Pxie, 6 1/2-digit, +/-300 v, onboard 1.8 ms/s isolated digitizer, l and c measurement support, pxi digital multimeter (28 pages)
Summary of Contents for National Instruments NI PXI-562X
Page 1
Computer-Based Instruments NI PXI-562x User Manual High-Speed Frequency-Domain Digitizer NI PXI-562x User Manual July 2002 Edition Part Number 322949C-01...
Page 3
The reader should consult National Instruments if errors are suspected. In no event shall National Instruments be liable for any damages arising out of or related to this document or the information contained in it.
Page 4
Classification requirements are the same for the Federal Communications Commission (FCC) and the Canadian Department of Communications (DOC). Changes or modifications not expressly approved by National Instruments could void the user’s authority to operate the equipment under the FCC Rules.
Page 5
Canadian Department of Communications This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. Cet appareil numérique de la classe B respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada. Compliance to EU Directives Readers in the European Union (EU) must refer to the Manufacturer’s Declaration of Conformity (DoC) for information** pertaining to the CE Mark compliance scheme.
Related Documentation The following documents contain information that you might find helpful as you read this manual: • NI PXI-5620 Specifications • NI PXI-5621 Specifications • NI-SCOPE User Manual • Spectral Measurements Toolset User Guide NI PXI-562x User Manual ni.com...
Figure 1-1. PXI Installation Configuring and Testing the Digitizer To configure and test your NI 562x, complete the following steps: Launch Measurement & Automation Explorer. Double-click Devices and Interfaces to open a list of recognized devices. NI PXI-562x User Manual ni.com...
Misuse of the product can result in a hazard. You can compromise the safety protection built into the product if the product is damaged in any way. If the product is damaged, return it to National Instruments for repair. Do not substitute parts or modify the product except as described in this document.
10 MHz, AC-coupled reference input. The SMB connector, PFI1, is for external digital triggers. 562x 64 MS/s Digitizer INPUT +20 dBm MAX REF CLK IN +16 dBm MAX PFI 1 Figure 2-2. NI 562x Front Panel NI PXI-562x User Manual ni.com...
NI 562x continues to acquire posttrigger samples if you have specified a posttrigger sample count. The acquired samples are placed into onboard memory. The number of posttrigger or pretrigger samples is limited only by the amount of onboard memory. NI PXI-562x User Manual ni.com...
If, however, the record length is less than 80 µs, the dead time is 80 µs. During this time, the memory controller sets up for the next record. Also, additional dead time may exist while the minimum number of pretrigger samples are being acquired. NI PXI-562x User Manual ni.com...
NI 562x to phase lock to the system reference clock. • SMA connector (REF CLK IN)—A 10 MHz reference input that you can use to connect an external frequency source for synchronization. NI PXI-562x User Manual ni.com...
Technical Support and Professional Services Visit the following sections of the National Instruments Web site at for technical support and professional services: ni.com • Support—Online technical support resources include the following: – Self-Help Resources—For immediate answers and solutions, visit our extensive library of technical support resources available in English, Japanese, and Spanish at .