuration
1 processor
2 processors
LED4 pattern
Interpretation
One blink per
The battery pack is below the minimum charge level and is being
second
charged. Features that require a battery (such as write cache, capacity
expansion, stripe size migration, and RAID migration) are temporarily
unavailable until charging is complete. The recharge process takes
between 15 minutes and two hours, depending on the initial capacity
of the battery.
Steady glow
The battery pack is fully charged, and posted write data is stored in the
cache.
Off
The battery pack is fully charged, and there is no posted write data in
the cache.
One blink per
An alternating green and amber blink pattern indicates that the cache
second
microcontroller is executing from within its boot loader and receiving
new flash code from the host controller.
There is a short circuit across the battery terminals or within the battery
pack. BBWC features are disabled until the battery pack is replaced.
The life expectancy of a battery pack is typically more than three
years.
There is an open circuit across the battery terminals or within the
battery pack. BBWC features are disabled until the battery pack is
replaced. The life expectancy of a battery pack is typically more than
three years.
To avoid damage to server components, fan blanks must be installed in fan bays 5
Fan bay 1 Fan bay 2 Fan bay 3
Fan
Fan
Fan
Fan
Fan bay 4 Fan bay 5 Fan bay 6
Fan
Fan
Fan
Fan
Fan blank
Fan blank
Fan
Fan
Component identification 22