Electrical
Connections
Motor Specifications
The AC motor used on this saw is a capaci-
tor-start, non-reversible
type. The models
covered in this manual have the following
specifications:
Specification:
Model
Model
Model
113.196221
113.196321
113.196421
Rated H.R
1.5
1.5
1.5
Max Developed
H.R
2.5
2.75
3.0
Voltage
120
120/240
120/240
Amperes
l 1
12/6
13/6.5
Hertz (cycles)
60
60
60
Phase
single
single
single
RPM
3450
3450
3450
,arbor Shall Rotation
clockwise
clockwise
clockwise
Run Capacitor
No
No
Yes
Note:
If saw does not start when switched
on, immediately
turn saw off and refer to
Troubleshooting.
Leaving
the switch
on will
destroy
the motor.
,_
WARNING
If not properly
grounded,
this power
tool could
cause
electrical
shock,
particularly
when
used
in damp
locations.
_IL WARNING
If electrical
shock
occurs,
your
reaction to shock could bring hands
into contact with blade.
_,WARNING
To avoid
electric
shock
or fire,
immediately
replace
worn,
cut, or
damaged
power cord.
The unit is wired for 120V and has a plug
that looks like this:
3-Prong
Plug
Grounding
Prong
Properly
Grounded
Outlet
Power Supply
,_
WARNING
Saw is factory
wired for 120V opera-
tion.
Connect
to
120V,
15-AMP
branch
circuit
and use 15-AMP time
delay fuse or circuit
breaker.
Failure
to connect
in this way could
result
in injury
from shock
or fire.
The saw must be properly grounded.
Not all
outlets are properly grounded.
If you are not
sure that your outlet is properly grounded,
have it checked by a qualified electrician.
The power tool is equipped with a 3-conduc-
tor cord and grounding type plug listed by
Underwriters'
Laboratories.
The ground
conductor has a green jacket and is attached
to the too! housing at one end and to the
ground prong in the attachment plug at the
other end.
The plug requires
a mating
3-conductor
grounded type outlet as shown above. If you
have an outlet that is of the 2-prong type, it
is recommended
that you have a qualified
electrician
replace it with a properly ground-
ed 3-prong outlet.