ELECTRICAL
_k Disconnect
power
before
working
on pump,
motor,
pressure
switch,
or wiring.
Your Motor
Terminal
Board (under
the motor
end cover)
and
Pressure
Switch
look like one of those shown
below.
Convert
to
115 Volts as shown.
Do not change
motor wiring
if line voltage
is
230 Volt to tl 5 Volt Conversion, Plug-in Type:
1. Pull plug
2. Plug in again
straight
with arrow
out from
on plug
terminal
pointing to
board.
'115 Volts'.
I
230 Volts or if you have a single voltage
motor.
Connect
power
supply as shown
for your type of switch
and your supply voltage.
i-Motor
, wires connect here.
wJree
CONnecthere.
230 Volt: Connect 2 hot wires black and red
here and cap the wh te neutral) wire. t does
not matter which wire goes to which screw,
115 Volt: Connect one hot wire (black or red)
to one of these screws (it doesn't matter
which one). Connect the white (neutral) wire
• to the other screw. Cap any remaining
230 Volt to 115 Volt Conversion, Spade Connector Type:
1.Move black wire
2. Move white wire
from A to LI.
with black tracer
from B to A.
tt
it
2.t _'.
3. Change Complete:
Ground
3few
Clamp the power cable to prevent strain
on the terminal screws.
Connect the green (or bare copper) ground wire
to the green ground screw.
Motor wires connect here.
-Power
supply wires connect here.
230 Volt: Connect 2 hot wires (black and red
here and cap the wh te neutra) w re. t does
not matter which wire goes to which screw,
115 Volt: Connect one hot wire (black or red)
to one of these screws (it doesn't matter
which one). Connect the white (neutral) wire
to the other screw. Cap any remaining
. black or red wires.
prevent strain
on the terminal screws.
- Connectthe green (or bare copper) groundwire
to the greengroundscrew.
31870398
Figure 4: Motor wiring connections through Pressure Switch. Match motor voltage to line voltage.
[ _.WARNING_ Hazardous
voltage.
Can
shock,
burn,
or kill
Connect
ground
wire
before
connecting
power
supply
wires.
Use the wire size (including
the
ground
wire)
speci-
fied in the wiring
chart. If possible,
connect
the pump
to a sep-
arate branch
circuit with no other appliances
on it.
[ _.WARNING_
Explosion
hazard.
Do not ground
to a gas sup-
ply line.
WIRING
CONNECTIONS
[_,WARNINGJ
Fire hazard.
Incorrect voltage
can cause a fire or
seriously
damage
the motor
and voids the wan_nty.
The supply
voltage
must be within
± 10% of the motor
nameplate
voltage.
NOTICE: Dual-voltage
motors are factory wired for 230 volts. If nec-
essary, reconnect
the motor for 115 volts, as shown.
Do not alter
the wiring in single voltage
motors.
Install, ground,
wire, and maintain
your pump
in compliance
with
the National
Electrical
Code (NEC) or the Canadian
Electrical
Code
(CEC), as applicable,
and with all local codes and ordinances
that
apply. Consult
your local building
inspector
for code information.
Connection
Procedure:
1.
Connect
the ground
vdre
first as shown
in Figure 4_ The
ground wire must be a sold copper
wife at least as large as the
power
supply wires.
2.
There must be a sofid metal connection
between
the pressure
switch
and the motor for motor grounding
protection.
If the
pressure
switch
is not connected
to the motor,
connect
the
green ground
screw
in the switch to the green ground
screw
under the motor end cover. Use a solid copper
wire at least as
large as the power
supply wires.
3.
Connect
the ground wire to a grounded
lead in a service panel,
to a metal undeeground
water
pipe, to a metal well ca_mg at
least ten feet (3M) long, or to a ground
electrode
provided
by
the power
company
or the hydro authority.
4.
Connect
the power
supply
wires
to the pressure
switch
as
shown
in Figure 4.
6